Skip header
 

Before Removing the Old PM Parts

  1. Enter the SP mode.

  2. Output the SMC logging data with SP5-990-004.

  3. Set the following SPs to "1" before you turn the power off. Then, the machine will reset the PM counters automatically. In the case of developer, the developer initialization will also be done automatically.

  4. Exit the SP mode.

Item

SP

Developer

Black: 3902-005

Yellow: 3902-006

Cyan: 3902-007

Magenta: 3902-008

Drum Unit

Black: 3902-009

Yellow: 3902-010

Cyan: 3902-011

Magenta: 3902-012

Heating Roller and Pressure Roller (not necessary for complete fusing units; see below)

Heating roller: 3902-018

Pressure roller: 3902-019

Image Transfer Belt Cleaning Unit

3902-015

PTR Unit

3902-016

Toner Collection Bottle (if not full or near-full)

3902-017

For the following units, there is a new unit detection mechanism. It is not necessary to reset PM counters.