1001 |
[Leading Edge Registration] Leading Edge Registration Adjustment (Tray Location, Paper Type, Color Mode), Paper Type -> Plain, Thick 1or Thick 2 |
||
Adjusts the leading edge registration by changing the registration motor operation timing for each mode. |
|||
002 |
Tray: Plain |
*ENG |
[–9 to 9 / 0.0 / 0.1 mm/step] |
003 |
Tray: Middle Thick |
*ENG |
|
004 |
Tray: Thick 1 |
*ENG |
|
005 |
Tray: Thick 2 |
*ENG |
|
007 |
By-pass: Plain |
*ENG |
|
008 |
By-pass: Middle Thick |
*ENG |
|
009 |
By-pass: Thick 1 |
*ENG |
|
010 |
By-pass: Thick 2 |
*ENG |
|
011 |
By-pass: Thick 3 |
*ENG |
|
013 |
Duplex: Plain |
*ENG |
[–9 to 9 / 0.0 / 0.1 mm/step] |
014 |
Duplex: Middle Thick |
*ENG |
|
015 |
Duplex: Thick 1 |
*ENG |
|
016 |
Tray: Thick 3 |
*ENG |
|
017 |
Tray: Plain:1200 |
*ENG |
|
018 |
Tray: Middle Thick:1200 |
*ENG |
|
019 |
Tray: Thick 1:1200 |
*ENG |
|
020 |
By-pass: Plain:1200 |
*ENG |
|
021 |
By-pass: Middle Thick:1200 |
*ENG |
|
022 |
By-pass: Thick 1:1200 |
*ENG |
|
023 |
Duplex: Plain:1200 |
*ENG |
|
024 |
Duplex: Middle Thick:1200 |
*ENG |
|
025 |
Duplex: Thick 1:1200 |
*ENG |
1002 |
[Side to Side Reg.] Side-to-Side Registration Adjustment |
||
Adjusts the side-to-side registration by changing the laser main scan start position for each mode. |
|||
001 |
By-pass Table |
*ENG |
[–4 to 4 / 0.0 / 0.1 mm/step] |
002 |
Paper Tray 1 |
*ENG |
|
003 |
Paper Tray 2 |
*ENG |
|
004 |
Paper Tray 3 |
*ENG |
|
005 |
Paper Tray 4 |
*ENG |
|
006 |
Duplex |
*ENG |
|
007 |
Paper Tray 5 |
*ENG |
|
008 |
Large Capacity Tray |
*ENG |
1003 |
[Paper Buckle] Paper Buckle Adjustment (Tray Location, Paper Type), Paper Type: N: Normal, TH: Thick |
||
Adjusts the amount of paper buckle at the registration roller by changing the paper feed timing. |
|||
002 |
Paper Tray1: Plain |
*ENG |
[–9 to 5 / -2 / 1 mm/step] |
003 |
Tray1: Middle Thick |
*ENG |
[–9 to 5 / -1 / 1 mm/step] |
004 |
Paper Tray1: Thick1 |
*ENG |
[–9 to 5 / -2 / 1 mm/step] |
007 |
Paper Tray2/3/4/5/LCT: Plain |
*ENG |
|
008 |
Tray 2/3/4/5/LCT: Middle Thick |
*ENG |
[–9 to 5 / -1 / 1 mm/step] |
009 |
Paper Tray2/3/4/5/LCT: Thick 1 |
*ENG |
[–9 to 5 / -2 / 1 mm/step] |
012 |
By-pass: Plain |
*ENG |
[–9 to 5 / 0 / 1 mm/step] |
013 |
By-pass: Middle Thick |
*ENG |
|
014 |
By-pass: Thick 1 |
*ENG |
[–9 to 5 / -2 / 1 mm/step] |
018 |
Duplex: Plain |
*ENG |
[–9 to 5 / 0 / 1 mm/step] |
019 |
Duplex: Middle Thick |
*ENG |
|
020 |
Duplex: Thick 1 |
*ENG |
[–9 to 5 / -2 / 1 mm/step] |
021 |
Paper Tray1: Plain: 1200 |
*ENG |
[–9 to 5 / 0 / 1 mm/step] |
022 |
Tray1: Middle Thick: 1200 |
*ENG |
|
023 |
Tray 2/3/4/5LCT: Plain: 1200 |
*ENG |
|
024 |
Tray 2/3/4/5LCT: Mid: 1200 |
*ENG |
|
025 |
By-pass: Plain: 1200 |
*ENG |
|
026 |
By-pass: Middle Thick: 1200 |
*ENG |
|
030 |
Duplex: Plain: 1200 |
*ENG |
[–9 to 5 / 0 / 1 mm/step] |
031 |
Duplex: Middle Thick: 1200 |
*ENG |
1007 |
[By-Pass Size Detection] By-Pass Size Detection Display |
||
001 |
LG |
*ENG |
[0 or 1 / 0 / 1 ] 0: OFF, 1: ON |
Enables or disables the automatic paper size detection function of the by-pass tray. This SP determines what paper size the machine detects if the detected size is less than 8.5". 0: OFF (Letter/SEF), 1: ON (Legal/SEF) |
1101 |
[Reload Permit Setting] |
||
Specifies the settings of the reload permit for cold temperature in color mode. |
|||
001 |
Pre-rotation Start Temp. |
*ENG |
[0 to 200 / 0 / 1 deg/step] |
Specifies the pre-rotation start temperature. |
|||
002 |
Reload Target Temp.:Center |
*ENG |
[120 to 180 / 150 / 1 deg/step] |
Specifies the reload target temperature of the heating roller. |
|||
003 |
Reload Target Temp.:Press |
*ENG |
[0 to 200 / 120 / 1 deg/step] |
Specifies the reload target temperature of the pressure roller. |
|||
004 |
Temp.:Delta:Cold:Center |
*ENG |
[0 to 200 / 5 / 1 deg/step] |
Specifies the temperature correction of the heating roller (center) when the fusing unit is determined as cold state. |
|||
005 |
Temp.:Delta:Cold:End |
*ENG |
[40 to 200 / 100 / 1 deg/step] |
Specifies the temperature correction of the heating roller (end) when the fusing unit is determined as cold state. |
|||
006 |
Temp.:Delta:Cold:Press |
*ENG |
[0 to 200 / 65 / 1 deg/step] |
Specifies the temperature correction of the pressure roller when the fusing unit is determined as cold state. |
|||
007 |
Time:Cold |
*ENG |
[0 to 100 / 30 / 1 sec/step] |
Specifies the threshold time for the fusiing reload when the fusing unit is determined as cold state. |
|||
008 |
Temp.:Delta:Warm:Center |
*ENG |
[0 to 200 / 5 / 1 deg/step] |
Specifies the temperature correction of the heating roller (center) when the fusing unit is determined as warm state. |
|||
009 |
Temp.:Delta:Warm:End |
*ENG |
[40 to 200 / 100 / 1 deg/step] |
Specifies the temperature correction of the heating roller (end) when the fusing unit is determined as warm state. |
|||
010 |
Temp.:Delta:Warm:Press |
*ENG |
[0 to 200 / 65 / 1 deg/step] |
Specifies the temperature correction of the pressure roller when the fusing unit is determined as warm state. |
|||
011 |
Time:Warm |
*ENG |
[0 to 100 / 30 / 1 sec/step] |
Specifies the threshold time for the fusing reload when the fusing unit is determined as warm state. |
|||
012 |
Temp.:Delta:Hot:Center |
*ENG |
[0 to 200 / 5 / 1 deg/step] |
Specifies the temperature correction of the heating roller (center) when the fusing unit is determined as hot state. |
|||
013 |
Temp.:Delta:Hot:End |
*ENG |
[40 to 200 / 100 / 1 deg/step] |
Specifies the temperature correction of the heating roller (end) when the fusing unit is determined as hot state. |
|||
014 |
Temp.:Delta:Hot:Press |
*ENG |
[0 to 200 / 65 / 1 deg/step] |
Specifies the temperature correction of the pressure roller when the fusing unit is determined as hot state. |
|||
015 |
Time:Hot |
*ENG |
[0 to 100 / 30 / 1 sec/step] |
Specifies the threshold time for the fusing reload when the fusing unit is determined as hot state. |
|||
016 |
Temp.:Delta:Cold:BW:Center |
*ENG |
[0 to 200 / 15 / 1 deg/step] |
Specifies the temperature correction of the heating roller (center) in the black and white mode when the fusing unit is determined as cold state. |
|||
017 |
Temp.:Delta:Cold:BW:End |
*ENG |
[40 to 200 / 100 / 1 deg/step] |
Specifies the temperature correction of the heating roller (end) in the black and white mode when the fusing unit is determined as cold state. |
|||
018 |
Temp.Delta:Cold:BW:Press |
*ENG |
[0 to 200 / 70 / 1 deg/step] |
Specifies the temperature correction of the pressure roller in the black and white mode when the fusing unit is determined as cold state. |
|||
019 |
Time:Cold:BW |
*ENG |
[0 to 100 / 30 / 1 sec/step] |
Specifies the threshold time for the fusing reload in black and white mode when the fusing unit is determined as cold state. |
|||
020 |
Temp.:Delta:Cold:BW2:Center |
*ENG |
[0 to 200 / 15 / 1 deg/step] |
Specifies the temperature correction of the heating roller (center) in the black and white mode when the fusing unit is determined as warm state. |
|||
021 |
Temp.:Delta:Cold:BW2:End |
*ENG |
[40 to 200 / 100 / 1 deg/step] |
Specifies the temperature correction of the heating roller (end) in the black and white mode when the fusing unit is determined as warm state. |
|||
022 |
Temp.Delta:Cold:BW2:Press |
*ENG |
[0 to 200 / 100 / 1 deg/step] |
Specifies the temperature correction of the pressure roller in the black and white mode when the fusing unit is determined as warm state. |
|||
023 |
Time:Cold:BW2 |
*ENG |
[0 to 100 / 30 / 1 sec/step] |
Specifies the threshold time for the fusing reload in black and white mode when the fusing unit is determined as warm state. |
1102 |
[Feed Permit Setting] |
||
Specified the settings of the paper feeding timing. |
|||
001 |
Temp.:Lower Delta:Center |
*ENG |
[0 to 200 / 15 / 1 deg/step] |
Specifies the subtractive temperature of the heating roller (center) for the paper feed permission. |
|||
002 |
Temp.:Lower Delta:End |
*ENG |
[0 to 200 / 100 / 1 deg/step] |
Specifies the subtractive temperature of the heating roller (end) for the paper feed permission. |
|||
003 |
Temp.:Upper Delta:Center |
*ENG |
[0 to 200 / 100 / 1 deg/step] |
Specifies the additional temperature of the heating roller (center) for the paper feed permission. |
|||
004 |
Temp.:Upper Delta:End |
*ENG |
[0 to 200 / 100 / 1 deg/step] |
Specifies the additional temperature of the heating roller (end) for the paper feed permission. |
|||
005 |
Temp.:Lower Delta:Press |
*ENG |
[0 to 200 / 100 / 1 deg/step] |
Specifies the subtractive temperature of the pressure roller for the paper feed permission. |
|||
006 |
Rotation Time |
*ENG |
[0 to 100 / 0 / 1 sec/step] |
Specifies the threshold time of the pre-rotation for the paper feed permission. |
|||
007 |
Temp.:Lower Delta:Center:Sp.1 |
*ENG |
[0 to 200 / 5 / 1 deg/step] |
008 |
Temp.:Lower Delta:End:Sp.1 |
*ENG |
[0 to 200 / 100 / 1 deg/step] |
009 |
Temp.:Upper Delta:Center:Sp.1 |
*ENG |
[0 to 200 / 100 / 1 deg/step] |
010 |
Temp.:Upper Delta:End:Sp.1 |
*ENG |
[0 to 200 / 100 / 1 deg/step] |
011 |
Temp.:Lower Delta:Press:Sp.1 |
*ENG |
[0 to 200 / 60 / 1 deg/step] |
012 |
Rotation Time:Sp.1 |
*ENG |
[0 to 200 / 0 / 1 sec/step] |
013 |
Temp.:Lower Delta:Center:Sp.2 |
*ENG |
[0 to 200 / 5 / 1 deg/step] |
014 |
Temp.:Lower Delta:End:Sp.2 |
*ENG |
[0 to 200 / 100 / 1 deg/step] |
015 |
Temp.:Upper Delta:Center:Sp.2 |
*ENG |
[0 to 200 / 15 / 1 deg/step] |
016 |
Temp.:Upper Delta:End:Sp.2 |
*ENG |
[0 to 200 / 100 / 1 deg/step] |
017 |
Temp.:Lower Delta:Press:Sp.2 |
*ENG |
[0 to 200 / 100 / 1 deg/step] |
018 |
Rotation Time:Sp2 |
*ENG |
[0 to 100 / 0 / 1 sec/step] |
019 |
Feed Permit Time |
*ENG |
[0 to 200 / 120 / 1 sec/step] |
1105 |
[Print Target Temp] |
|||
(Printing Mode, Roller Type, [Color], Simplex/Duplex) Roller Type –> Center and Ends: Heating roller, Pressure –> Pressure roller Paper Type -> Plain, Thin, Thick, OHP, Middle Thick, Special |
||||
001 |
Plain1:FC:Center |
*ENG |
[120 to 200 / 155 / 1 deg/step] |
|
Specifies the heating roller target temperature for the ready condition in full color printing. |
||||
002 |
Plain1:FC:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
Specifies the pressure roller target temperature for the ready condition in full color printing.. |
||||
003 |
Plain1:BW:Center |
*ENG |
[120 to 200 / 145 / 1 deg/step] |
|
Specifies the heating roller target temperature for the ready condition in BW printing. |
||||
004 |
Plain1:BW:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
Specifies the pressure roller target temperature for the ready condition in BW printing. |
||||
005 |
Plain2:FC:Center |
*ENG |
[120 to 200 / 160 / 1 deg/step] |
|
Specifies the heating roller target temperature for the ready condition in full color printing. |
||||
006 |
Plain2:FC:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
Specifies the pressure roller target temperature for the ready condition in full coloe printing. |
||||
007 |
Plain2:BW:Center |
*ENG |
[120 to 200 / 150 / 1 deg/step] |
|
Specifies the heating roller target temperature for the ready condition in BW printing. |
||||
008 |
Plain2:BW:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
Specifies the pressure roller target temperature for the ready condition in BW printing. |
||||
009 |
Thin:FC:Center |
*ENG |
[120 to 200 / 150 / 1 deg/step] |
|
010 |
Thin:FC:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
011 |
Thin:BW:Center |
*ENG |
[120 to 200 / 140 / 1 deg/step] |
|
012 |
Thin:BW:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
013 |
M-thick:FC:Center |
*ENG |
[120 to 200 / 165 / 1 deg/step] |
|
014 |
M-thick:FC:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
015 |
M-thick:BW:Center |
*ENG |
[120 to 200 / 155 / 1 deg/step] |
|
016 |
M-thick:BW:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
017 |
Thick1:FC:Center |
*ENG |
[120 to 200 / 155 / 1 deg/step] |
|
018 |
Thick1:FC:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
019 |
Thick1:BW:Center |
*ENG |
[120 to 200 / 145 / 1 deg/step] |
|
020 |
Thick1:BW:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
021 |
Thick2:FC:Center |
*ENG |
[120 to 200 / 165 / 1 deg/step] |
|
022 |
Thick2:FC:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
023 |
Thick2:BW:Center |
*ENG |
[120 to 200 / 155 / 1 deg/step] |
|
024 |
Thick2:BW:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
025 |
Thick3:FC:Center |
*ENG |
[120 to 200 / 170 / 1 deg/step] |
|
026 |
Thick3:FC:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
027 |
Thick3:BW:Center |
*ENG |
[120 to 200 / 160 / 1 deg/step] |
|
028 |
Thick3:BW:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
029 |
Special1:FC:Center |
*ENG |
[120 to 200 / 160 / 1 deg/step] |
|
030 |
Special1:FC:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
031 |
Special1:BW:Center |
*ENG |
[120 to 200 / 150 / 1 deg/step] |
|
032 |
Special1:BW:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
033 |
Special2:FC:Center |
*ENG |
[120 to 200 / 155 / 1 deg/step] |
|
034 |
Special2:FC:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
035 |
Special2:BW:Center |
*ENG |
[120 to 200 / 145 / 1 deg/step] |
|
036 |
Special2:BW:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
037 |
Special3:FC:Center |
*ENG |
[120 to 200 / 165 / 1 deg/step] |
|
038 |
Special3:FC:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
039 |
Special3:BW:Center |
*ENG |
[120 to 200 / 155 / 1 deg/step] |
|
040 |
Special3:BW:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
041 |
Envelop:Center |
*ENG |
[120 to 200 / 180 / 1 deg/step] |
|
042 |
Envelop:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
101 |
Plain1:FC:Center:Low Speed |
*ENG |
[120 to 200 / 135 / 1 deg/step] |
|
102 |
Plain1:FC:Press:Low Speed |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
103 |
Plain1:BW:Center:Low Speed |
*ENG |
[120 to 200 / 135 / 1 deg/step] |
|
104 |
Plain1:BW:Press:Low Speed |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
105 |
Plain2:FC:Center:Low Speed |
*ENG |
[120 to 200 / 140 / 1 deg/step] |
|
106 |
Plain2:FC:Press:Low Speed |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
107 |
Plain2:BW:Center:Low Speed |
*ENG |
[120 to 200 / 135 / 1 deg/step] |
|
108 |
Plain2:BW:Press:Low Speed |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
109 |
M-thick:FC:Center:Low Speed |
*ENG |
[120 to 200 / 145 / 1 deg/step] |
|
110 |
M-thick:FC:Press:Low Speed |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
111 |
M-thick:BW:Center:Low Speed |
*ENG |
[120 to 200 / 140 / 1 deg/step] |
|
112 |
M-thick:BW:Press:Low Speed |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
113 |
Thick1:FC:Center:Low Speed |
*ENG |
[120 to 200 / 150 / 1 deg/step] |
|
114 |
Thick1:FC:Press:Low Speed |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
115 |
Thick1:BW:Center:Low Speed |
*ENG |
[120 to 200 / 145 / 1 deg/step] |
|
116 |
Thick1:BW:Press:Low Speed |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
117 |
Special1:FC:Center:Low Speed |
*ENG |
[120 to 200 / 135 / 1 deg/step] |
|
118 |
Special1:FC:Press:Low Speed |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
119 |
Special1:BW:Center:Low Speed |
*ENG |
[120 to 200 / 130 / 1 deg/step] |
|
120 |
Special1:BW:Press:Low Speed |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
121 |
Special2:FC:Center:Low Speed |
*ENG |
[120 to 200 / 150 / 1 deg/step] |
|
122 |
Special2:FC:Press:Low Speed |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
123 |
Special2:BW:Center:Low Speed |
*ENG |
[120 to 200 / 145 / 1 deg/step] |
|
124 |
Special2:BW:Press:Low Speed |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
125 |
Plain1:Glossy:Center |
*ENG |
[120 to 200 / 140 / 1 deg/step] |
|
126 |
Plain1:Glossy:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
127 |
Plain2:Glossy:Center |
*ENG |
[120 to 200 / 145 / 1 deg/step] |
|
128 |
Plain2:Glossy:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
129 |
M-thick:Glossy:Center |
*ENG |
[120 to 200 / 150 / 1 deg/step] |
|
130 |
M-thick:Glossy:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
131 |
OHP:Center |
*ENG |
[120 to 200 / 150 / 1 deg/step] |
|
132 |
OHP:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
133 |
Envelop:Center:Low Speed |
*ENG |
[120 to 200 / 170 / 1 deg/step] |
|
134 |
Envelop:Press:Low Speed |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
135 |
Thin:FC:Center:Low Speed |
*ENG |
[120 to 200 / 135 / 1 deg/step] |
|
136 |
Thin:FC:Press:Low Speed |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
137 |
Thin:BW:Center:Low Speed |
*ENG |
[120 to 200 / 130 / 1 deg/step] |
|
138 |
Thin:BW:Press:Low Speed |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
139 |
Thick4:FC:Center |
*ENG |
[120 to 200 / 175 / 1 deg/step] |
|
140 |
Thick4:FC:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
|
141 |
Thick4:BW:Center |
*ENG |
[120 to 200 / 165 / 1 deg/step] |
|
142 |
Thick4:BW:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
1106 |
[Fusing Temp. Display] |
||
001 |
Center |
- |
[-10 to 250 / - / 1 deg/step] Displays the temperature of the heating roller. |
002 |
End |
- |
|
003 |
Pressure |
- |
[-10 to 250 / - / 1 deg/step] Displays the temperature of the heating roller. |
004 |
Pressure End |
- |
1107 |
[Standby Target Temp. Setting] |
||
001 |
Standby Heater Off Time |
*ENG |
[0 to 100 / 15 / 1 sec/step] |
Specifies the time that the fusing heater turns off after the fusing unit temperature has reached its target temperature. |
|||
002 |
Stanby/Preheat1: Press |
*ENG |
[0 to 125 / 90 / 1 deg/step] |
Specifies the temperature of the pressure roller for the ready or energy save 1 mode. |
|||
004 |
Preheat2:Press |
*ENG |
[0 to 125 / 90 / 1 deg/step] |
Specifies the temperature of the pressure roller for the energy save 2 mode. |
|||
006 |
Low Power:Press |
*ENG |
[0 to 125 / 60 / 1 deg/step] |
Specifies the temperature of the pressure roller for the low power mode. |
|||
007 |
Print Ready:Center |
*ENG |
[120 to 180 / 150 / 1 deg/step] |
Specifies the temperature of the heating roller for the print ready condition. |
|||
008 |
Print Ready:Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
Specifies the temperature of the pressure roller for the print ready condition. |
1108 |
[After Reload/Job Target Temp.] |
||
001 |
Center |
*ENG |
[120 to 180 / 150 / 1 deg/step] |
Specifies the temperature of the heating roller after re-load or job. |
|||
002 |
Press |
*ENG |
[100 to 200 / 120 / 1 deg/step] |
Specifies the temperature of the pressure roller after re-load or job. |
1111 |
[Environment Correction:Fusing] |
||
001 |
Temp.: Threshold: Low |
*ENG |
[0 to 100 / 17 / 1 deg/step] |
Specifies the threshold temperature for low temperature. If the fusing temperature is 17°C or less, the machine executes the fusing mode for low temperature. |
|||
002 |
Temp.: Threshold: High |
*ENG |
[0 to 100 / 30 / 1 deg/step] |
Sepcifies the threshold temperature for high temperature. If the fusing temperature is 30°C or more, the machine executes the fusing mode for high temperature. |
|||
003 |
Low Temp. Correction |
*ENG |
[0 to 15 / 5 / 1 deg/step] |
Specifies the additional temperature for the target temperature. If the fusing temperature is in low temperature condition, this temperature is added to the taraget temperature. |
|||
004 |
High Temp. Correction |
*ENG |
[0 to 15 / 0 / 1 deg/step] |
Specifies the additional temperature for the target temperature. If the fusing temperature is in high temperature condition, this temperature is added to the taraget temperature. |
|||
005 |
Job Low Temp. Correction |
*ENG |
[0 to 100 / 5 / 0.1 deg/step] |
006 |
Job High Temp. Correction |
*ENG |
[0 to 100 / 0 / 0.1 deg/step] |
007 |
Job Low Temp. Correction:Sp. |
*ENG |
[0 to 100 / 10 / 0.1 deg/step] |
008 |
Job High Temp. Correction:Sp. |
*ENG |
[0 to 100 / 0 / 0.1 deg/step] |
1112 |
[Repeat Temperature Correction] |
|||
001 |
Control Time 1 |
*ENG |
[0 to 300 / 100 / 1 sec/step] |
|
Specifies the threshold time for entering the repeat temperature correction mode after the first sheet of paper has reached to the registration roller. |
||||
002 |
Control Time 2 |
*ENG |
[0 to 300 / 300 / 1 sec/step] |
|
Specifies the threshold time for entering the repeat temperature correction mode after the control time 1 (specified with SP1112-001) has elapsed. |
||||
003 |
Temp.:Plain:Center:1 |
*ENG |
[-15 to 15 / 0 / 0.1 deg/step] |
|
Specifies the correction temperature of the heating roller for plain paper when the operation time of the machine is in the interval between control time 1 and control time 2. |
||||
004 |
Temp.:Plain:Press:1 |
*ENG |
[-10 to 10 / 0 / 0.1 deg/step] |
|
Specifies the correction temperature of the pressure roller for plain paper when the operation time of the machine is in the interval between control time 1 and control time 2. |
||||
005 |
Temp.:Plain:Center:2 |
*ENG |
[-15 to 15 / -5 / 0.1 deg/step] |
|
Specifies the correction temperature of the heating roller for plain paper when the operation time of the machine is more than control time 2. |
||||
006 |
Temp.:Plain:Press:2 |
*ENG |
[-10 to 10 / 0 / 0.1 deg/step] |
|
Specifies the correction temperature of the pressure roller for plain paper when the operation time of the machine is more than control time 2. |
||||
007 |
Temp.:M-thick:Center:1 |
*ENG |
[-15 to 15 / -5 / 0.1 deg/step] |
|
Specifies the correction temperature of the heating roller for middle thick paper when the operation time of the machine is in the interval between control time 1 and control time 2. |
||||
008 |
Temp.:M-thick:Press:1 |
*ENG |
[-10 to 10 / 0 / 0.1 deg/step] |
|
Specifies the correction temperature of the pressure roller for middle thick paper when the operation time of the machine is in the interval between control time 1 and control time 2. |
||||
009 |
Temp.:M-thick:Center:2 |
*ENG |
[-15 to 15 / -5 / 0.1 deg/step] |
|
Specifies the correction temperature of the heating roller for middle thick paper when the operation time of the machine is more than control time 2. |
||||
010 |
Temp.:M-thick:Press:2 |
*ENG |
[-10 to 10 / 0 / 0.1 deg/step] |
|
Specifies the correction temperature of the pressure roller for middle thick paper when the operation time of the machine is more than control time 2. |
||||
011 |
Temp.:Others:Center:1 |
*ENG |
[-15 to 15 / 0 / 0.1 deg/step] |
|
Specifies the correction temperature of the heating roller for paper type other than plain and middle thick paper when the operation time of the machine is in the interval between control time 1 and control time 2. |
||||
012 |
Temp.:Others:Press:1 |
*ENG |
[-10 to 10 / 0 / 0.1 deg/step] |
|
Specifies the correction temperature of the pressure roller for other than palin and middle thick paper when the operation time of the machine is in the interval between control time 1 and control time 2. |
||||
[Image Processing Temp. Correct] |
||||
013 |
Temp.:Plain:Center: Level1 |
*ENG |
[-20 to 20 / 0 / 0.1 deg/step] |
|
Specifies the correction temperature for the level 1 of the job image control in black and white printing mode. |
||||
014 |
Temp.:Plain:Center: Level2 |
*ENG |
[-20 to 20 / 0 / 0.1 deg/step] |
|
Specifies the correction temperature for the level 2 of the job image control in black and white printing mode. |
1113 |
[Curl Correction] |
|||
001 |
Execute Pattern |
*ENG |
[0 to 2 / 0 / 1 /step] 0: Off, 1: On (No Decurl), 2: On |
|
Selects the curl correction type. 0: The curl correction is not done. 1: The curl correction is done only when paper is fed to the 1 bin tray. 2: The curl correction is always done. |
||||
002 |
Humidity:Threshold:M-humid |
*ENG |
[0 to 100 / 1 / 1 %/step] |
|
Specifies the threshold between low and middle humidity. |
||||
003 |
Humidity:Threshold:H-humid |
*ENG |
[0 to 100 / 65 / 1 %/step] |
|
Specifies the threshold between middle and high humidity. |
||||
004 |
Permit Temp.:Delta:Press:M-humid |
*ENG |
[0 to 200 / 60 / 1 deg/step] |
|
Specifies the threshold temperature for the curl control in middle humidity. |
||||
005 |
Permit Temp.:Delta:Press:H-humid |
*ENG |
[0 to 200 / 50 / 1 deg/step] |
|
Specifies the threshold temperature for the curl control in high humidity. |
||||
006 |
Permit Temp.:Delta:Press:M-humid:No Decurl |
*ENG |
[0 to 200 / 50 / 1 deg/step] |
|
Specifies the threshold temperature for the no curl control in middle humidity. |
||||
007 |
Permit Temp.:Delta:Press:H-humid:No Decurl |
*ENG |
[0 to 200 / 40 / 1 deg/step] |
|
Specifies the threshold temperature for the no curl control in high humidity. |
||||
008 |
CPM:M-humid |
*ENG |
[0 to 100 / 80 / 1 %/step] |
|
Specifies the CPM ratio of the decurl control against to the normal operation in middle humidity. |
||||
009 |
CPM:H-humid |
*ENG |
[0 to 100 / 65 / 1 %/step] |
|
Specifies the CPM ratio of the decurl control against to the normal operation in high humidity. |
||||
010 |
CPM:M-humid:No Decurl |
*ENG |
[0 to 100 / 80 / 1 %/step] |
|
Specifies the CPM ratio against of the no decurl control to the normal operation in middle humidity. |
||||
011 |
CPM:H-humid:No Decurl |
*ENG |
[0 to 100 / 65 / 1 %/step] |
|
Specifies the CPM ratio against of the no decurl control to the normal operation in high humidity. |
1114 |
[Heat Storage Status] |
||
001 |
Temp.:Threshold:Press |
*ENG |
[0 to 200 / 80 / 1 deg/step] |
Specifies the threshold temperature of the pressure roller for the heat storage status. |
|||
002 |
Temp.:Threshold:Atmosphere |
*ENG |
[0 to 200 / 60 / 1 deg/step] |
Specifies the threshold temperature inside the machine for the heat storage feedback control. |
1115 |
[Target Temp. Correction] |
||
001 |
Temp.:Delta:End |
*ENG |
[-100 to 100 / 0 / 1 deg/step] |
Specifies the different temperature between end and center of the heating roller. |
1116 |
[Heat Storage FB Control] |
|||
001 |
Execution mode |
*ENG |
[0 to 2 / 1 / 1 /step] 0: OFF, 1: ON (BW), 2: ON (BW/FC) |
|
Selects the heat storage FB control mode. |
||||
011 |
Time Out |
*ENG |
[0 to 500 / 5 / 1 sec/step] |
|
Specifies the no-entry time for the heat strorage FB control after the LD units have fired. |
||||
021 |
Delay:Standard Speed:FC:1 |
*ENG |
[0 to 20,000 / 3500 / 1 msec/step] |
|
022 |
Delay:Standard Speed:BW:1 |
*ENG |
[0 to 20,000 / 1400 / 1 msec/step] |
|
031 |
Delay:Standard Speed:FC:2 |
*ENG |
[0 to 20,000 / 3500 / 1 msec/step] |
|
032 |
Delay:Standard Speed:BW:2 |
*ENG |
[0 to 20,000 / 1400 / 1 msec/step] |
|
041 |
Press Reference Temp. |
*ENG |
[0 to 200 / 80 / 1 deg/step] |
|
Specifies the standard temperature for the pressure roller during the heat storage FB control. |
||||
042 |
Temp. Correction Lower Limit |
*ENG |
[-30 to 0 / -2 / 1 deg/step] |
|
Specifies the lower llimit temperature for the heat storage FB control. |
||||
043 |
Temp. Correction Upper Limit |
*ENG |
[0 to 30 / 0 / 1 deg/step] |
|
Specifies the upper llimit temperature for the heat storage FB control. |
||||
051 |
Paper Thickness Coefficient:Plain1 |
*ENG |
[0 to 100 / 20 / 1 /step] |
|
Specifies the additional temperatreu to the heat strage FB control for plain paper 1. |
||||
052 |
Paper Thickness Coefficient:Plain2 |
*ENG |
[0 to 100 / 20 / 1 /step] |
|
Specifies the additional temperatreu to the heat strage FB control for plain paper 2. |
1121 |
[Switch:Rotation Start/Stop] |
||
001 |
Time:After Reload |
*ENG |
[0 to 100 / 60 / 1 sec/step] |
Specifies the ON time of the pressure roler lamp after the fusing temperature has reached the reload temperature. |
|||
002 |
Time:After Recovery |
*ENG |
[0 to 100 / 15 / 1 sec/step] |
Specifies the ON time of the pressure roler lamp after the fusing temperature has reached the target temperature. |
|||
003 |
Time:After Job |
*ENG |
[0 to 100 / 0 / 1 sec/step] |
Specifies the ON time of the pressure roler lamp after the paper feeding has finished. |
|||
004 |
Press Temp.:After Reload |
*ENG |
[0 to 160 / 160 / 1 deg/step] |
Specifies the target temperature of the pressure roller center area after the fusing temperature has reached the reload temperature. |
|||
005 |
End Uniform Start Temp.:B4 |
*ENG |
[0 to 250 / 200 / 1 deg/step] |
Specifies the target temperature of the pressure roller end arear after the B4 paper feeding has finished. |
|||
006 |
End Uniform Start Temp.:A4 |
*ENG |
[0 to 250 / 185 / 1 deg/step] |
Specifies the target temperature of the pressure roller end arear after the A4 paper feeding has finished. |
|||
007 |
End Uniform Start Temp.:A5 |
*ENG |
[0 to 250 / 170 / 1 deg/step] |
Specifies the target temperature of the pressure roller end arear after the A5 paper feeding has finished. |
|||
008 |
Overshoot Prevent Temp. |
*ENG |
[0 to 250 / 220 / 1 deg/step] |
Specifies the temperature of the heating roller for the overshoot prevention. |
|||
009 |
Overshoot Prevent Time |
*ENG |
[0 to 100 / 10 / 1 sec/step] |
Specifies the interval of the fusing unit rotation for the overshoot prevention. |
1122 |
[Standby Rotation Setting] DFU |
||
001 |
Rotation Interval |
*ENG |
[0 to 240 / 60 / 1 min/step] |
Specifies the rotation interval of the fusing unit in the stand-by mode. |
|||
002 |
Rotation Time |
*ENG |
[0 to 60 / 0.7 / 0.1 sec/step] |
Specifies the rotation time of the fusing unit in the stand-by mode. |
1124 |
[CPM Down Setting] |
||
Specifies the settings for the CPM down mode. |
|||
001 |
Low:Down Temp. |
*ENG |
[-50 to 0 / -20 / 1 deg/step] |
Specifies the CPM down threshold temperature for the low temperature condition. If the fusing temperature decreases -20°C (adjustable) below the target temperature, the machine enters the CPM down mode. |
|||
002 |
Low:Up Temp. |
*ENG |
[-50 to 0 / -15 / 1 deg/step] |
Specifies the CPM up threshold temperature for the low temperature condition. If the fusing temperature increases -15°C (adjustable) below the target temperature, the machine enters the CPM up mode. |
|||
003 |
Low :1st CPM |
*ENG |
[10 to 100 / 80 / 5 %/step] |
Specifies the 1st CPM down ration against the normal CPM in the low temperature condition. |
|||
004 |
Low :2nd CPM |
*ENG |
[10 to 100 / 65 / 5 %/step] |
Specifies the 2nd CPM down ration against the normal CPM in the low temperature condition. |
|||
005 |
Low :3rd CPM |
*ENG |
[10 to 100 / 50 / 5 %/step] |
Specifies the 3rd CPM down ration against the normal CPM in the low temperature condition. |
|||
006 |
High :1st CPM |
*ENG |
[10 to 100 / 75 / 5 %/step] |
Specifies the 1st CPM down ration against the normal CPM in the high temperature condition. |
|||
007 |
High:2nd CPM |
*ENG |
[10 to 100 / 50 / 5 %/step] |
Specifies the 3rd CPM down ration against the normal CPM in the high temperature condition. |
|||
008 |
High:3rd CPM |
*ENG |
[10 to 100 / 25 / 5 %/step] |
Specifies the 1st CPM down ration against the normal CPM in the high temperature condition. |
|||
009 |
High:1st CPM Down Temp.:A3 |
*ENG |
[100 to 250 / 230 / 1 deg/step] |
Specifies the heating roller temperature for 1st CPM down of A3 paper size. |
|||
010 |
High:2nd CPM Down Temp.:A3 |
*ENG |
[100 to 250 / 233 / 1 deg/step] |
Specifies the heating roller temperature for 2nd CPM down of A3 paper size. |
|||
011 |
High:3rd CPM Down Temp.:A3 |
*ENG |
[100 to 250 / 235 / 1 deg/step] |
Specifies the heating roller temperature for 3rd CPM down of A3 paper size. |
|||
012 |
High:1st CPM Down Temp.:A4 |
*ENG |
[100 to 250 / 180 / 1 deg/step] |
Specifies the heating roller temperature for 1st CPM down of A4 paper size. |
|||
013 |
High:2nd CPM Down Temp.:A4 |
*ENG |
[100 to 250 / 183 / 1 deg/step] |
Specifies the heating roller temperature for 2nd CPM down of A4 paper size. |
|||
014 |
High:3rd CPM Down Temp.:A4 |
*ENG |
[100 to 250 / 185 / 1 deg/step] |
Specifies the heating roller temperature for 3rd CPM down of A4 paper size. |
|||
015 |
High:1st CPM Down Temp.:B5:Press |
*ENG |
[100 to 250 / 175 / 1 deg/step] |
Specifies the pressure roller temperature for 1st CPM down of B5 paper size. |
|||
016 |
High:2nd CPM Down Temp.:B5:Press |
*ENG |
[100 to 250 / 180 / 1 deg/step] |
Specifies the pressure roller temperature for 2nd CPM down of B5 paper size. |
|||
017 |
High:3rd CPM Down Temp.:B5:Press |
*ENG |
[100 to 250 / 185 / 1 deg/step] |
Specifies the pressure roller temperature for 3rd CPM down of B5 paper size. |
|||
018 |
High:1st CPM Down Temp.:A5:Press |
*ENG |
[100 to 250 / 180 / 1 deg/step] |
Specifies the pressure roller temperature for 1st CPM down of A5 paper size. |
|||
019 |
High:2nd CPM Down Temp.:A5:Press |
*ENG |
[100 to 250 / 185 / 1 deg/step] |
Specifies the pressure roller temperature for 2nd CPM down of A5 paper size. |
|||
020 |
High:3rd CPM Down Temp.:A5:Press |
*ENG |
[100 to 250 / 190 / 1 deg/step] |
Specifies the pressure roller temperature for 3rd CPM down of A5 paper size. |
|||
021 |
High:1st CPM Down Temp.:A6:Press |
*ENG |
[100 to 250 / 160 / 1 deg/step] |
Specifies the pressure roller temperature for 1st CPM down of A6 paper size. |
|||
022 |
High:2nd CPM Down Temp.:A6:Press |
*ENG |
[100 to 250 / 165 / 1 deg/step] |
Specifies the pressure roller temperature for 2nd CPM down of A6 paper size. |
|||
023 |
High:3rd CPM Down Temp.:A6:Press |
*ENG |
[100 to 250 / 170 / 1 deg/step] |
Specifies the pressure roller temperature for 3rd CPM down of A6 paper size. |
|||
024 |
Judging Interval |
*ENG |
[0 to 250 / 5 / 1 sec/step] |
Specifies the interval for CPM down judgement. |
1131 |
[Continues Print Mode Switch] |
||
001 |
Feed Permit Condition |
*ENG |
[0 to 2 / 0 / 1 /step] 0: Productivity priority 1: Fusing quality priority 1 2: Fusing quality priority 2 |
Selects the paper feed permission type. |
1132 |
[Maximum Duty Switch] |
||
001 |
Control Method Switch |
*ENG |
[0 to 2 / 0 / 1 /step] 0: Fixed Duty, 1: Power Control |
1141 |
[Fusing SC Issue Time Info] |
||
001 |
SC Number |
*ENG |
Displays the issued SC number. |
002 |
SC Cause |
*ENG |
[0 to 9 / - / 1/step] |
101 |
Htg Roller:Ctr Diff1 |
*ENG |
[0 to 260 / - / 1 deg/step] Displays the temperature at the center of the heating roller when an SC was issued. |
102 |
Htg Rolloer:Ctr Det1 |
*ENG |
|
103 |
Htg Roller:Ctr Corr1 |
*ENG |
|
104 |
Htg Roller:End Diff1 |
*ENG |
[0 to 260 / - / 1 deg/step] Displays the temperature at the end of the heating roller when an SC was issued. |
105 |
Htg Roller:End Det1 |
*ENG |
|
106 |
Htg Roller:End Corr1 |
*ENG |
|
107 |
Press Roller Temp Value1 |
*ENG |
[0 to 260 / - / 1 deg/step] Displays the temperature at the pressure roller when an SC was issued. |
151 |
Htg Roller:Ctr Diff2 |
*ENG |
[0 to 260 / - / 1 deg/step] |
152 |
Htg Rolloer:Ctr Det2 |
*ENG |
|
153 |
Htg Roller:Ctr Corr2 |
*ENG |
|
154 |
Htg Roller:End Diff2 |
*ENG |
[0 to 260 / - / 1 deg/step] |
155 |
Htg Roller:End Det2 |
*ENG |
|
156 |
Htg Roller:End Corr2 |
*ENG |
|
157 |
Press Roller Temp Value2 |
*ENG |
[0 to 260 / - / 1 deg/step] |
201 |
Htg Roller:Ctr Diff3 |
*ENG |
[0 to 260 / - / 1 deg/step] |
202 |
Htg Rolloer:Ctr Det3 |
*ENG |
|
203 |
Htg Roller:Ctr Corr3 |
*ENG |
|
204 |
Htg Roller:End Diff3 |
*ENG |
[0 to 260 / - / 1 deg/step] |
205 |
Htg Roller:End Det3 |
*ENG |
|
206 |
Htg Roller:End Corr3 |
*ENG |
|
207 |
Press Roller Temp Value3 |
*ENG |
[0 to 260 / - / 1 deg/step] |
1142 |
[Fusing Jam Detection] |
||
001 |
SC Display |
*ENG |
[0 or 1 / 0 / -] |
Enables or disables the fusing consecutive jam (three times) SC detection. 0: No detection, 1: Detection |
1151 |
[Pressure Setting] |
||
001 |
Pressure Change ON/OFF |
*ENG |
[0 or 1 / 1 / -] |
Enables or disables the pressure switching control for the fusing unit. 0: OFF , 1: ON |
|||
002 |
Pressure Position1 |
*ENG |
[0 to 10,000 / 420 / 10 msec/step] |
Specifies the rotation time of the pressure roller contact motor for the pressure position 1. |
|||
003 |
Pressure Position2 |
*ENG |
[0 to 10,000 / 660 / 10 msec/step] |
Specifies the rotation time of the pressure roller contact motor for the pressure position 2. |
|||
004 |
Pressure Position3 |
*ENG |
[0 to 10,000 / 2130 / 10 msec/step] |
Specifies the rotation time of the pressure roller contact motor for the pressure position 3. |
|||
005 |
Depressure Position |
*ENG |
[0 to 10,000 / 220 / 10 msec/step] |
Specifies the rotation time of the pressure roller contact motor for the depression position (no pressure). |
|||
010 |
Shift Time |
*ENG |
[0 to 3600 / 5 / 1 sec/step] |
Specifies the timing for depressing the fusing unit. If the machine does not get any jobs for specified time by this SP after copying or printing, the machine depresses the fusing unit. |
|||
101 |
Pressure:Plain1/2 |
*ENG |
[0 to 3 / 3 / 1 /step] |
Sets the default pressure position of the fusing unit for each paper type in normal speed. 0: Depression position (no pressure) 1: Position 1 (less pressure) 2: Position 2 3: Position 3 (strongest pressure) |
|||
102 |
Pressure:Thin |
*ENG |
[0 to 3 / 3 / 1 /step] |
103 |
Pressure:M-thick |
*ENG |
[0 to 3 / 3 / 1 /step] |
104 |
Pressure:Thick1 |
*ENG |
[0 to 3 / 3 / 1 /step] |
105 |
Pressure:Thick2 |
*ENG |
[0 to 3 / 3 / 1 /step] |
106 |
Pressure:Thick3 |
*ENG |
[0 to 3 / 3 / 1 /step] |
107 |
Pressure:Special1 |
*ENG |
[0 to 3 / 3 / 1 /step] |
108 |
Pressure:Special2 |
*ENG |
[0 to 3 / 3 / 1 /step] |
109 |
Pressure:Special3 |
*ENG |
[0 to 3 / 3 / 1 /step] |
110 |
Pressure:Envelope |
*ENG |
[0 to 3 / 1 / 1 /step] |
151 |
Pressure:Plain1/2:Low Speed |
*ENG |
[0 to 3 / 3 / 1 /step] |
Sets the default pressure position of the fusing unit for each paper type in low speed. 0: Depression position (no pressure) 1: Position 1 (less pressure) 2: Position 2 3: Position 3 (strongest pressure) |
|||
152 |
Pressure:M-thick:Low Speed |
*ENG |
[0 to 3 / 3 / 1 /step] |
153 |
Pressure:Thick1:Low Speed |
*ENG |
[0 to 3 / 3 / 1 /step] |
154 |
Pressure:Special1:Low Speed |
*ENG |
[0 to 3 / 3 / 1 /step] |
155 |
Pressure:Special2:Low Speed |
*ENG |
[0 to 3 / 3 / 1 /step] |
156 |
Pressure:Plain1/2:Glossy |
*ENG |
[0 to 3 / 3 / 1 /step] |
157 |
Pressure:M-thick:Glossy |
*ENG |
[0 to 3 / 3 / 1 /step] |
158 |
Pressure:OHP |
*ENG |
[0 to 3 / 3 / 1 /step] |
159 |
Pressure:Envelope:Low Speed |
*ENG |
[0 to 3 / 1 / 1 /step] |
160 |
Pressure:Thin:Low Speed |
*ENG |
[0 to 3 / 3 / 1 /step] |
161 |
Pressure:Thick4 |
*ENG |
[0 to 3 / 3 / 1 /step] |
Sets the default pressure position of the fusing unit for thick 4 paper. 0: Depression position (no pressure) 1: Position 1 (less pressure) 2: Position 2 3: Position 3 (strongest pressure) |
|||
201 |
Filler Edge Detection Counter |
ENG |
[0 to 9,000,000 / - / 1 /step] |
Displays the detection time for the edge of the pressure roller actuator. |
1152 |
[Fusing Nip Band Check] |
||
001 |
Execute |
- |
[0 or 1 / 0 / 1] |
Executes the nip band measurement between heating roller and pressure roller. If the nip band width is not 8 mm, and fusing is not good, replace the pressure roller or install a new fusing unit. |
|||
002 |
Pre-Idling Time |
*ENG |
[0 to 255 / 240 / 1 sec/step] |
Specifies the fusing rotation time before executing SP1109-001. |
|||
003 |
Stop Time |
* ENG |
[5 to 30 / 20 / 1 sec/step] |
Specifies the time for measuring the nip. |
|||
004 |
Pressure Position |
* ENG |
[1 to 3 / 3 / 1 ] |
Specifies the pressure position for measuring the nip. |
1153 |
[Fuser Cleaning] |
||
001 |
Compulsion execution |
- |
Execute the fusing cleaning mode. |
002 |
Operation interval |
*ENG |
[1 to 300 / 0 / 1 K/step] |
Adjusts the execution interval for the fusing cleaning mode. 1K= 100 sheets |
|||
003 |
Control Temp. |
*ENG |
[0 to 200 / 180 / 1°C/step] |
Specifies the heating roller temperature for the fusing cleaning mode. |
|||
004 |
Page Count |
*ENG |
[1 to 300000 / - / 1 page/step] |
Displays the page counter for the fusing cleaning mode. |
1801 |
[Motor Speed Adj.] FA |
||
001 |
Registration:Plain:Low |
*ENG |
[–2 to 2 / –1.1 / 0.1 %/step] |
002 |
Registration:Plain:High |
*ENG |
[–2 to 2 / –0.1 / 0.1 %/step] |
003 |
Registration:Middle Thick:Low |
*ENG |
[–2 to 2 / –1.1 / 0.1 %/step] |
004 |
Registration:Middle Thick:Mid |
*ENG |
[–2 to 2 / –0.1 / 0.1 %/step] |
005 |
Registration:Middle Thick:High |
*ENG |
|
006 |
Registration:Thick 1:Low |
*ENG |
[–2 to 2 / –1.1 / 0.1 %/step] |
007 |
Registration:Thick1:Mid |
*ENG |
[–2 to 2 / –0.1 / 0.1 %/step] |
008 |
Registration:Thick 2:Low |
*ENG |
[–2 to 2 / –1.1 / 0.1 %/step] |
009 |
Registration:Thick 3:Low |
*ENG |
|
010 |
Duplex CW:Plane:Low |
*ENG |
[–4 to 4 / 0.0 / 0.1 %/step] |
011 |
Duplex CW:Normal:High |
*ENG |
|
012 |
Duplex CW:Middle Thick:Low |
*ENG |
|
013 |
Duplex CW:Middle Thick:Mid |
*ENG |
|
014 |
Duplex CW:Middle Thick:High |
*ENG |
|
015 |
Duplex CW:Thick1:Low |
*ENG |
|
016 |
Duplex CW:Thick1:Mid |
*ENG |
|
017 |
Duplex CW:Thick2:Low |
*ENG |
|
018 |
Duplex CW:Thick3:Low |
*ENG |
|
019 |
Duplex CCW:Normal:High |
*ENG |
[–4 to 4 / 0.0 / 0.1 %/step] |
020 |
Duplex CCW:Middle Thick:Mid |
*ENG |
|
021 |
Duplex CCW:Middle Thick:high |
*ENG |
|
023 |
Duplex CCW:Thick1:Mid |
*ENG |
|
024 |
Reverse CW:Normal:High |
*ENG |
[–4 to 4 / –0.5 / 0.1%/step] |
025 |
Reverse CW:Middle Thick:Mid |
*ENG |
[–4 to 4 / 0 / 0.1 %/step] |
026 |
Reverse CW:Middle Thick:High |
*ENG |
[–4 to 4 / –0.5 / 0.1%/step] |
028 |
Reverse CW:Thick1:Mid |
*ENG |
[–4 to 4 / 0 / 0.1 %/step] |
029 |
Reverse CCW:Normal:High |
*ENG |
|
030 |
Reverse CCW:Middle Thick:Mid |
*ENG |
|
031 |
Reverse CCW:Middle Thick:High |
*ENG |
|
033 |
Reverse CCW:Thick1:Mid |
*ENG |
|
034 |
Feed:Plain:Low |
*ENG |
[–2 to 2 / –1.1 / 0.1 %/step] |
035 |
Feed:Plain:High |
*ENG |
[–2 to 2 / –0.1 / 0.1 %/step] |
036 |
Feed:Middle thick:Low |
*ENG |
[–2 to 2 / –1.1 / 0.1 %/step] |
037 |
Feed:Middle thick:Mid |
*ENG |
[–2 to 2 / –0.1 / 0.1 %/step] |
038 |
Feed:Middle thick:High |
*ENG |
|
039 |
Feed:Thick 1:Low |
*ENG |
[–2 to 2 / –1.1 / 0.1 %/step] |
040 |
Feed:Thick 1:Mid |
*ENG |
[–2 to 2 / –0.1 / 0.1 %/step] |
041 |
Feed:Thick 2:Low |
*ENG |
[–2 to 2 / –1.1 / 0.1 %/step] |
042 |
Feed:Thick 3:Low |
*ENG |
|
043 |
Bridge Motor:Low |
*ENG |
[–4 to 4 / 0 / 0.1 %/step] |
044 |
Bridge Motor:Mid |
*ENG |
|
045 |
Bridge Motor:High |
*ENG |
|
060 |
KOpcDevMot:High |
*ENG |
[–4 to 4 / –0.6 / 0.01 %/step] |
061 |
KOpcDevMot:Mid |
*ENG |
|
062 |
KOpcDevMot:Low |
*ENG |
|
063 |
MOpcDevMot:High |
*ENG |
[–10 to 10 / 0 / 1 step/step] |
064 |
MOpcDevMot:Mid |
*ENG |
[–9 to 9 / 0 / 1 step/step] |
065 |
MOpcDevMot:Low |
*ENG |
[–14 to 14 / 0 / 1 step/step] |
066 |
COpcDevMot:High |
*ENG |
[–10 to 10 / 0 / 1 step/step] |
067 |
COpcDevMot:Mid |
*ENG |
[–9 to 9 / 0 / 1 step/step] |
068 |
COpcDevMot:Low |
*ENG |
[–14 to 14 / 0 / 1 step/step] |
069 |
YOpcDevMot:High |
*ENG |
[–10 to 10 / 0 / 1 step/step] |
070 |
YOpcDevMot:Mid |
*ENG |
[–9 to 9 / 0 / 1 step/step] |
071 |
YOpcDevMot:Low |
*ENG |
[–14 to 14 / 0 / 1 step/step] |
072 |
Fusing: High |
*ENG |
[–4 to 4 / 1.9 / 0.01 %/step] |
073 |
Fusing: Mid |
*ENG |
[–4 to 4 / 1.4 / 0.01 %/step] |
074 |
Fusing: Low |
*ENG |
[–4 to 4 / 1.7 / 0.01 %/step] |
075 |
TransferMot:High |
*ENG |
[–4 to 4 / –0.2 / 0.01 %/step] |
076 |
TransferMot:Mid |
*ENG |
|
077 |
TransferMot:Low |
*ENG |
|
078 |
TonerMot |
*ENG |
[–30 to 30 / 10 / 5 %/step] |
079 |
Fusing Exit Motor: 1200 |
*ENG |
[–4 to 4 / 2.1 / 0.01 %/step] |
100 |
Drum Adjust |
*ENG |
[0 or 1 / 1 / 1] 0: Off, 1: On |
Enables or disables the drum amplitude adjustment. |
|||
101 |
MOpcDevMot:High |
*ENG |
[–7 to 7 / 0 / 1 step/step] |
102 |
COpcDevMot:High |
*ENG |
|
103 |
YOpcDevMot:High |
*ENG |
|
104 |
MOpcDevMot:Mid |
*ENG |
[–7 to 7 / 0 / 1 step/step] |
105 |
COpcDevMot:Mid |
*ENG |
|
106 |
YOpcDevMot:Mid |
*ENG |
|
107 |
MOpcDevMot:Low |
*ENG |
[–14 to 14 / 0 / 1 step/step] |
108 |
COpcDevMot:Low |
*ENG |
|
109 |
YOpcDevMot:Low |
*ENG |
|
110 |
MOpcDevMot:1200 |
*ENG |
[– 7 to 7 / 0 / 1 step/step] |
111 |
COpcDevMot:1200 |
*ENG |
|
112 |
YOpcDevMot:1200 |
*ENG |
|
120 |
Long:Registration:Plain:High |
*ENG |
[–2 to 2 / -0.1 / 0.1 %/step] |
121 |
Long:Registration:Plain:Low |
*ENG |
[–2 to 2 / -1.1 / 0.1 %/step] |
122 |
Long:Registration:Middle Thick:High |
*ENG |
[–2 to 2 / -0.1 / 0.1 %/step] |
123 |
Long:Registration:Middle Thick:Middle |
*ENG |
|
124 |
Long:Registration:Middle Thick:Low |
*ENG |
[–2 to 2 / -1.1 / 0.1 %/step] |
125 |
Long:Registration:Thick 1:Middle |
*ENG |
[–2 to 2 / -1 / 0.1 %/step] |
126 |
Long:Registration:Thick 1:Low |
*ENG |
[–2 to 2 / -1.1 / 0.1 %/step] |
127 |
Long:Registration:Thick 2:Low |
*ENG |
[–2 to 2 / -1.1 / 0.1 %/step] |
128 |
Long:Registration:Thick 3:Low |
*ENG |
[–2 to 2 / -1.1 / 0.1 %/step] |
129 |
Long:Fusing:Plain:High |
*ENG |
[–4 to 4 / 1.9 / 0.01 %/step] |
130 |
Long:Fusing:Plain:Low |
*ENG |
[–4 to 4 / 2.1 / 0.01 %/step] |
131 |
Long:Fusing:Middle Thick:High |
*ENG |
[–4 to 4 / 1.9 / 0.01 %/step] |
132 |
Long:Fusing:Middle Thick:Middle |
*ENG |
[–4 to 4 / 1.4 / 0.01 %/step] |
133 |
Long:Fusing:Middle Thick:Low |
*ENG |
[–4 to 4 / 2.1 / 0.01 %/step] |
134 |
Long:Fusing:Thick 1:Middle |
*ENG |
[–4 to 4 / 2.0 / 0.01 %/step] |
135 |
Long:Fusing:Thick 1:Low |
*ENG |
[–4 to 4 / 1.7 / 0.01 %/step] |
136 |
Long:Fusing:Thick 2:Low |
*ENG |
[–4 to 4 / 1.7 / 0.01 %/step] |
137 |
Long:Fusing:Thick 3:Low |
*ENG |
[–4 to 4 / 1.7 / 0.01 %/step] |
1902 |
[Amplitude Control] |
||
001 |
Execute |
- |
Execute drum phase adjustment. |
002 |
Result |
*ENG |
[0 to 3 / 0 / 1] Displays the result of drum phase adjustment. 0: Successfully done 2: Sampling failure 3: Insufficient detection number |
003 |
Auto Execution |
*ENG |
[0 or 1 / 1 / -] Turns the automatic drum phase adjustment on or off. 0: Off, 1: On |
1907 |
[Paper Feed Timing Adj.] DFU |
||
002 |
Feed Solenoid ON: Plain |
*ENG |
[35 to 85 / 60 / 5 %/step] |
003 |
Feed Clutch OFF: Plain |
*ENG |
[–10 to 10 / 0 / 1 mm/step] |
004 |
Feed Clutch ON: Plain |
*ENG |
|
005 |
Inverter Stop Position |
*ENG |
|
006 |
Reverse Stop Position |
*ENG |
|
007 |
Re-Feed Stop Position S Size |
*ENG |
|
008 |
By-pass Solenoid OFF |
*ENG |
[0 to 40 / 0 / 1 mm/step] |
009 |
By-pass Solenoid Re-ON |
*ENG |
[0 or 1 / 1 / -] |
010 |
By-pass Feed Clutch ON |
*ENG |
[–10 to 10 / 0 / 1 mm/step] |
012 |
Feed Solenoid ON: Thick |
*ENG |
[–10 to 40 / 0 / 2.5 mm/step] |
013 |
Feed Clutch OFF: Thick |
*ENG |
[–10 to 10 / 0 / 1 mm/step] |
014 |
Feed Clutch ON: Thick |
*ENG |
|
015 |
Re-Feed Stop Position |
*ENG |
1908 |
[LCT Feed Timing Adj.] DFU |
||
010 |
Bridge Junction Gate Sol-ON |
*ENG |
[–10 to 10 / 0 / 1 mm/step] |
011 |
Bridge Junction Gate Sol-OFF |
*ENG |
|
012 |
1 Bin Junction Gate Sol-ON |
*ENG |
|
013 |
1 Bin Junction Gate Sol-OFF |
*ENG |
|
015 |
Junction Gate SOL1:ON:Plain |
*ENG |
|
016 |
Junction Gate SOL1:ON:Thick |
*ENG |
|
017 |
Junction Gate SOL1:OFF:Plain |
*ENG |
|
018 |
Junction Gate SOL1:OFF:Thick |
*ENG |
1950 |
[Fan Cooling Time Set] |
||
Adjust the rotation time for each fan motor after a job end. |
|||
002 |
Fusing Exit Fan |
*ENG |
[0 to 120 / 0 / 0.1 min./step] |
006 |
Main Suction Fan |
*ENG |
|
007 |
Paper Exit Fan |
*ENG |
|
008 |
PSU Fan |
*ENG |
|
009 |
Fusing IH Coil Fan |
*ENG |
|
010 |
IH Power Supply Fan |
*ENG |
|
011 |
Second Duct Fan |
*ENG |
|
012 |
Third Duct Fan |
*ENG |
1951 |
[Fan Start Time Set] |
||
Adjust the start time for each fan motor after a job end. |
|||
002 |
Fusing Exit Fan |
*ENG |
[0 to 900 / 0 / 1 sec/step] |
006 |
Main Suction Fan |
*ENG |
[0 to 900 / 120 / 1 sec/step] |
007 |
Paper Exit Fan |
*ENG |
[0 to 900 / 0 / 1 sec/step] |
008 |
PSU Fan |
*ENG |
[0 to 900 / 120 / 1 sec/step] |
009 |
Fusing IH Coil Fan |
*ENG |
[0 to 900 / 0 / 1 sec/step] |
010 |
IH Power Supply Fan |
*ENG |
|
011 |
Second Duct Fan |
*ENG |
|
012 |
Third Duct Fan |
*ENG |
1952 |
[Fan Control Off Mode Time Set] |
||
001 |
- |
*ENG |
[0 to 60 / 10 / 1 min./step] |
1953 |
[Extra Fan Control] |
||
001 |
Extra Fan Cooling State |
*ENG |
[0 or 1 / 0 / 1 /step] 0: Off, 1: On |
Displays the extra fan cooling is On or Off. |
|||
002 |
Extra Fan Cooling: Time: Threshold |
*ENG |
[0 to 180 / C2.5a: 110, C2.5b: 100 / 1 min./step] |
Specifies the judgement time for entering the extra fan rotation mode. |
|||
003 |
Extra Fan Cooling: Rotat: Threshold |
*ENG |
[0 to 999999999 / 0 / 1 mm/step] |
Specifies the threshold rotation of the black development unit for entering the extra fan rotation mode. |
|||
004 |
Extra Fan Cooling: Start Date |
*ENG |
Displays the execution time and date of the extra fan cooling. |
005 |
Extra Fan Cooling Time |
*ENG |
[0 to 120 / 30 / 0.1 min./step: |
Specifies the execution time for the extra fan cooling. |
1954 |
[Extra Fan Control] |
||
Specifies the execution time of the extra fan rotaion mode for each fan motor. |
|||
002 |
Fan Cooling Time:Fusing Exit Fan:Initial |
*ENG |
[0 to 120 / 0 / 0.1 min./step] |
006 |
Fan Cooling Time:Main Suction Fan:Initial |
*ENG |
[0 to 120 / 0 / 0.1 min./step] |
007 |
Fan Cooling Time:Paper Exit Fan:Initial |
*ENG |
[0 to 120 / 0 / 0.1 min./step] |
008 |
Fan Cooling Time:PSU Fan:Initial |
*ENG |
[0 to 120 / 0 / 0.1 min./step] |
009 |
Fan Cooling Time:Fusing IH Coil Fan:Initial |
*ENG |
[0 to 120 / 0 / 0.1 min./step] |
010 |
Fan Cooling Time:IH Power Supply Fan:Initial |
*ENG |
[0 to 120 / 0 / 0.1 min./step] |
011 |
Fan Cooling Time:Second Duct Fan:Initial |
*ENG |
[0 to 120 / 0 / 0.1 min./step] |
012 |
Fan Cooling Time:Third Duct Fan:Initial |
*ENG |
[0 to 120 / 0 / 0.1 min./step] |