3011 |
[Process Cont. Manual Execution] |
||
001 |
Normal |
- |
Executes the normal process control manually (potential control). Check the result with SP3-325-001 and 3-012-001 after executing this SP. |
002 |
Density Adjustment |
- |
Executes the toner density adjustment manually. |
003 |
Pre-ACC |
- |
Executes the process control that is normally done before ACC. The type of process control is selected with SP3-041-004. |
004 |
Full MUSIC |
- |
Executes the process control that is normally done at the same time as MUSIC. This SP does the MUSIC (line position adjustment) twice. |
005 |
Normal MUSIC |
- |
Executes the process control that is normally done at the same time as MUSIC. This SP does the MUSIC (line position adjustment) once. |
3012 |
[Process Cont. Check Result] Process Control Self-check Result |
||
Displays the result of the latest process control self-check. All colors are displayed. The results are displayed in the order “Y C M K” e.g., 11 (Y) 99 (C) 11 (M) 11 (K): The self-check for Cyan failed but the others were successful. See the "Error Condition Tables" in the "Appendix: Process Control Error Conditions" section for details. |
|||
001 |
History: Latest |
*ENG |
[1111 to 99999999 / 99999999 / 1/step] |
002 |
Result: Latest 1 |
*ENG |
|
003 |
Result: Latest 2 |
*ENG |
|
004 |
Result: Latest 3 |
*ENG |
|
005 |
Result: Latest 4 |
*ENG |
|
006 |
Result: Latest 5 |
*ENG |
|
007 |
Result: Latest 6 |
*ENG |
|
008 |
Result: Latest 7 |
*ENG |
|
009 |
Result: Latest 8 |
*ENG |
|
010 |
Result: Latest 9 |
*ENG |
3013 |
[T Sensor Initial Set: Execution] Developer Initialization Setting |
||
001 |
Execution: ALL |
- |
Executes the developer initialization for each color. |
002 |
Execution: COL |
- |
|
003 |
Execution: Bk |
- |
|
004 |
Execution: M |
- |
|
005 |
Execution: C |
- |
|
006 |
Execution: Y |
- |
3014 |
[T Sensor Initial Set Result: Display] Developer Initialization Result: Display |
||
001 |
Display: YCMK |
*ENG |
[0 to 9999 / 9999 / 1 /step ] 1: Success, 2 to 9: Failure |
Displays the developer initialization result. See section "Developer Initialization Result" in the "Appendix: Process Control Error Conditions" section for details on the meaning of each code. All colors are displayed. Values are displayed in the order Y C M Bk. e.g., 1 (Y) 2 (C) 1 (M) 1 (Bk): Initialization of Cyan failed but the others succeeded. |
3015 |
[Forced Toner Supply: Execute] Forced Toner Supply ([Color]) |
||
001 |
Execution: ALL |
- |
Executes the manual toner supply to the development unit. |
002 |
Execution: COL |
- |
|
003 |
Execution: Bk |
- |
|
004 |
Execution: M |
- |
|
005 |
Execution: C |
- |
|
006 |
Execution: Y |
- |
3016 |
[Forced Toner Supply: Setting] Forced Toner Supply Setting ([Color]) |
||
Specifies the manual toner supply time for each color. |
|||
001 |
Supply Time: Bk |
*ENG |
[0 to 30 / 4 / 1 sec/step] |
002 |
Supply Time: M |
*ENG |
|
003 |
Supply Time: C |
*ENG |
|
004 |
Supply Time: Y |
*ENG |
3041 |
[Process Control Type] |
||
001 |
Voltage Control |
*ENG |
[0 or 1 / 1 / 1/step ] Alphanumeric 0: FIXED (Use the fixed values for the charge DC bias and development DC bias set with SP2-005 and SP2-229.) 1: CONTROL |
Enables or disables potential control. |
|||
002 |
LD Power Control |
*ENG |
[0 or 1 / 1 / 1/step] Alphanumeric 0: FIXED (at the value in SP2221-xxx) 1: CONTROL (adjusted by process control) |
Selects the LD power control mode. |
|||
003 |
AutoControl Prohibition Set |
*ENG |
[0 or 1 / 0 / -] 0: Permit, 1: Forbid |
Enables or disables the automatic process control prohibition. |
|||
004 |
Pre-ACC |
*ENG |
[0 to 2 / 2 / 1/step] 0: Not Executed 1: Process Control 2: TC Control (TD Adjustment) 3: Not used |
Selects the process control mode that is done before ACC. |
|||
005 |
Pattern Calculation Method |
*ENG |
[0 to 2 / 2 / 1/step] 0: FIXED 1: INITIALIZED 2: CALCULATED |
Selects the process control method. |
3043 |
[TD Adjustment Mode] |
||||||||||
001 |
Repeat Number: Power ON |
*ENG |
[0 to 9 / 4 / 1 time/step] |
||||||||
Specifies the maximum number of repeats of the toner density adjustment at power on. 0: Disabled, 1 to 3: Repeat number, 4: Repeat three times (No consumption mode) 5: Repeat three times (Toner is supplied only when the toner density is too low, and toner is consumed only when the toner density is too dark.) 6 to 9: Disabled |
|||||||||||
002 |
Repeat Number: Initialization |
*ENG |
[0 to 9 / 3 / 1 time/step] |
||||||||
Specifies the maximum number of repeats of the toner density adjustment at the developer initialization. 0: Disabled, 1 to 3: Repeat number, 4: Repeat three times (No consumption mode) 5: Repeat three times (Toner is supplied only when the toner density is too low, and toner is consumed only when the toner density is too dark.) 6 to 9: Disabled |
|||||||||||
003 |
Repeat Number: Non-use |
*ENG |
[0 to 9 / 0 / 1 time/step] |
||||||||
Specifies the maximum number of repeats of the toner density adjustment in stand by mode. 0: Disabled, 1 to 3: Repeat number, 4: Repeat three times (No consumption mode) 5: Repeat three times (Toner is supplied only when the toner density is too low, and toner is consumed only when the toner density is too dark.) 6 to 9: Disabled |
|||||||||||
004 |
Repeat Number: ACC |
*ENG |
[0 to 9 / 3 / 1 time/step] |
||||||||
Specifies the maximum number of repeats of the toner density adjustment at ACC. 0: Disabled, 1 to 3: Repeat number, 4: Repeat three times (No consumption mode) 5: Repeat three times (Toner is supplied only when the toner density is too low, and toner is consumed only when the toner density is too dark.) 6 to 9: Disabled |
|||||||||||
005 |
Repeat Number: Recovery |
*ENG |
[0 to 9 / 0 / 1 time/step] |
||||||||
Not used |
|||||||||||
006 |
Repeat Number: Job End |
*ENG |
[0 to 9 / 4 / 1 time/step] |
||||||||
Specifies the maximum number of repeats of the toner density adjustment at job end. 0: Disabled, 1 to 3: Repeat number, 4: Repeat three times (No consumption mode) 5: Repeat three times (Toner is supplied only when the toner density is too low, and toner is consumed only when the toner density is too dark.) 6 to 9: Disabled |
|||||||||||
007 |
Repeat: Interrupt |
*ENG |
[0 to 9 / 0 / 1 time/step] |
||||||||
Specifies the maximum number of repeats of the toner density adjustment during printing. DFU |
|||||||||||
008 |
Toner Supply Coefficient |
*ENG |
[0 to 25.5 / 10 / 0.1 sec/step] |
||||||||
Adjusts the time for the toner supply mode when a toner density is detected to be low. |
|||||||||||
009 |
Consumption pattern: Bk |
*ENG |
[0 to 255 / 5 / 1 time/step] |
||||||||
Specifies the belt mark generating time for checking the black toner density when toner density is detected to be low at the toner density adjustment. |
|||||||||||
010 |
Consumption pattern: M |
*ENG |
[0 to 255 / 5 / 1 time/step] |
||||||||
Specifies the belt mark generating time for checking the magenta toner density when toner density is detected to be low at the toner density adjustment. |
|||||||||||
011 |
Consumption pattern: C |
*ENG |
[0 to 255 / 5 / 1 time/step] |
||||||||
Specifies the belt mark generating time for checking the cyan toner density when toner density is detected to be low at the toner density adjustment. |
|||||||||||
012 |
Consumption pattern: Y |
*ENG |
[0 to 255 / 5 / 1 time/step] |
||||||||
Specifies the belt mark generating time for checking the yellow toner density when toner density is detected to be low at the toner density adjustment. |
|||||||||||
013 |
T1 Bias: Bk |
*ENG |
[0 to 80 / 22 / 1 |
||||||||
Adjusts the image transfer belt bias for Black. |
|||||||||||
014 |
T2 Bias: M |
*ENG |
[0 to 80 / 25 / 1 |
||||||||
Adjusts the image transfer belt bias for Magenta. |
|||||||||||
015 |
T3 Bias: C |
*ENG |
[0 to 80 / 22 / 1 |
||||||||
Adjusts the image transfer belt bias for Cyan. |
|||||||||||
016 |
T4 Bias: Y |
*ENG |
[0 to 80 / 28 / 1 |
||||||||
Adjusts the image transfer belt bias for Yellow. |
|||||||||||
017 |
Developer Mixing Time |
*ENG |
[0 to 250 / 10 / 1 sec/step] |
||||||||
Specifies the developer mixing time at the toner density adjustment. |
|||||||||||
018 |
Consumption Pattern: LD: DUTY: Bk |
*ENG |
[0 to 15 / 15 / 1 /step] |
||||||||
Adjusts the LD duty for the toner consumption mode at the toner density adjustment. In toner consumption mode, toner is discharged when the detected development gamma values (SP3611-001) exceed the target values (SP3611-005) by more than the specified thresholds (SP3239-009). |
|||||||||||
019 |
Consumption Pattern: LD: DUTY: M |
*ENG |
[0 to 15 / 15 / 1 /step] |
||||||||
Adjusts the LD duty for the toner consumption mode at the toner density adjustment. In toner consumption mode, toner is discharged when the detected development gamma values (SP3611-002) exceed the target values (SP3611-006) by more than the specified thresholds (SP3239-009). |
|||||||||||
020 |
Consumption Pattern: LD: DUTY: C |
*ENG |
[0 to 15 / 15 / 1 /step] |
||||||||
Adjusts the LD duty for the toner consumption mode at the toner density adjustment. In toner consumption mode, toner is discharged when the detected development gamma values (SP3611-003) exceed the target values (SP3611-007) by more than the specified thresholds (SP3239-009). |
|||||||||||
021 |
Consumption Pattern: LD: DUTY: Y |
*ENG |
[0 to 15 / 15 / 1 /step] |
||||||||
Adjusts the LD duty for the toner consumption mode at the toner density adjustment. In toner consumption mode, toner is discharged when the detected development gamma values (SP3611-004) exceed the target values (SP3611-008) by more than the specified thresholds (SP3239-009). |
3044 |
[Toner Supply Type] Toner Supply Type ([Color]) |
||
Selects the toner supply method type. |
|||
001 |
Bk |
*ENG |
[0 to 3 / 2 / 1/step] Alphanumeric 0: FIXED (with the supply rates stored with SP 3401) 1: PID (Vtref_Fixed) 2: PID (Vtref_Control) 3: Not used |
002 |
M |
*ENG |
|
003 |
C |
*ENG |
|
004 |
Y |
*ENG |
3045 |
[Toner End Detection: Set] |
||
Enables/disables the toner alert display on the LCD. |
|||
001 |
ON/OFF |
*ENG |
[0 or 1 / 0 / 1/step] 0: Detect, 1: Not Detect |
3102 |
[Toner End Recovery] |
||
Adjusts the number of times toner supply is attempted for each color when the TD sensor continues to detect toner end during toner recovery. |
|||
001 |
Repeat: Bk |
*ENG |
[1 to 20 / 5 / 1 time/step] |
002 |
Repeat: M |
*ENG |
|
003 |
Repeat: C |
*ENG |
|
004 |
Repeat: Y |
*ENG |
3131 |
[TE Count m: Display] |
||
Display the number of toner end detections for each color. |
|||
001 |
Bk |
*ENG |
[0 to 99 / 0 / 1 time/step] |
002 |
M |
*ENG |
|
003 |
C |
*ENG |
|
004 |
Y |
*ENG |
3201 |
[TD Sensor: Vt Display] |
||
Display the current voltage of the TD sensor for each color. |
|||
001 |
Current: Bk |
*ENG |
[0 to 5.5 / 0.01 / 0.01 V/step] |
002 |
Current: M |
*ENG |
|
003 |
Current: C |
*ENG |
|
004 |
Current: Y |
*ENG |
3211 |
[Vt Shift: Display/Set] |
||
Adjusts the Vt correction value for each line speed. Thick 1: Middle speed, Thick 2&Fine: Low speed |
|||
001 |
Thick 1 Shift: Bk |
*ENG |
[0 to 5 / 0.35 / 0.01 V/step] |
002 |
Thick 1 Shift: M |
*ENG |
[0 to 5 / 0.33 / 0.01 V/step] |
003 |
Thick 1 Shift: C |
*ENG |
[0 to 5 / 0.28 / 0.01 V/step] |
004 |
Thick 1 Shift: Y |
*ENG |
[0 to 5 / 0.29 / 0.01 V/step] |
005 |
Thick 2 & FINE Shift: Bk |
*ENG |
[0 to 5 / 0.35 / 0.01 V/step] |
006 |
Thick 2 & FINE Shift: M |
*ENG |
[0 to 5 / 0.33 / 0.01 V/step] |
007 |
Thick 2 & FINE Shift: C |
*ENG |
[0 to 5 / 0.28 / 0.01 V/step] |
008 |
Thick 2 & FINE Shift: Y |
*ENG |
[0 to 5 / 0.29 / 0.01 V/step] |
009 |
Mid TCShift: Bk |
*ENG |
[-0.5 to 0.5 / 0 / 0.01 V/step] |
010 |
Mid TCShift: M |
*ENG |
|
011 |
Mid TCShift: C |
*ENG |
|
012 |
Mid TCShift: Y |
*ENG |
|
013 |
Low TCShift: Bk |
*ENG |
[-0.5 to 0.5 / 0 / 0.01 V/step] |
014 |
Low TCShift: M |
*ENG |
|
015 |
Low TCShift: C |
*ENG |
|
016 |
Low TCShift: Y |
*ENG |
3221 |
[Vtcnt: Display/Set] |
||
Displays or adjusts the current Vtcnt value for each color. |
|||
001 |
Current: Bk |
*ENG |
[2 to 5 / 3.86 / 0.01 V/step] |
002 |
Current: M |
*ENG |
|
003 |
Current: C |
*ENG |
|
004 |
Current: Y |
*ENG |
|
005-008 |
Displays or adjusts the Vtcnt value for each color at developer initialization. DFU |
||
005 |
Initial: Bk |
*ENG |
[2 to 5 / 3.86 / 0.01 V/step] |
006 |
Initial: M |
*ENG |
|
007 |
Initial: C |
*ENG |
|
008 |
Initial: Y |
*ENG |
3222 |
[Vtref: Display/Set] |
||
Displays or adjusts the current Vtref value for each color. |
|||
001 |
Current: Bk |
*ENG |
[0 to 5.5 / 3 / 0.01 V/step] |
002 |
Current: M |
*ENG |
|
003 |
Current: C |
*ENG |
|
004 |
Current: Y |
*ENG |
|
005-008 |
Displays or adjusts the Vtref value for each color at developer initialization. DFU |
||
005 |
Initial: Bk |
*ENG |
[0 to 5.5 / 3 / 0.01 V/step] |
006 |
Initial: M |
*ENG |
|
007 |
Initial: C |
*ENG |
|
008 |
Initial: Y |
*ENG |
|
009-012 |
Displays and adjusts Vtref correction by pixel coverage for each color. DFU |
||
009 |
Pixel Correction: Bk |
*ENG |
[-5 to 5.5 / 0 / 0.01 V/step] |
010 |
Pixel Correction: M |
*ENG |
|
011 |
Pixel Correction: C |
*ENG |
|
012 |
Pixel Correction: Y |
*ENG |
3239 |
[Vtref Correction: Setting] |
||
Adjusts the parameter for Vtref correction at the process control. |
|||
001 |
(+)Consumption: Bk |
*ENG |
[0 to 1 / 0.05 / 0.01 V/step] |
002 |
(+)Consumption: M |
*ENG |
|
003 |
(+)Consumption: C |
*ENG |
|
004 |
(+)Consumption: Y |
*ENG |
|
005 |
(-)Consumption: Bk |
*ENG |
|
006 |
(-)Consumption: M |
*ENG |
|
007 |
(-)Consumption: C |
*ENG |
|
008 |
(-)Consumption: Y |
*ENG |
|
009-012 |
Threshold for development gamma rank. |
||
009 |
P Rank 1 Threshold |
*ENG |
[0 to 2 / 0.2 / 0.1 /step] |
010 |
P Rank 2 Threshold |
*ENG |
[0 to 2 / 0.05 / 0.1 /step] |
011 |
P Rank 3 Threshold |
*ENG |
[-2 to 0 / -0.05 / 0.1 /step] |
012 |
P Rank 4 Threshold |
*ENG |
[-2 to 0 / -0.2 / 0.1 /step] |
013-014 |
Threshold for image density rank on the image transfer belt. |
||
013 |
T Rank 1 Threshold |
*ENG |
[-1 to 0 / -0.2 / 0.01 V/step] |
014 |
T Rank 2 Threshold |
*ENG |
[0 to 1 / 0.2 / 0.01 V/step] |
3241 |
[Background Potential Setting] |
||
001 |
Coefficient: Bk |
*ENG |
These are parameters for calculating the charge bias referring to the development bias at process control. [-1000 to 1000 / 0 / 1 /step] DC charge bias = Development bias x (1 + 0.001 x these vales) + SP3-241-005 to -008 |
002 |
Coefficient: M |
*ENG |
|
003 |
Coefficient: C |
*ENG |
|
004 |
Coefficient: Y |
*ENG |
|
005 |
Offset: Bk |
*ENG |
These are additional values for calculating the charge bias referring to the development bias at process control. [0 to 255 / 140 / 1 V/step] DC charge bias = Development bias x (1 + 0.001 x SP3-241-001 to -004) + these values |
006 |
Offset: M |
*ENG |
|
007 |
Offset: C |
*ENG |
|
008 |
Offset: Y |
*ENG |
3242 |
[LD Power Setting] |
||
Adjusts the coefficient for LD power control value at the process control. |
|||
001 |
StdSpd:Coefficient: Bk |
*ENG |
[-1000 to 1000 / 101 / 1 /step] |
002 |
StdSpd:Coefficient: M |
*ENG |
[-1000 to 1000 / 62 / 1 /step] |
003 |
StdSpd:Coefficient: C |
*ENG |
[-1000 to 1000 / 99 / 1 /step] |
004 |
StdSpd:Coefficient: Y |
*ENG |
[-1000 to 1000 / 74 / 1 /step] |
005 |
StdSpd:Offset: Bk |
*ENG |
[-1000 to 1000 / 69 / 1 /step] |
006 |
StdSpd:Offset: M |
*ENG |
[-1000 to 1000 / 95 / 1 /step] |
007 |
StdSpd:Offset: C |
*ENG |
[-1000 to 1000 / 63 / 1 /step] |
008 |
StdSpd:Offset: Y |
*ENG |
[-1000 to 1000 / 82 / 1 /step] |
009 |
MidSpd:coef:Bk |
*ENG |
[-1000 to 1000 / 101 / 1 /step] |
010 |
MidSpd:coef:M |
*ENG |
[-1000 to 1000 / 62 / 1 /step] |
011 |
MidSpd:coef:C |
*ENG |
[-1000 to 1000 / 99 / 1 /step] |
012 |
MidSpd:coef:Y |
*ENG |
[-1000 to 1000 / 74 / 1 /step] |
013 |
MidSpd:offset:Bk |
*ENG |
[-1000 to 1000 / 69 / 1 /step] |
014 |
MidSpd:offset:M |
*ENG |
[-1000 to 1000 / 95 / 1 /step] |
015 |
MidSpd:offset:C |
*ENG |
[-1000 to 1000 / 63 / 1 /step] |
016 |
MidSpd:offset:Y |
*ENG |
[-1000 to 1000 / 82 / 1 /step] |
017 |
LowSpd:Coef:Bk |
*ENG |
[-1000 to 1000 / 81 / 1 /step] |
018 |
LowSpd:Coef:M |
*ENG |
[-1000 to 1000 / 61 / 1 /step] |
019 |
LowSpd:Coef:C |
*ENG |
[-1000 to 1000 / 86 / 1 /step] |
020 |
LowSpd:Coef:Y |
*ENG |
[-1000 to 1000 / 67 / 1 /step] |
021 |
LowSpd:offset:Bk |
*ENG |
[-1000 to 1000 / 82 / 1 /step] |
022 |
LowSpd:offset:M |
*ENG |
[-1000 to 1000 / 92 / 1 /step] |
023 |
LowSpd:offset:C |
*ENG |
[-1000 to 1000 / 68 / 1 /step] |
024 |
LowSpd:offset:Y |
*ENG |
[-1000 to 1000 / 87 / 1 /step] |
3251 |
[Coverage] |
|||||
These (-001 to -016) are coefficients for SP3-222-009 to -012. |
||||||
001 |
Latest Pixel: Bk |
*ENG |
Displays the latest coverage for each color. [0 to 9999 / 0 / 1 cm2/step] |
|||
002 |
Latest Pixel: M |
*ENG |
||||
003 |
Latest Pixel: C |
*ENG |
||||
004 |
Latest Pixel: Y |
*ENG |
||||
005-008 |
Displays the average coverage of each color for the Vtref correction. "Average S" is defined when the number of developed pages does not reach the number specified with SP3251-017. |
|||||
005 |
Average S: Bk |
*ENG |
[0 to 100 / 5 / 0.01 %/step] |
|||
006 |
Average S: M |
*ENG |
||||
007 |
Average S: C |
*ENG |
||||
008 |
Average S: Y |
*ENG |
||||
009-012 |
Displays the average coverage of each color for the Vtref correction. "Average M" is defined when the number of developed pages does not reach the number specified with SP3251-018. |
|||||
009 |
Average M: Bk |
*ENG |
[0 to 100 / 5 / 0.01 %/step] |
|||
010 |
Average M: M |
*ENG |
||||
011 |
Average M: C |
*ENG |
||||
012 |
Average M: Y |
*ENG |
||||
013-016 |
Displays the average coverage of each color for the Vtref correction. "Average L" is defined when the number of developed pages does not reach the number specified with SP3-251-019. |
|||||
013 |
Average L: Bk |
*ENG |
[0 to 100 / 5 / 0.01 %/step] |
|||
014 |
Average L: M |
*ENG |
||||
015 |
Average L: C |
*ENG |
||||
016 |
Average L: Y |
*ENG |
||||
017-019 |
Adjusts the threshold for SP3-251-005 to -016. |
|||||
017 |
Total Page Setting: S |
*ENG |
[1 to 100 / 10 / 1 sheet/step] |
|||
018 |
Total Page Setting: M |
*ENG |
[1 to 500 / 10 / 1 sheet/step] |
|||
019 |
Total Page Setting: L |
*ENG |
[1 to 999 / 50 / 1 sheet/step] |
|||
020-023 |
Adjusts the threshold for SP3-251-024 to -027. |
|||||
020 |
Total Page Setting: S2 |
*ENG |
[1 to 100 / 40 / 1 sheet/step] |
|||
021 |
Total Page Setting: M2 |
*ENG |
[1 to 500 / 10 / 1 sheet/step] |
|||
022 |
Total Page Setting: L2 |
*ENG |
[1 to 999 / 50 / 1 sheet/step] |
|||
024-027 |
Displays the latest coverage ratio for each color. |
|||||
024 |
Latest Coverage: Bk |
*ENG |
[0 to 100 / - / 0.01 %/step] |
|||
025 |
Latest Coverage: M |
*ENG |
||||
026 |
Latest Coverage: C |
*ENG |
||||
027 |
Latest Coverage: Y |
*ENG |
||||
028 |
Displays the threshold of whether to perform developer churning or not. |
|||||
DevMix Threshold |
*ENG |
[0 to 100 / 20 / 1 %/step] |
3311 |
[ID Sensor Detection Value: Voffset] |
||
Displays the ID sensor (regular) offset voltage for Vsg adjustments. |
|||
001 |
Voffset reg: Bk |
*ENG |
[0 to 5 / 0 / 0.01 V/step] |
002 |
Voffset reg: M |
*ENG |
[0 to 5.5 / 0 / 0.01 V/step] |
003 |
Voffset reg: C |
*ENG |
|
004 |
Voffset reg: Y |
*ENG |
|
005-007 |
Displays the ID sensor (diffusion) offset voltage for Vsg adjustments. |
||
005 |
Voffset dif: M |
*ENG |
[0 to 5.5 / 0 / 0.01 V/step] |
006 |
Voffset dif: C |
*ENG |
|
007 |
Voffset dif: Y |
*ENG |
|
008-010 |
Displays the ID sensor offset voltage for Vsg adjustments. |
||
008 |
Voffset TM (Front) |
*ENG |
[0 to 5.5 / 0 / 0.01 V/step] |
009 |
Voffset TM (Center) |
*ENG |
|
010 |
Voffset TM (Rear) |
*ENG |
3321 |
[Vsg Adjustment: Execution] |
||
010 |
P/TM Sensor All |
- |
Execute the ID sensor initialization setting for all sensors |
3322 |
[Vsg Adjustment Result: Vsg] |
||
Displays the result value of the Vsg adjustment for each sensor. |
|||
001 |
Vsg reg: Bk |
*ENG |
[0 to 5.5 / 0 / 0.01 V/step] |
002 |
Vsg reg: M |
*ENG |
|
003 |
Vsg reg: C |
*ENG |
|
004 |
Vsg reg: Y |
*ENG |
|
005 |
Vsg dif: M |
*ENG |
|
006 |
Vsg dif: C |
*ENG |
|
007 |
Vsg dif: Y |
*ENG |
|
008 |
Vsg TM (Front) |
*ENG |
|
009 |
Vsg TM (Center) |
*ENG |
|
010 |
Vsg TM (Rear) |
*ENG |
3325 |
[Vsg Adjustment Result] |
||
Displays the result of the Vsg adjustment. The displayed numbers mean the result of each sensor (sensor for Front, sensor for Bk, sensor for Cyan, sensor for Center, sensor for Magenta, sensor for Yellow and sensor for Rear). |
|||
001 |
History: Latest |
*ENG |
[111 to 999 / 999 / 1 /step] 9: Unexpected error 3: Offset voltage error 2: Vsg adjustment value error 1: O.K |
002 |
Result: Latest 1 |
*ENG |
|
003 |
Result: Latest 2 |
*ENG |
|
004 |
Result: Latest 3 |
*ENG |
|
005 |
Result: Latest 4 |
*ENG |
|
006 |
Result: Latest 5 |
*ENG |
|
007 |
Result: Latest 6 |
*ENG |
|
008 |
Result: Latest 7 |
*ENG |
|
009 |
Result: Latest 8 |
*ENG |
|
010 |
Result: Latest 9 |
*ENG |
3401 |
[Fixed Supply Mode] |
||
Adjusts the toner supply rate in the fixed toner supply mode. |
|||
001 |
Fixed Rate: Bk |
*ENG |
[0 to 100 / 5 / 1 %/step] These SPs are used only when SP3-044 is set to "1". |
002 |
Fixed Rate: M |
*ENG |
|
003 |
Fixed Rate: C |
*ENG |
|
004 |
Fixed Rate: Y |
*ENG |
3411 |
[Toner Supply Rate: Display] |
||
Displays the current toner supply rate. |
|||
001 |
Latest: Bk |
*ENG |
[0 to 100 / - / 1 %/step] |
002 |
Latest: M |
*ENG |
|
003 |
Latest: C |
*ENG |
|
004 |
Latest: Y |
*ENG |
3421 |
[Toner Supply Range] |
||
001 |
Upper Limit: Bk |
*ENG |
Adjusts the toner supply rate during printing. [0 to 100 / 100 / 1%/step] |
002 |
Upper Limit: M |
*ENG |
|
003 |
Upper Limit: C |
*ENG |
|
004 |
Upper Limit: Y |
*ENG |
|
005 |
Minimum Supply Time: Bk |
*ENG |
Adjusts the minimum toner supply time. [0 to 1000 / 0 / 1 msec/step] |
006 |
Minimum Supply Time: M |
*ENG |
|
007 |
Minimum Supply Time: C |
*ENG |
|
008 |
Minimum Supply Time: Y |
*ENG |
3501 |
[Process Control Target M/A] |
||
Adjusts the target M/A. |
|||
001 |
Maximum M/A: Bk |
*ENG |
[0 to 1 / 0.444 / 0.001 mg/cm2/step] |
002 |
Maximum M/A: M |
*ENG |
|
003 |
Maximum M/A: C |
*ENG |
|
004 |
Maximum M/A: Y |
*ENG |
3510 |
[Pixel Adj. Sheet Counter: Display] |
||
Displays the total page counter for each adjustment mode. |
|||
001 |
Potential Control: BW |
*ENG |
[0 to 2000 / 0 / 1 page/step] |
002 |
Potential Control: FC |
*ENG |
|
003 |
Power ON: BW |
*ENG |
|
004 |
Power ON: FC |
*ENG |
|
005 |
MUSIC: BW |
*ENG |
|
006 |
MUSIC: FC |
*ENG |
|
007 |
Vsg Adj. |
*ENG |
|
008 |
Charge AC Control |
*ENG |
|
009 |
MUSIC: Power ON: BW |
*ENG |
|
010 |
MUSIC: Power ON: FC |
*ENG |
3511 |
[Execution Interval: Setting] |
||
Adjusts the threshold for each adjustment mode. |
|||
001 |
Job End: Potential Control: BW |
*ENG |
[0 to 2000 / 250 / 1 page/step] |
002 |
Job End: Potential Control: FC |
*ENG |
[0 to 2000 / 100 / 1 page/step] |
003 |
Interrupt: Potential Control: BW |
*ENG |
[0 to 2000 / 500 / 1 page/step] |
004 |
Interrupt: Potential Control: FC |
*ENG |
[0 to 2000 / 200 / 1 page/step] |
005 |
Initial: Potential Control: BW |
*ENG |
[0 to 2000 / 250 / 1 page/step] |
006 |
Initial: Potential Control: FC |
*ENG |
[0 to 2000 / 100 / 1 page/step] |
007 |
Vsg Adj. Counter |
*ENG |
[0 to 2000 / 0 / 1 page/step] |
008 |
Charge AC Control Counter |
*ENG |
|
019 |
Environmental Correction |
*ENG |
[0 or 1 / 1 / 1 /step] 0: Not Correct (OFF), 1: Correct (ON) |
020 |
Gamma Correction |
*ENG |
[0 or 1 / 1 / 1 /step] 0: Not Correct (OFF), 1: Correct (ON) |
021 |
Non-use Time Correction |
*ENG |
[0 or 1 / 1 / 1 /step] 0: Not Correct (OFF), 1: Correct (ON) |
022 |
Correction Coefficient 1: JE: BW |
*ENG |
[0 to 1 / 0.2 / 0.01 page/step] |
023 |
Correction Coefficient 2: JE: BW |
*ENG |
[0 to 1 / 1 / 0.01/step] |
024 |
Correction Coefficient 1: JE: FC |
*ENG |
[0 to 1 / 0.5 / 0.01/step] |
025 |
Correction Coefficient 2: JE: FC |
*ENG |
[0 to 1 / 1 / 0.01/step] |
026 |
Correction Coefficient 1: Interrupt: BW |
*ENG |
[0 to 1 / 0.1 / 0.01/step] |
027 |
Correction Coefficient 2: Interrupt: BW |
*ENG |
[0 to 1 / 1 / 0.01/step] |
028 |
Correction Coefficient 1: Interrupt: FC |
*ENG |
[0 to 1 / 0.25 / 0.01/step] |
029 |
Correction Coefficient 2: Interrupt: FC |
*ENG |
[0 to 1 / 1 / 0.01/step] |
030 |
Max. Number Correction Threshold |
*ENG |
[0 to 99 / 5 / 1/step] |
031 |
Max. Number Correction Counter |
*ENG |
[0 to 255 / 0 / 1/step] |
3512 |
[Image Quality Adj.: Interval] |
||
Adjusts the timing for execution of process control and line position adjustment. |
|||
001 |
During Job |
*ENG |
[0 to 100 / 30 / 1 page/step] |
002 |
During Stand-by |
*ENG |
[0 to 100 / 10 / 1 minute/step] |
3513 |
[PCU Motor Stop Time: Bk] |
||
Displays the last time that the PCDU motors stopped. These are used for process control execution timing. |
|||
001 |
Year |
*ENG |
[0 to 99 / 0 / 1/step] |
002 |
Month |
*ENG |
[1 to 12 / 1 / 1/step] |
003 |
Date |
*ENG |
[1 to 31 / 1 / 1/step] |
004 |
Hour |
*ENG |
[0 to 23 / 0 / 1/step] |
005 |
Minute |
*ENG |
[0 to 59 / 0 / 1/step] |
3514 |
[Environmental Display: Job End] |
||
Displays the environmental conditions for the last job. These are used for process control execution timing. |
|||
001 |
Temperature |
*ENG |
[-1280 to 1270 / 0 / 0.1°C/step] |
002 |
Relative Humidity |
*ENG |
[0 to 1000 / - / 0.1%RH/step] |
003 |
Absolute Humidity |
*ENG |
[0 to 1000 / - / 0.1 g/cm3/step] |
3515 |
[Execution Interval: Display] |
||
Displays the current interval for process control execution. When the machine calculates the timing for process control, it uses a number of conditions. These are the results after considering all the conditions. |
|||
001 |
Job End: Potential Control: BW |
*ENG |
[0 to 2000 / 500 / 1 page/step] |
002 |
Job End: Potential Control: FC |
*ENG |
[0 to 2000 / 200 / 1 page/step] |
003 |
Interrupt: Potential Control: BW |
*ENG |
[0 to 2000 / 500 / 1 page/step] |
004 |
Interrupt: Potential Control: FC |
*ENG |
[0 to 2000 / 200 / 1 page/step] |
3517 |
[Blade damage prevention mode] |
||
Adjusts the threshold temperature for preventing the cleaning blade in the transfer belt cleaning unit from being damaged. If the temperature is above this value, toner is applied to the transfer belt at set intervals during the job to prevent the blade from flipping over. |
|||
001 |
Execution Temp. Threshold |
*ENG |
[0 to 50 / 40 / 1°C/step] |
3519 |
[Toner End Prohibition Setting] |
||
Enables or disables each adjustment at toner near end. |
|||
001 |
Process Control |
*ENG |
[0 or 1 / 1 / 1/step] 0: Permit (adjustment is done even toner near end condition) 1: Forbid (adjustment is not done at toner near end condition) |
002 |
MUSIC |
*ENG |
|
003 |
TC Adj. |
*ENG |
3520 |
[ITB Idling Number] |
||
Specifies the number of the ITB idling rotation for each condition. |
|||
001 |
Temperature: H |
*ENG |
[0 or 3 / 0 / 1 revolution/step] |
002 |
Temperature: M |
*ENG |
|
003 |
Temperature: L |
*ENG |
|
004 |
Temperature: L: Power ON |
*ENG |
3521 |
[Temperature Threshold] |
||
Specifies the threshold temperature for each condition. These settings affect the conditions of SP3-520. t1: Threshold between L (low temp.) and M (medium temp.) t2: Threshold between M (medium temp.) and H (high temps) |
|||
001 |
Threshold: t2 |
*ENG |
[20 or 30 / 25 / 1 deg/step] |
002 |
Threshold: t1 |
*ENG |
[0 or 15 / 15 / 1 deg/step] |
3522 |
[Initial Process Control Setting] |
||
Adjusts the threshold for the process control at power on. When the current condition has changed by more than the values of these SPs when compared with the conditions at the previous operation, the process control at power on is executed. |
|||
002 |
Non-use Time Setting |
*ENG |
[0 to 1440 / 360 / 1 minute/step] |
003 |
Temperature Range |
*ENG |
[0 to 99 / 10 / 1°C/step] |
004 |
Relative Humidity Range |
*ENG |
[0 to 99 / 50 / 1 %RH/step] |
005 |
Absolute Humidity Range |
*ENG |
[0 to 99 / 6 / 1 g/m3/step] |
100 |
[Rapi_timer] |
||
Time Setting |
*ENG |
[0 to 255 / 30 / 1 sec/step] |
|
Adjusts the time-out time for the Rapi timer. |
3531 |
[Non-use Time Process Control Setting] |
||
Adjusts the threshold for the process control at stand-by. When the current condition has changed by more than the values of these SPs when compared with the conditions at the previous operation, the process control at stand-by is executed. |
|||
001 |
Non-use Time Setting |
*ENG |
[0 to 1440 / 360 / 1 minute/step] |
002 |
Temperature Range |
*ENG |
[0 to 99 / 10 / 1°C/step] |
003 |
Relative Humidity Range |
*ENG |
[0 to 99 / 50 / 1 %RH/step] |
004 |
Absolute Humidity Range |
*ENG |
[0 to 99 / 6 / 1 g/m3/step] |
005 |
Maximum Execution Number |
*ENG |
Adjusts the maximum execution time for the process control at stand-by. [0 to 99 / 10 / 1 time/step] |
3611 |
[Development Gamma: Display/Set] |
||
001 |
Bk (Current) |
*ENG |
Displays the current development gamma for each color. [0 to 5 / - / 0.01 mg/cm2/kV /step] |
002 |
M (Current) |
*ENG |
|
003 |
C (Current) |
*ENG |
|
004 |
Y (Current) |
*ENG |
|
005 |
Bk (Target Display) |
*ENG |
Displays the target development gamma for each color. [0 to 5 / 0.91 / 0.01 mg/cm2/kV /step] |
006 |
M (Target Display) |
*ENG |
|
007 |
C (Target Display) |
*ENG |
|
008 |
Y (Target Display) |
*ENG |
|
009 |
Bk (Standard Target Set) |
*ENG |
Displays the standard target development gamma for each color. [0 to 5 / 0.8 / 0.01 mg/cm2/kV /step] |
010 |
M (Standard Target Set) |
*ENG |
|
011 |
C (Standard Target Set) |
*ENG |
|
012 |
Y (Standard Target Set) |
*ENG |
|
013 |
Environmental Correction |
*ENG |
Turns on or off the environmental correction for target development gamma. [0 or 1 / 1 / - ] 0: Not Correct, 1: Correct |
014 |
K (Max Correction) |
*ENG |
Adjusts the maximum correction value for each color. These SPs are effective only when the setting of SP3-611-013 is set to "1". [0 to 5 / 0.15 / 0.01 mg/cm2/kv/ step] |
015 |
M (Max Correction) |
*ENG |
|
016 |
C (Max Correction) |
*ENG |
|
017 |
Y (Max Correction) |
*ENG |
|
018 |
K (Max Abs Hum) |
*ENG |
Adjusts the maximum humidity correction value for each color. These SPs are effective only when the setting of SP3-611-013 is set to "1". [1 to 99 / 20 / 1 g/m3/step] |
019 |
M (Max Abs Hum) |
*ENG |
|
020 |
C (Max Abs Hum) |
*ENG |
|
021 |
Y (Max Abs Hum) |
*ENG |
3612 |
[Vk Display] |
||
Displays Vk for each color. |
|||
001 |
Bk |
*ENG |
[-300 to 300 / - / 1 V/step] |
002 |
M |
*ENG |
|
003 |
C |
*ENG |
|
004 |
Y |
*ENG |
3621 |
[Development DC Control: Display] Plain: High speed, Thick 1: Middle speed, Thick 2 & FINE: Low speed |
||
Displays the development DC bias adjusted with the process control for each line speed and color. |
|||
001 |
Plain: Bk |
*ENG |
[0 to 700 / 550 / 1 -V/step] |
002 |
Plain: M |
*ENG |
|
003 |
Plain: C |
*ENG |
|
004 |
Plain: Y |
*ENG |
|
005 |
Thick 1: Bk |
*ENG |
[0 to 700 / 550 / 1 -V/step] |
006 |
Thick 1: M |
*ENG |
|
007 |
Thick 1: C |
*ENG |
|
008 |
Thick 1: Y |
*ENG |
|
009 |
Thick 2 & FINE: Bk |
*ENG |
[0 to 700 / 550 / 1 -V/step] |
010 |
Thick 2 & FINE: M |
*ENG |
|
011 |
Thick 2 & FINE: C |
*ENG |
|
012 |
Thick 2 & FINE: Y |
*ENG |
3631 |
[Charge DC Control: Display] Plain: High speed, Thick 1: Middle speed, Thick 2 & FINE: Low speed |
||
Displays the charge DC voltage adjusted with the process control for each line speed and color. |
|||
001 |
Plain: Bk |
*ENG |
[0 to 2000 / 690 / 1 -V/step] |
002 |
Plain: M |
*ENG |
|
003 |
Plain: C |
*ENG |
|
004 |
Plain: Y |
*ENG |
|
005 |
Thick 1 & FINE: Bk |
*ENG |
[0 to 2000 / 690 / 1 -V/step] |
006 |
Thick 1 & FINE: M |
*ENG |
|
007 |
Thick 1 & FINE: C |
*ENG |
|
008 |
Thick 1& FINE: Y |
*ENG |
|
009 |
Thick 2 & FINE: Bk |
*ENG |
[0 to 2000 / 690 / 1 -V/step] |
010 |
Thick 2 & FINE: M |
*ENG |
|
011 |
Thick 2 & FINE: C |
*ENG |
|
012 |
Thick 2 & FINE: Y |
*ENG |
3641 |
[Charge AC Control: Display] Plain: High speed |
||
Displays the charge AC voltage adjusted with the process control for each color. |
|||
001 |
Plain: Bk |
*ENG |
[0 to 3 / 1.75 / 0.01 kV/step] |
002 |
Plain: M |
*ENG |
|
003 |
Plain: C |
*ENG |
|
004 |
Plain: Y |
*ENG |
3651 |
[LD Power Control: Display] Plain: High speed, Thick 1: Middle speed, Thick 2 & FINE: Low speed |
||
Displays the LD power adjusted for each environment. |
|||
001 |
Plain: Bk |
*ENG |
[0 to 200 / 100 / 1 %/step] |
002 |
Plain: M |
*ENG |
|
003 |
Plain: C |
*ENG |
|
004 |
Plain: Y |
*ENG |
|
005 |
Thick 1: Bk |
*ENG |
[0 to 200 / 100 / 1 %/step] |
006 |
Thick 1: M |
*ENG |
|
007 |
Thick 1: C |
*ENG |
|
008 |
Thick 1: Y |
*ENG |
|
009 |
Thick 2 & FINE: Bk |
*ENG |
[0 to 200 / 100 / 1 %/step] |
010 |
Thick 2 & FINE: M |
*ENG |
|
011 |
Thick 2 & FINE: C |
*ENG |
|
012 |
Thick 2 & FINE: Y |
*ENG |
3710 |
[HST Concentration Control: Set] TD Sensor: Toner Concentration Control Setting |
||
Selects the toner concentration control method by HST memory, which is in the TD sensor. |
|||
001 |
Control Method: Selection |
*ENG |
[0 or 1 / 1 / - ] 0: Not Use, 1: Use |
3711 |
[HST Concentration Control: Bk] |
||
Displays the factory settings of the black PCDU. |
|||
001 |
Vcnt |
*ENG |
[0 to 5 / 4 / 0.1 V/step] |
002 |
Vt |
*ENG |
[0 to 5 / 2.5 / 0.1 V/step] |
003 |
Sensitivity: HL |
*ENG |
[1.22 to 3.77 / 2.1 / 0.01 V/step] |
004 |
Sensitivity: HM |
*ENG |
[0 to 2.55 / 1.05 / 0.01 V/step] |
005 |
Sensitivity: ML |
*ENG |
|
006 |
Set Detection |
*ENG |
[0 to 5 / 1 / 0.1 V/step] |
007 |
Without Developer |
*ENG |
[0 to 5 / 1.2 / 0.1 V/step] |
008 |
With Developer |
*ENG |
[0 to 5 / 1.3 / 0.1 V/step] |
009 |
Serial Number 1 |
*ENG |
[0 to 255 / - / 1 V/step] |
010 |
Serial Number 2 |
*ENG |
|
011 |
Adjustment: Vt |
*ENG |
[0 to 5 / 3 / 0.1 V/step] |
012 |
Adjustment: Vtref |
*ENG |
[0 to 5 / 3 / 0.1 V/step] |
013 |
Adjustment: Vtcnt |
*ENG |
[0 to 5 / 4 / 0.01 V/step] |
014 |
Adjustment: Gamma |
*ENG |
[0 to 2.55 / 0 / 0.01 mg/cm2/kV /step] |
015 |
Adjustment: Vcnt Result |
*ENG |
[0 to 9 / 9 / 1 /step] |
3712 |
[HST Concentration Control: M] |
||
Displays the factory settings of the magenta PCDU. |
|||
001 |
Vcnt |
*ENG |
[0 to 5 / 4 / 0.1 V/step] |
002 |
Vt |
*ENG |
[0 to 5 / 2.5 / 0.1 V/step] |
003 |
Sensitivity: HL |
*ENG |
[1.22 to 3.77 / 2.1 / 0.01 V/step] |
004 |
Sensitivity: HM |
*ENG |
[0 to 2.55 / 1.05 / 0.01 V/step] |
005 |
Sensitivity: ML |
*ENG |
|
006 |
Set Detection |
*ENG |
[0 to 5 / 1 / 0.1 V/step] |
007 |
Without Developer |
*ENG |
[0 to 5 / 1.2 / 0.1 V/step] |
008 |
With Developer |
*ENG |
[0 to 5 / 1.3 / 0.1 V/step] |
009 |
Serial Number 1 |
*ENG |
[0 to 255 / - / 1 V/step] |
010 |
Serial Number 2 |
*ENG |
|
011 |
Adjustment: Vt |
*ENG |
[0 to 5 / 3 / 0.1 V/step] |
012 |
Adjustment: Vtref |
*ENG |
[0 to 5 / 3 / 0.1 V/step] |
013 |
Adjustment: Vtcnt |
*ENG |
[0 to 5 / 4 / 0.01 V/step] |
014 |
Adjustment: Gamma |
*ENG |
[0 to 2.55 / 0 / 0.01 mg/cm2/kV /step] |
015 |
Adjustment: Vcnt Result |
*ENG |
[0 to 9 / 9 / 1 /step] |
3713 |
[HST Concentration Control: C] |
||
Displays the factory settings of the cyan PCDU. |
|||
001 |
Vcnt |
*ENG |
[0 to 5 / 4 / 0.1 V/step] |
002 |
Vt |
*ENG |
[0 to 5 / 2.5 / 0.1 V/step] |
003 |
Sensitivity: HL |
*ENG |
[1.22 to 3.77 / 2.1 / 0.01 V/step] |
004 |
Sensitivity: HM |
*ENG |
[0 to 2.55 / 1.05 / 0.01 V/step] |
005 |
Sensitivity: ML |
*ENG |
|
006 |
Set Detection |
*ENG |
[0 to 5 / 1 / 0.1 V/step] |
007 |
Without Developer |
*ENG |
[0 to 5 / 1.2 / 0.1 V/step] |
008 |
With Developer |
*ENG |
[0 to 5 / 1.3 / 0.1 V/step] |
009 |
Serial Number 1 |
*ENG |
[0 to 255 / - / 1 V/step] |
010 |
Serial Number 2 |
*ENG |
|
011 |
Adjustment: Vt |
*ENG |
[0 to 5 / 3 / 0.1 V/step] |
012 |
Adjustment: Vtref |
*ENG |
[0 to 5 / 3 / 0.1 V/step] |
013 |
Adjustment: Vtcnt |
*ENG |
[0 to 5 / 4 / 0.01 V/step] |
014 |
Adjustment: Gamma |
*ENG |
[0 to 2.55 / 0 / 0.01 mg/cm2/kV /step] |
015 |
Adjustment: Vcnt Result |
*ENG |
[0 to 9 / 9 / 1 /step] |
3714 |
[HST Concentration Control: Y] |
||
Displays the factory settings of the yellow PCDU. |
|||
001 |
Vcnt |
*ENG |
[0 to 5 / 4 / 0.1 V/step] |
002 |
Vt |
*ENG |
[0 to 5 / 2.5 / 0.1 V/step] |
003 |
Sensitivity: HL |
*ENG |
[1.22 to 3.77 / 2.1 / 0.01 V/step] |
004 |
Sensitivity: HM |
*ENG |
[0 to 2.55 / 1.05 / 0.01 V/step] |
005 |
Sensitivity: ML |
*ENG |
|
006 |
Set Detection |
*ENG |
[0 to 5 / 1 / 0.1 V/step] |
007 |
Without Developer |
*ENG |
[0 to 5 / 1.2 / 0.1 V/step] |
008 |
With Developer |
*ENG |
[0 to 5 / 1.3 / 0.1 V/step] |
009 |
Serial Number 1 |
*ENG |
[0 to 255 / - / 1 V/step] |
010 |
Serial Number 2 |
*ENG |
|
011 |
Adjustment: Vt |
*ENG |
[0 to 5 / 3 / 0.1 V/step] |
012 |
Adjustment: Vtref |
*ENG |
[0 to 5 / 3 / 0.1 V/step] |
013 |
Adjustment: Vtcnt |
*ENG |
[0 to 5 / 4 / 0.01 V/step] |
014 |
Adjustment: Gamma |
*ENG |
[0 to 2.55 / 0 / 0.01 mg/cm2/kV /step] |
015 |
Adjustment: Vcnt Result |
*ENG |
[0 to 9 / 9 / 1 /step] |
3800 |
[Toner Collection Bottle Full Detection] |
||
Displays/ adjusts the toner collection bottle detection settings. These SPs are used for NRS. |
|||
001 |
Condition |
*CTL |
[0 to 4 / 0 / 1 /step] |
002 |
Detection Times |
*CTL |
[0 to 50 / - / 1 /step] |
003 |
Print Page After Near Full |
*CTL |
[0 to 1000 / 0 / 1 sheet/step] |
004 |
Pixel Count After Near Full |
*CTL |
[0 to 200000 / - / 1 cm2/step] |
005 |
Pixel Count After Replacement |
*CTL |
Displays the pixel counter after replacement of toner collection bottle. [0 to 200000 / - / 1 cm2/step] |
008 |
Coefficient |
*ENG |
[0.5 to 1.5 / 1 / 0.1 /step] |
011 |
Notice Setting |
*ENG |
Enables or disables the calling for @Remote. [0 or 1 / 1 / - ] 0: Enable @Remote calling 1: Disable @Remote calling |
NOTE: If the toner collection bottle has been replaced before the machine detects used toner near full when this setting is set to "0", the machine cannot detect toner collection bottle near full. In that case, set SP3-902-017 to "1". |
|||
012 |
Day Threshold: Toner Collection bottle:NF |
*ENG |
[1 to 30 / 5 / 1 day/step] |
Sets the threshold days for the near-full display. The near-full of the toner collection bottle is displayed after the toner collection full sensor has detected the actuator in the toner collection bottle. |
|||
013 |
Total:Toner Collection Bottle |
*ENG |
Displays the total amount of the used toner. [0 to 999999999 / - / 1] |
014 |
Mechanism Full Detection Date |
*ENG |
Displays the date of the full detection fot the toner collection bottle. |
3900 |
[Waste Toner Full Detection] |
||
Turns toner collection bottle full detection on or off. |
|||
001 |
ON/OFF Setting |
*ENG |
[0 or 1 / 1 / - ] 0: OFF, 1: ON |
3901 |
[New PCU Detection] |
||
Turns new PCDU detection on or off. |
|||
001 |
ON/OFF Setting |
*ENG |
[0 or 1 / 1 / - ] 0: OFF, 1: ON |
3902 |
[Manual New Unit Set] |
||
Turns the new unit detection flag for each PM unit on or off. |
|||
001 |
Development Unit: Bk |
*ENG |
[0 or 1 / 0 / - ] 0: OFF, 1: ON |
002 |
Development Unit: Y |
*ENG |
|
003 |
Development Unit: C |
*ENG |
|
004 |
Development Unit: M |
*ENG |
|
005 |
Developer: Bk |
*ENG |
[0 or 1 / 0 / - ] 0: OFF, 1: ON |
006 |
Developer: Y |
*ENG |
|
007 |
Developer: C |
*ENG |
|
008 |
Developer: M |
*ENG |
|
009 |
PCU (Drum Unit): Bk |
*ENG |
[0 or 1 / 0 / - ] 0: OFF, 1: ON |
010 |
PCU (Drum Unit): Y |
*ENG |
|
011 |
PCU (Drum Unit): C |
*ENG |
|
012 |
PCU (Drum Unit): M |
*ENG |
|
013 |
Image Transfer Unit |
*ENG |
[0 or 1 / 0 / - ] 0: OFF, 1: ON Do not use 3902-013 if you only change the cleaning unit. 3902-015: This is for the image transfer belt cleaning unit. |
014 |
Fusing Unit |
*ENG |
|
015 |
Cleaning Unit |
*ENG |
|
016 |
Paper Transfer Unit |
*ENG |
|
017 |
Toner Collection Bottle |
*ENG |
|
018 |
Fusing Roller (Heating Roller) |
*ENG |
[0 or 1 / 0 / - ] 0: OFF, 1: ON "Fusing Roller" is designated as "Heating Roller" in this manual. |
019 |
Pressure Roller |
*ENG |