A: Leading Edge Registration
Put the test chart on the exposure glass. Then make a copy from one of the feed stations.
Check the leading edge and side-to-side registration. Adjust the following SP modes if necessary.
Standard: 0 ± 2mm for the leading edge registration, 0 ± 2.5mm for the side-to-side registration.
SP mode |
|
Leading Edge Registration |
SP4-010-001 |
Side-to-Side Registration |
SP4-011-001 |