SP7-XXX (Data Log)

7401

[Total SC Counter]

Displays the number of SC codes detected.

001

SC Counter

*CTL

[0 to 9999 / 0 / 1/step ]

7403

[SC History]

Logs the SC codes detected.

The 10 most recently detected SC Codes are not displayed on the screen, but can be seen on the SMC (logging) outputs.

001

Latest

*CTL

-

002

Latest 1

003

Latest 2

004

Latest 3

005

Latest 4

006

Latest 5

007

Latest 6

008

Latest 7

009

Latest 8

010

Latest 9

7404

[SC991 History]

Logs the SC991 detected.

The 10 most recently detected SC991 are not displayed on the screen, but can be seen on the SMC (logging) outputs.

001

Latest

*CTL

-

002

Latest 1

003

Latest 2

004

Latest 3

005

Latest 4

006

Latest 5

007

Latest 6

008

Latest 7

009

Latest 8

010

Latest 9

7502

[Total Paper Jam Counter]

Displays the total number of jams detected.

001

Total Jam

* CTL

[0 to 9999 / 0 / 1 sheet/step ]

7503

[Total Original Jam Counter]

Displays the total number of original jams.

001

Original Jam counter

*CTL

[0 to 9999 / 0 / 1 original/step ]

7504

[Paper Jam Location]

ON: On check, OFF: Off Check

Displays the number of jams according to the location where jams were detected.

NOTE: The LCT is counted as the 3rd feed station.

001

At Power On

*CTL

For details, (_point.png"Jam Detection" in the "Main Chapters: Jam Detection" section.)

003

Tray 1: ON

*CTL

004

Tray 2: ON

*CTL

005

Tray 3: ON

*CTL

006

Tray 4: ON

*CTL

007

LCT : ON

*CTL

008

Bypass: ON

*CTL

009

Duplex: ON

*CTL

011

Vertical Transport 1: ON

*CTL

012

Vertical Transport 2: ON

*CTL

013

Bank: Transport Sn1

*CTL

For details, (_point.png "Jam Detection" in the "Main Chapters: Jam Detection" section.)

014

Bank: Transport Sn2

*CTL

017

Registration: ON

*CTL

018

Fusing Entrance: ON

*CTL

019

Fusing Exit: ON

*CTL

020

Paper Exit: ON

*CTL

021

Bridge Exit: ON

*CTL

022

Bridge Transport: ON

*CTL

024

Junction Gate Sensor : On

*CTL

025

Duplex Exit: ON

*CTL

For details, (_point.png "Jam Detection" in the "Main Chapters: Jam Detection" section.)

026

Duplex Entrance: ON (Out)

*CTL

027

Duplex Entrance: ON (Out)

*CTL

051

Vertical Transport 1: Off

*CTL

052

Vertical Transport 2: Off

*CTL

053

Bank Transport 1: Off

*CTL

054

Bank Transport 2: Off

*CTL

057

Registration Sensor: Off

*CTL

058

LCT Feed Sensor : Off

*CTL

060

Paper Exit Off

*CTL

061

Bridge Exit: Off

*CTL

062

Bridge Transport: Off

*CTL

064

Junction Gate Sensor : Off

*CTL

For details, (_point.png "Jam Detection" in the "Main Chapters: Jam Detection" section.)

065

Duplex Exit: Off

*CTL

066

Duplex Entrance: Off (In)

*CTL

067

Duplex entrance : Off (Out)

*CTL

100

Finisher Entrance: KIN

*CTL

101

Finisher Shift Tray Exit: KIN

*CTL

102

Finisher Staple: KIN

*CTL

103

Finisher Exit: KIN

*CTL

105

Finisher Tray Lift Motor: KIN

*CTL

106

Finisher Jogger Motor: KIN

*CTL

107

Finisher Shift Motor: KIN

*CTL

108

Finisher Staple Motor: KIN

*CTL

109

Finisher Exit Motor: KIN

*CTL

For details, (_point.png "Jam Detection" in the "Main Chapters: Jam Detection" section.)

191

Finisher Entrance: EUP

*CTL

192

Finisher Proof Exit: EUP

*CTL

193

Finisher Shift Tray Exit: EUP

*CTL

194

Finisher Stapler Exit: EUP

*CTL

195

Finisher Exit: EUP

*CTL

198

Finisher Folder: EUP

*CTL

199

Finisher Tray Motor: EUP

*CTL

200

Finisher Jogger Motor: EUP

*CTL

For details, (_point.png "Jam Detection" in the "Main Chapters: Jam Detection" section.)

201

Finisher Shift Motor: EUP

*CTL

202

Finisher Staple Moving Motor: EUP

*CTL

203

Finisher Staple Motor: EUP

*CTL

204

Finisher Folder Motor: EUP

*CTL

206

Finisher Punch Motor: EUP

*CTL

230

Fin Exit

*CTL

231

Insufficient Data

*CTL

7505

[Original Jam Detection]

Displays the total number of original jams by location.

001

At Power On

*CTL


003

Separation Sensor: On

*CTL


004

Skew Correction Sensor: On

*CTL


005

Scanning Entrance Sensor: On

*CTL


006

Registration Sensor: On

*CTL

Not used

007

Original Exit Sensor: On

*CTL

008

Reverse Sensor: On

*CTL

013

Separation Sensor: On

*CTL

014

Skew Correction Sn: On

*CTL

015

Scanning Entrance Sn: On

*CTL

016

Registration Sensor: On

*CTL

017

Original Exit Sensor: On

*CTL

053

Separation Sensor: Off

*CTL


054

Skew Correction Sensor: Off

*CTL


055

Scanning Entrance Sensor: Off

*CTL


056

Registration Sensor: Off

*CTL

Not used

057

Original Exit Sensor: Off

*CTL

058

Reverse Sensor: Off

*CTL

063

Separation Sensor: Off

*CTL

064

Skew Correction Sn: Off

*CTL

065

Scanning Entrance Sn: Off

*CTL

066

Registration Sensor: Off

*CTL

067

Original Exit Sensor: Off

*CTL

7506

[Jam Count by Paper Size]

Displays the number of jams according to the paper size.

005

A4 LEF

*CTL

[0 to 9999 / 0 / 1 sheet/step ]

006

A5 LEF

014

B5 LEF

038

LT LEF

044

HLT LEF

132

A3 SEF

133

A4 SEF

134

A5 SEF

141

B4 SEF

142

B5 SEF

160

DLT SEF

164

LG SEF

166

LT SEF

172

HLT SEF

255

Others

7507

[Plotter Jam History]

Displays the 10 most recently detected paper jams.

001

Latest

*CTL

-

002

Latest 1

003

Latest 2

004

Latest 3

005

Latest 4

006

Latest 5

007

Latest 6

008

Latest 7

009

Latest 8

010

Latest 9

7508

[Original Jam History]

Displays the 10 most recently detected original jams.

001

Latest

*CTL

-

002

Latest-1

003

Latest-2

004

Latest-3

005

Latest-4

006

Latest-5

007

Latest-6

008

Latest-7

009

Latest-8

010

Latest-9

7624

Part Replacement Operation ON/OFF

Selects the PM maintenance for each part.

001

Drum Unit: Bk

[0 or 1 / 1 -]

0: No (Not PM maintenance)

1: Yes (PM maintenance)

002

Drum Unit: M

003

Drum Unit: C

004

Drum Unit: Y

005

Development Unit: Bk

006

Development Unit: M

007

Development Unit: C

008

Development Unit: Y

009

Developer: Bk

010

Developer: M

011

Developer: C

012

Developer: Y

013

Image Transfer Belt

[0 or 1 / 1 -]

0: Not PM maintenance

1: PM maintenance

014

Image Transfer Cleaning Unit

015

Fusing Unit

016

Paper Transfer Roller Unit

017

Waste Toner Bottle

018

Fusing Roller

019

Pressure Roller

7801

[ROM No/ Firmware Version]

255

Engine

*CTL

Displays all versions and ROM numbers in the machine.

7803

[PM Counter Display]

(Page, Unit, [Color])


Displays the number of sheets printed for each current maintenance unit.

PM counters click up based on the number of A4 (LT) LEF size sheets printed. Therefore, the A3 (DLT) Double Count is activated. The Double Count cannot be deactivated.

When a unit is replaced, the machine automatically detects that the new unit is installed. Then, the current PM counter value is automatically moved to the PM Counter - Previous (SP7-906-1 to 10) and is reset to “0”.

The total number of sheets printed with the last unit replaced can be checked with SP7-906-1 to 10.

NOTE: The LCT is counted as the 3rd feed station.

001

Paper

*CTL

[0 to 9999999 / - / 1 sheet/ step]

002

Page: PCU: Bk

*ENG

[0 to 9999999 / - / 1 sheet/ step]

003

Page: PCU: M

*ENG

004

Page: PCU: C

*ENG

005

Page: PCU: Y

*ENG

006

Page: Development Unit: Bk

*ENG

007

Page: Development Unit: M

*ENG

008

Page: Development Unit: C

*ENG

009

Page: Development Unit: Y

*ENG

010

Page: Developer: Bk

*ENG

011

Page: Developer: M

*ENG

012

Page: Developer: C

*ENG

013

Page: Developer: Y

*ENG

014

Page: Image Transfer

*ENG

[0 to 9999999 / - / 1 sheet/ step]

015

Page: Cleaning Unit

*ENG

016

Page: Fusing Unit

*ENG

017

Page: Paper Transfer Unit

*ENG

018

Page: Toner Collection Bottle

*ENG

019

Page: Fusing Roller

*ENG

020

Page: Pressure Roller

*ENG


Displays the number of revolutions of motors or clutches for each current maintenance unit.

[ 0 to 9999999 / 0 / 1 revolution/step ]

When a unit is replaced, the machine automatically detects that the new unit is installed. Then, the current PM counter value is automatically moved to the PM Counter - Previous (SP7-906-11 to 20) and is reset to “0”. The total number of revolutions made with the last unit replaced can be checked with SP7-906-11 to 20.

031

Rotation: PCU: Bk

*ENG

[0 to 999999999 / - / 1 mm/step ]

032

Rotation: PCU: M

033

Rotation: PCU: C

034

Rotation: PCU: Y

035

Rotation: Development Unit: Bk

036

Rotation: Development Unit: M

037

Rotation: Development Unit: C

038

Rotation: Development Unit: Y

039

Rotation: Developer Bk

040

Rotation: Developer M

041

Rotation: Developer C

042

Rotation: Developer Y

043

Rotation: Image Transfer

*ENG

[0 to 999999999 / - / 1 mm/step ]

044

Rotation: Cleaning Unit

045

Rotation: Fusing Unit

046

Rotation: Paper Transfer Unit

047

Measurement: Toner Collection bottle

*ENG

[0 to 999999999 / - / 1 mg/step ]

048

Rotation: Fusing Roller

*ENG

[0 to 999999999 / - / 1 mm/step ]

049

Rotation: Pressure Roller


Displays the value given by the following formula:

(Current revolution Target revolution) 100. This shows how much of the unit’s expected lifetime has been used up.

The Rotation% counter is based on rotations, not prints. If the number of rotations reaches the limit, the machine enters the end condition for that unit. If the print count lifetime is reached first, the machine also enters the end condition, even though the R% counter is still less than 100%.

061

Rotation (%): PCU: Bk

*ENG

[0 to 255 / - / 1 %/step]

062

Rotation (%): PCU: M

063

Rotation (%): PCU: C

064

Rotation (%): PCU: Y

065

Rotation (%): Development Unit: Bk

066

Rotation (%): Development Unit: M

067

Rotation (%): Development Unit: C

068

Rotation (%): Development Unit: Y

069

Rotation (%): Developer Bk

070

Rotation (%): Developer M

071

Rotation (%): Developer C

072

Rotation (%): Developer Y

073

Rotation (%): Image Transfer Belt

*ENG

[0 to 255 / - / 1 %/step]

074

Rotation (%): Cleaning Unit

075

Rotation (%): Fusing Unit

076

Rotation (%): Paper Transfer Unit

077

Measurement (%): Toner Collection bottle

078

Rotation (%): Fusing Roller

079

Rotation (%): Pressure Roller


Displays the value given by the following formula:

(Current printouts Target printouts) 100. This shows how much of the unit’s expected lifetime has been used up.

The Page% counter is based on printouts, not revolutions. If the number of printouts reaches the limit, the machine enters the end condition for that unit. If the revolution count lifetime is reached first, the machine also enters the end condition, even though the Page% counter is still less than 100%.

091

Page (%): PCU Bk (Drum Unit)

*ENG

[0 to 255 / - / 1 %/step]

092

Page (%): PCU M (Drum Unit)

093

Page (%): PCU C (Drum Unit)

094

Page (%): PCU Y (Drum Unit)

095

Page (%): Development Unit: Bk

096

Page (%): Development Unit: M

097

Page (%): Development Unit: C

098

Page (%): Development Unit: Y

099

Page (%): Developer: Bk

*ENG

[0 to 255 / - / 1 %/step]

100

Page (%): Developer: M

101

Page (%): Developer: C

102

Page (%): Developer: Y

103

Page (%): Image Transfer

104

Page (%): Cleaning Unit

105

Page (%): Fusing Unit

106

Page (%): Paper Transfer Unit

107

Page (%): Fusing Roller

108

Page (%): Pressure Roller

7804

[PM Counter Reset] PM Counter Clear

(Unit, [Color])


Clears the PM counter.

Press the Enter key after the machine asks “Execute?”, which will store the PM counter value in SP7-906 (PM Counter - Previous) and reset the value of the current PM counter (SP7-803) to “0”.

002

PCU (Drum Unit): Bk

-

-

003

PCU (Drum Unit): M

004

PCU (Drum Unit): C

005

PCU (Drum Unit): Y

006

PCU (Drum Unit): All

007

Development Unit: Bk

008

Development Unit: M

009

Development Unit: C

010

Development Unit: Y

011

Development Unit: All

012

Developer: Bk

-

-

013

Developer: M

014

Developer: C

015

Developer: Y

016

Developer: All

017

Image Transfer Belt

018

Cleaning Unit

019

Fusing Unit

020

Paper Transfer Unit

021

Toner Collection Bottle

022

Fusing Roller

023

Pressure Roller

100

All

7807

[SC/Jam Counter Reset]

Clears the counters related to SC codes and paper jams.

001

SC/Jam Clear

-

-

7826

[MF Error Counter] Japan Only

001

Error Total

002

Error Staple

7827

[MF Error Counter Clear] Japan Only

7832

[Self-Diagnose Result Display]

Displays the result of the diagnostics.

001

Diag. Result

*CTL

-

7835

[ACC Counter]

001

Copy ACC

*CTL

Displays the ACC exectuion times for each mode.

002

Printer ACC

*CTL

7836

Total Memory Size

Displays the memory capacity of the controller system.

7852

[DF Scan Glass Dust Check Counter]

Counts the number of occurrences (0 to 65,535) when dust was detected on the scanning glass of the ADF or resets the dust detection counter. Counting is done only if SP4-020-1 (ADF Scan Glass Dust Check) is switched on.

001

Dust Detection Counter

*CTL

[0 to 9999 / - / 1 /step]

002

Dust Detection Clear Counter

*CTL

[0 to 9999 / - / 1 /step]

003

Dust Detection Counter: Back

*CTL

[0 to 9999 / - / 1 /step]

7853

[Replacement Counter]

Displays the PM parts replacement number.

001

PCU: Bk

*CTL

[0 to 255 / - / 1 /step]

002

PCU: M

*CTL

003

PCU: C

*CTL

004

PCU: Y

*CTL

005

Development Unit: Bk

*CTL

006

Development Unit: M

*CTL

007

Development Unit: C

*CTL

008

Development Unit: Y

*CTL

009

Developer: Bk

*CTL

010

Developer: M

*CTL

011

Developer: C

*CTL

012

Developer: Y

*CTL

013

Image Transfer

*CTL

[0 to 255 / - / 1 /step]

014

Cleaning Unit

*CTL

015

Fusing Unit

*CTL

016

Paper Transfer Unit

*CTL

017

Toner Collection Bottle

*CTL

018

Fusing Roller

*CTL

019

Pressure Roller

*CTL

7855

[Coverage Range]

Sets the color coverage threshold.

Coverage rate = Coverage per page / A4 full coverage (dots) x 100

There are three coverage counters: Color 1, Color 2, and Color 3

  • [A] 5% (default) is adjustable with SP7855-001.

  • [B] 20% (default) is adjustable with SP7855-002.

g190tcoverage.png

Note

  • The setting value [B] must be set larger than [A].

The total numbers of printouts (BW printing plus color printing) for each coverage range are displayed with the following SPs.

  • Color1 counter: SP8601-021

  • Color2 counter: SP8601-022

  • Color3 counter: SP8601-023

001

Coverage Range 1

*CTL

[1 to 200 / 5 /1]

002

Coverage Range 2

*CTL

[1 to 200 / 20 /1]

7901

[Assert Info] DFU

Records the location where a problem is detected in the program. The data stored in this SP is used for problem analysis.

001

File Name

*CTL

-

002

Number of Lines

003

Location

7906

[Prev. Unit PM Counter]

(Page or Rotations, Unit, [Color]), Dev.: Development Unit

Displays the number of sheets printed with the previous maintenance units.

001

Paper

*CTL

[0 to 9999999 / - / 1 sheet/ step]

002

Page: PCU: Bk

*ENG

[0 to 9999999 / - / 1 sheet/ step]

003

Page: PCU: M

*ENG

004

Page: PCU: C

*ENG

005

Page: PCU: Y

*ENG

006

Page: Development Unit: Bk

*ENG

007

Page: Development Unit: M

*ENG

008

Page: Development Unit: C

*ENG

009

Page: Development Unit: Y

*ENG

010

Page: Developer: Bk

*ENG

011

Page: Developer: M

*ENG

012

Page: Developer: C

*ENG

013

Page: Developer: Y

*ENG

014

Page: Image Transfer

*ENG

[0 to 9999999 / - / 1 sheet/ step]

015

Page: Cleaning Unit

*ENG

016

Page: Fusing Unit

*ENG

017

Page: Paper Transfer Unit

*ENG

018

Page: Toner Collection Bottle

*ENG

019

Page: Fusing Roller

*ENG

020

Page: Pressure Roller

*ENG


Displays the number of revolutions for motors or clutches in the previous maintenance units.

031

Rotation: PCU: Bk

*ENG

[0 to 999999999 / - / 1 mm/step ]

032

Rotation: PCU: M

033

Rotation: PCU: C

034

Rotation: PCU: Y

035

Rotation: Development Unit: Bk

036

Rotation: Development Unit: M

037

Rotation: Development Unit: C

038

Rotation: Development Unit: Y

039

Rotation: Developer Bk

040

Rotation: Developer M

041

Rotation: Developer C

042

Rotation: Developer Y

043

Rotation: Image Transfer

*ENG

[0 to 999999999 / - / 1 mm/step ]

044

Rotation: Cleaning Unit

045

Rotation: Fusing Unit

046

Rotation: Paper Transfer Unit

047

Measurement: Toner Collection bottle

*ENG

[0 to 999999999 / - / 1 mg/step ]

048

Rotation: Fusing Roller

*ENG

[0 to 999999999 / - / 1 mm/step ]

049

Rotation: Pressure Roller


Displays the number of sheets printed with the previous maintenance unit or toner cartridge.

061

Rotation (%): PCU: Bk

*ENG

[0 to 255 / - / 1 %/step]

062

Rotation (%): PCU: M

063

Rotation (%): PCU: C

064

Rotation (%): PCU: Y

065

Rotation (%): Development Unit: Bk

066

Rotation (%): Development Unit: M

067

Rotation (%): Development Unit: C

068

Rotation (%): Development Unit: Y

069

Rotation (%): Developer Bk

070

Rotation (%): Developer M

071

Rotation (%): Developer C

072

Rotation (%): Developer Y

073

Rotation (%): Image Transfer Belt

*ENG

[0 to 255 / - / 1 %/step]

074

Rotation (%): Cleaning Unit

075

Rotation (%): Fusing Unit

076

Rotation (%): Paper Transfer Unit

077

Measurement (%): Toner Collection bottle

078

Rotation (%): Fusing Roller

079

Rotation (%): Pressure Roller


Displays the value given by the following formula:

(Current count Yield count) x 100, where “Current count” is the current values in the counter for the part, and “Yield count” is the recommended yield.

091

Page (%): PCU Bk (Drum Unit)

*ENG

[0 to 255 / - / 1 %/step]

092

Page (%): PCU M (Drum Unit)

093

Page (%): PCU C (Drum Unit)

094

Page (%): PCU Y (Drum Unit)

095

Page (%): Development Unit: Bk

096

Page (%): Development Unit: M

097

Page (%): Development Unit: C

098

Page (%): Development Unit: Y

099

Page (%): Developer: Bk

*ENG

[0 to 255 / - / 1 %/step]

100

Page (%): Developer: M

101

Page (%): Developer: C

102

Page (%): Developer: Y

103

Page (%): Image Transfer

104

Page (%): Cleaning Unit

105

Page (%): Fusing Unit

106

Page (%): Paper Transfer Unit

107

Page (%): Fusing Roller

108

Page (%): Pressure Roller

7931

[Toner Bottle Bk]

Displays the toner bottle information for Bk.

001

Machine Serial ID

*ENG


002

Cartridge Ver

*ENG


003

Brand ID

*ENG


004

Area ID

*ENG


005

Product ID

*ENG


006

Color ID

*ENG


007

Maintenance ID

*ENG


008

New Product Information

*ENG


009

Recycle Counter

*ENG


010

Date

*ENG


011

Serial No.

*ENG


012

Toner Remaining

*ENG


013

EDP Code

*ENG


014

End History

*ENG


015

Refill Information

*ENG


016

Attachment: Total Counter

*ENG


017

Attachment: Color Counter

*ENG


018

End: Total Counter

*ENG


019

End: Color Counter

*ENG


020

Attachment Date

*ENG


021

End Date

*ENG


7932

[Toner Bottle M]

Displays the toner bottle information for M.

001

Machine Serial ID

*ENG


002

Cartridge Ver

*ENG


003

Brand ID

*ENG


004

Area ID

*ENG


005

Product ID

*ENG


006

Color ID

*ENG


007

Maintenance ID

*ENG


008

New Product Information

*ENG


009

Recycle Counter

*ENG


010

Date

*ENG


011

Serial No.

*ENG


012

Toner Remaining

*ENG


013

EDP Code

*ENG


014

End History

*ENG


015

Refill Information

*ENG


016

Attachment: Total Counter

*ENG


017

Attachment: Color Counter

*ENG


018

End: Total Counter

*ENG


019

End: Color Counter

*ENG


020

Attachment Date

*ENG


021

End Date

*ENG


7933

[Toner Bottle C]

Displays the toner bottle information for C.

001

Machine Serial ID

*ENG


002

Cartridge Ver

*ENG


003

Brand ID

*ENG


004

Area ID

*ENG


005

Product ID

*ENG


006

Color ID

*ENG


007

Maintenance ID

*ENG


008

New Product Information

*ENG


009

Recycle Counter

*ENG


010

Date

*ENG


011

Serial No.

*ENG


012

Toner Remaining

*ENG


013

EDP Code

*ENG


014

End History

*ENG


015

Refill Information

*ENG


016

Attachment: Total Counter

*ENG


017

Attachment: Color Counter

*ENG


018

End: Total Counter

*ENG


019

End: Color Counter

*ENG


020

Attachment Date

*ENG


021

End Date

*ENG


7934

[Toner Bottle Y]

Displays the toner bottle information for Y.

001

Machine Serial ID

*ENG


002

Cartridge Ver

*ENG


003

Brand ID

*ENG


004

Area ID

*ENG


005

Product ID

*ENG


006

Color ID

*ENG


007

Maintenance ID

*ENG


008

New Product Information

*ENG


009

Recycle Counter

*ENG


010

Date

*ENG


011

Serial No.

*ENG


012

Toner Remaining

*ENG


013

EDP Code

*ENG


014

End History

*ENG


015

Refill Information

*ENG


016

Attachment: Total Counter

*ENG


017

Attachment: Color Counter

*ENG


018

End: Total Counter

*ENG


019

End: Color Counter

*ENG


020

Attachment Date

*ENG


021

End Date

*ENG


7935

[Toner Bottle Log 1/2/3/4/5: Bk]

001

Serial No.

*ENG

Displays the toner bottle information log 1 for Bk.

002

Attachment Date

003

Attachment: Total Counter

004

Refill Information

011

Serial No.

*ENG

Displays the toner bottle information log 2 for Bk.

012

Attachment Date

013

Attachment: Total Counter

014

Refill Information

021

Serial No.

*ENG

Displays the toner bottle information log 3 for Bk.

022

Attachment Date

023

Attachment: Total Counter

024

Refill Information

031

Serial No.

*ENG

Displays the toner bottle information log 4 for Bk.

032

Attachment Date

033

Attachment: Total Counter

034

Refill Information

041

Serial No.

*ENG

Displays the toner bottle information log 5 for Bk.

042

Attachment Date

043

Attachment: Total Counter

044

Refill Information

7936

[Toner Bottle Log 1/2/3/4/5: M]

001

Serial No.

*ENG

Displays the toner bottle information log 1 for M.

002

Attachment Date

003

Attachment: Total Counter

004

Refill Information

011

Serial No.

*ENG

Displays the toner bottle information log 2 for M.

012

Attachment Date

013

Attachment: Total Counter

014

Refill Information

021

Serial No.

*ENG

Displays the toner bottle information log 3 for M.

022

Attachment Date

023

Attachment: Total Counter

024

Refill Information

031

Serial No.

*ENG

Displays the toner bottle information log 4 for M.

032

Attachment Date

033

Attachment: Total Counter

034

Refill Information

041

Serial No.

*ENG

Displays the toner bottle information log 5 for M.

042

Attachment Date

043

Attachment: Total Counter

044

Refill Information

7937

[Toner Bottle Log 1/2/3/4/5: C]

001

Serial No.

*ENG

Displays the toner bottle information log 1 for C.

002

Attachment Date

003

Attachment: Total Counter

004

Refill Information

011

Serial No.

*ENG

Displays the toner bottle information log 2 for C.

012

Attachment Date

013

Attachment: Total Counter

014

Refill Information

021

Serial No.

*ENG

Displays the toner bottle information log 3 for C.

022

Attachment Date

023

Attachment: Total Counter

024

Refill Information

031

Serial No.

*ENG

Displays the toner bottle information log 4 for C.

032

Attachment Date

033

Attachment: Total Counter

034

Refill Information

041

Serial No.

*ENG

Displays the toner bottle information log 5 for C.

042

Attachment Date

043

Attachment: Total Counter

044

Refill Information

7938

[Toner Bottle Log 1/2/3/4/5: Y]

001

Serial No.

*ENG

Displays the toner bottle information log 1 for Y.

002

Attachment Date

003

Attachment: Total Counter

004

Refill Information

011

Serial No.

*ENG

Displays the toner bottle information log 2 for Y.

012

Attachment Date

013

Attachment: Total Counter

014

Refill Information

021

Serial No.

*ENG

Displays the toner bottle information log 3 for Y.

022

Attachment Date

023

Attachment: Total Counter

024

Refill Information

031

Serial No.

*ENG

Displays the toner bottle information log 4 for Y.

032

Attachment Date

033

Attachment: Total Counter

034

Refill Information

041

Serial No.

*ENG

Displays the toner bottle information log 5 for Y.

042

Attachment Date

043

Attachment: Total Counter

044

Refill Information

7950

[Unit Replacement Date]

001

Image Transfer Belt

*ENG

Displays the replacement date of each PM unit.

002

Cleaning Unit

003

Paper Transfer Unit

004

Fusing Unit

005

Toner Collection Bottle

006

PCDU:Bk (Drum Unit)

*ENG

Displays the replacement date of each PM unit.

007

PCDU:M (Drum Unit)

008

PCDU:C (Drum Unit)

009

PCDU:Y (Drum Unit)

010

Fusing Roller

011

Pressure Roller

7951

[Remaining Day Counter]

Displays the remaining unit life of each PM unit.

001

Page: PCU (Drum): Bk

-

[0 to 255 / 255 / 1 day/step]

002

Page: PCU (Drum): M

-

003

Page: PCU (Drum): C

-

004

Page: PCU (Drum): Y

-

005

Page: Development Unit: Bk

-

006

Page: Development Unit: M

-

007

Page: Development Unit: C

-

008

Page: Development Unit: Y

-

009

Page: Developer: Bk

-

010

Page: Developer: M

-

011

Page: Developer: C

-

012

Page: Developer: Y

-

013

Page: Image Transfer

-

[0 to 255 / 255 / 1 day/step]

014

Page: Cleaning Unit

015

Page: Fusing Unit

016

Page: Paper Transfer Unit

017

Page: Fusing Roller

018

Page: Pressure Roller

031

Rotation: PCU (Drum): Bk

-

[0 to 255 / 255 / 1 day/step]

032

Rotation: PCU (Drum): M

033

Rotation: PCU (Drum): C

034

Rotation: PCU (Drum): Y

035

Rotation: Development Unit: Bk

036

Rotation: Development Unit: M

037

Rotation: Development Unit: C

038

Rotation: Development Unit: Y

039

Rotation: Developer: Bk

040

Rotation: Developer: M

041

Rotation: Developer: C

042

Rotation: Developer: Y

043

Rotation: Image Transfer

-

[0 to 255 / 255 / 1 day/step]

044

Rotation: Cleaning Unit

045

Rotation: Fusing Unit

046

Rotation: Paper Transfer Unit

047

Measurement: Toner Collection bottle

048

Page: Fusing Roller

049

Page: Pressure Roller

7952

[PM Yield Setting]

Adjusts the unit yield of each PM unit.

001

Rotation: Image Transfer Belt

*CTL

[0 to 999999999 / 312707000 / 1 mm/step]

002

Rotation: Cleaning Unit

*CTL

[0 to 999999999 / 104236000 / 1 mm/step]

003

Rotation: Fusing Unit

*CTL

[0 to 999999999 / 172023000 / 1 mm/step]

004

Rotation: Paper Transfer Unit

*CTL

[0 to 999999999 / 156354000 / 1 mm/step]

011

Page: Image Transfer Belt

*CTL

[0 to 999999 / 600000 / 1 sheet/step]

012

Page: Cleaning Unit

*CTL

[0 to 999999 / 200000 / 1 sheet/step]

013

Page: Fusing Unit

*CTL

[0 to 999999 / 300000 / 1 sheet/step]

014

Page: Paper Transfer Unit

*CTL

[0 to 999999 / 300000 / 1 sheet/step]

021

Day Threshold: PCU (Drum): Bk

*CTL

Adjusts the threshold day for the near end fro each PM unit.

[1 to 30 / 15 / 1 day/step]

These threshold days are used for @Remote alarms.

022

Day Threshold: PCU (Drum): M

023

Day Threshold: PCU (Drum): C

024

Day Threshold: PCU (Drum): Y

025

Day Threshold: Development Unit: Bk

026

Day Threshold: Development Unit: M

027

Day Threshold: Development Unit: C

028

Day Threshold: Development Unit: Y

029

Day Threshold: Developer: Bk

*CTL

Adjusts the threshold day for the near end fro each PM unit.

[1 to 30 / 15 / 1 day/step]

These threshold days are used for @Remote alarms.

030

Day Threshold: Developer: M

031

Day Threshold: Developer: C

032

Day Threshold: Developer: Y

033

Day Threshold: Image Transfer Belt

034

Day Threshold: Cleaning Unit

035

Day Threshold: Fusing Unit

036

Day Threshold: PTR Unit

037

Day Threshold: Toner Collection Bottle

038

Rotation: PCU (Drum Unit): Bk

*CTL

[0 to 999999999 / 0 / 1 mm/step]

039

Rotation: PCU (Drum Unit): M

040

Rotation: PCU (Drum Unit): C

041

Rotation: PCU (Drum Unit): Y

042

Rotation: Development Unit: Bk

*CTL

[0 to 999999999 / 0 / 1 mm/step]

043

Rotation: Development Unit: M

044

Rotation: Development Unit: C

045

Rotation: Development Unit: Y

046

Rotation: Developer: Bk

*CTL

[0 to 999999999 / 0 / 1 mm/step]

047

Rotation: Developer: M

048

Rotation: Developer: C

049

Rotation: Developer: Y

050

Page: PCU (Drum Unit): Bk

*CTL

[0 to 999999 / 0 / 1 sheet/step]

051

Page: PCU (Drum Unit): M

052

Page: PCU (Drum Unit): C

053

Page: PCU (Drum Unit): Y

054

Page: Development Unit: Bk

*CTL

[0 to 999999 / 0 / 1 sheet/step]

055

Page: Development Unit: M

056

Page: Development Unit: C

057

Page: Development Unit: Y

058

Page: Developer: Bk

*CTL

[0 to 999999 / 0 / 1 sheet/step]

059

Page: Developer: M

060

Page: Developer: C

061

Page: Developer: Y

7953

[Operation Env. Log: PCDU: Bk]


Displays the PCDU rotation distance in each specified operation environment.

T: Temperature (C), H: Relative Humidity (%)

001

T<=5: 0<=H<30

*CTL

[0 to 99999999 / - / 1 mm/step]

002

T<=5: 30<=H<55

*CTL


003

T<=5: 55<=H<80

*CTL


004

T<=5: 80<=H<=100

*CTL


005

5<T<15: 0<=H<30

*CTL


006

5<T<15: 30<=H<55

*CTL


007

5<T<15: 55<=H<80

*CTL


008

5<T<15: 80<=H<=100

*CTL


009

15<=T<25: 0<=H<30

*CTL


010

15<=T<25: 30<=H<55

*CTL


011

15<=T<25: 55<=H<80

*CTL


012

15<=T<25: 80<=H<=100

*CTL


013

25<=T<30: 0<=H<30

*CTL


014

25<=T<30: 30<=H<55

*CTL


015

25<=T<30: 55<=H<80

*CTL


016

25<=T<30: 80<=H<=100

*CTL


017

30<=T: 0<=H<30

*CTL


018

30<=T: 30<=H<55

*CTL


019

30<=T: 55<=H<80

*CTL


020

30<=T: 80<=H<=100

*CTL


7954

[Operation Env. Log Clear]

Clears the operation environment log.

001




7955

[Fusing: Stop] Not Used