Skip header
 

SP3-XXX (Process)

3011

[Process Cont. Manual Execution]

001

Normal

-

Executes the normal process control manually (potential control).

Check the result with SP3-325-001 and 3-012-001 after executing this SP.

002

Density Adjustment

-

Executes the toner density adjustment manually.

003

Pre-ACC

-

Executes the process control that is normally done before ACC.

The type of process control is selected with SP3-041-004.

004

Full MUSIC

-

Executes the process control that is normally done at the same time as MUSIC. This SP does the MUSIC (line position adjustment) twice.

005

Normal MUSIC

-

Executes the process control that is normally done at the same time as MUSIC. This SP does the MUSIC (line position adjustment) once.

3012

[Process Cont. Check Result] Process Control Self-check Result

Displays the result of the latest process control self-check.

All colors are displayed. The results are displayed in the order “Y C M K”

e.g., 11 (Y) 99 (C) 11 (M) 11 (K): The self-check for Cyan failed but the others were successful.

See the "Error Condition Tables" in the "Appendix: Process Control Error Conditions" section for details.

001

History: Latest

*ENG

[1111 to 99999999 / 99999999 / 1/step]

002

Result: Latest 1

*ENG

003

Result: Latest 2

*ENG

004

Result: Latest 3

*ENG

005

Result: Latest 4

*ENG

006

Result: Latest 5

*ENG

007

Result: Latest 6

*ENG

008

Result: Latest 7

*ENG

009

Result: Latest 8

*ENG

010

Result: Latest 9

*ENG

3013

[T Sensor Initial Set: Execution] Developer Initialization Setting

001

Execution: ALL

-

Executes the developer initialization for each color.

002

Execution: COL

-

003

Execution: Bk

-

004

Execution: M

-

005

Execution: C

-

006

Execution: Y

-

3014

[T Sensor Initial Set Result: Display]

Developer Initialization Result: Display

001

Display: YCMK

*ENG

[0 to 9999 / 9999 / 1 /step ]

1: Success, 2 to 9: Failure

Displays the developer initialization result. See section "Developer Initialization Result" in the "Appendix: Process Control Error Conditions" section for details on the meaning of each code.

All colors are displayed. Values are displayed in the order Y C M Bk.

e.g., 1 (Y) 2 (C) 1 (M) 1 (Bk): Initialization of Cyan failed but the others succeeded.

3015

[Forced Toner Supply: Execute] Forced Toner Supply ([Color])

001

Execution: ALL

-

Executes the manual toner supply to the development unit.

002

Execution: COL

-

003

Execution: Bk

-

004

Execution: M

-

005

Execution: C

-

006

Execution: Y

-

3016

[Forced Toner Supply: Setting] Forced Toner Supply Setting ([Color])

Specifies the manual toner supply time for each color.

001

Supply Time: Bk

*ENG

[0 to 30 / 4 / 1 sec/step]

002

Supply Time: M

*ENG

003

Supply Time: C

*ENG

004

Supply Time: Y

*ENG

3041

[Process Control Type]

001

Voltage Control

*ENG

[0 or 1 / 1 / 1/step ] Alphanumeric

0: FIXED (Use the fixed values for the charge DC bias and development DC bias set with SP2-005 and SP2-229.)

1: CONTROL

Enables or disables potential control.

002

LD Power Control

*ENG

[0 or 1 / 1 / 1/step] Alphanumeric

0: FIXED (at the value in SP2221-xxx)

1: CONTROL (adjusted by process control)

Selects the LD power control mode.

003

AutoControl Prohibition Set

*ENG

[0 or 1 / 0 / -]

0: Permit, 1: Forbid

Enables or disables the automatic process control prohibition.

004

Pre-ACC

*ENG

[0 to 2 / 2 / 1/step]

0: Not Executed

1: Process Control

2: TC Control (TD Adjustment)

3: Not used

Selects the process control mode that is done before ACC.

005

Pattern Calculation Method

*ENG

[0 to 2 / 2 / 1/step]

0: FIXED

1: INITIALIZED

2: CALCULATED

Selects the process control method.

3043

[TD Adjustment Mode]

001

Repeat Number: Power ON

*ENG

[0 to 9 / 4 / 1 time/step]

Specifies the maximum number of repeats of the toner density adjustment at power on.

0: Disabled, 1 to 3: Repeat number,

4: Repeat three times (No consumption mode)

5: Repeat three times (Toner is supplied only when the toner density is too low, and toner is consumed only when the toner density is too dark.)

6 to 9: Disabled

002

Repeat Number: Initialization

*ENG

[0 to 9 / 3 / 1 time/step]

Specifies the maximum number of repeats of the toner density adjustment at the developer initialization.

0: Disabled, 1 to 3: Repeat number,

4: Repeat three times (No consumption mode)

5: Repeat three times (Toner is supplied only when the toner density is too low, and toner is consumed only when the toner density is too dark.)

6 to 9: Disabled

003

Repeat Number: Non-use

*ENG

[0 to 9 / 0 / 1 time/step]

Specifies the maximum number of repeats of the toner density adjustment in stand by mode.

0: Disabled, 1 to 3: Repeat number,

4: Repeat three times (No consumption mode)

5: Repeat three times (Toner is supplied only when the toner density is too low, and toner is consumed only when the toner density is too dark.)

6 to 9: Disabled

004

Repeat Number: ACC

*ENG

[0 to 9 / 3 / 1 time/step]

Specifies the maximum number of repeats of the toner density adjustment at ACC.

0: Disabled, 1 to 3: Repeat number,

4: Repeat three times (No consumption mode)

5: Repeat three times (Toner is supplied only when the toner density is too low, and toner is consumed only when the toner density is too dark.)

6 to 9: Disabled

005

Repeat Number: Recovery

*ENG

[0 to 9 / 0 / 1 time/step]

Not used

006

Repeat Number: Job End

*ENG

[0 to 9 / 4 / 1 time/step]

Specifies the maximum number of repeats of the toner density adjustment at job end.

0: Disabled, 1 to 3: Repeat number,

4: Repeat three times (No consumption mode)

5: Repeat three times (Toner is supplied only when the toner density is too low, and toner is consumed only when the toner density is too dark.)

6 to 9: Disabled

007

Repeat: Interrupt

*ENG

[0 to 9 / 0 / 1 time/step]

Specifies the maximum number of repeats of the toner density adjustment during printing. DFU

008

Toner Supply Coefficient

*ENG

[0 to 25.5 / 10 / 0.1 sec/step]

Adjusts the time for the toner supply mode when a toner density is detected to be low.

009

Consumption pattern: Bk

*ENG

[0 to 255 / 5 / 1 time/step]

Specifies the belt mark generating time for checking the black toner density when toner density is detected to be low at the toner density adjustment.

010

Consumption pattern: M

*ENG

[0 to 255 / 5 / 1 time/step]

Specifies the belt mark generating time for checking the magenta toner density when toner density is detected to be low at the toner density adjustment.

011

Consumption pattern: C

*ENG

[0 to 255 / 5 / 1 time/step]

Specifies the belt mark generating time for checking the cyan toner density when toner density is detected to be low at the toner density adjustment.

012

Consumption pattern: Y

*ENG

[0 to 255 / 5 / 1 time/step]

Specifies the belt mark generating time for checking the yellow toner density when toner density is detected to be low at the toner density adjustment.

013

T1 Bias: Bk

*ENG

[0 to 80 / 22 / 1 _micro.pngA/step]

Adjusts the image transfer belt bias for Black.

014

T2 Bias: M

*ENG

[0 to 80 / 25 / 1 _micro.pngA/step]

Adjusts the image transfer belt bias for Magenta.

015

T3 Bias: C

*ENG

[0 to 80 / 22 / 1 _micro.pngA/step]

Adjusts the image transfer belt bias for Cyan.

016

T4 Bias: Y

*ENG

[0 to 80 / 28 / 1 _micro.pngA/step]

Adjusts the image transfer belt bias for Yellow.

017

Developer Mixing Time

*ENG

[0 to 250 / 10 / 1 sec/step]

Specifies the developer mixing time at the toner density adjustment.

018

Consumption Pattern: LD: DUTY: Bk

*ENG

[0 to 15 / 15 / 1 /step]

Adjusts the LD duty for the toner consumption mode at the toner density adjustment.

In toner consumption mode, toner is discharged when the detected development gamma values (SP3611-001) exceed the target values (SP3611-005) by more than the specified thresholds (SP3239-009).

019

Consumption Pattern: LD: DUTY: M

*ENG

[0 to 15 / 15 / 1 /step]

Adjusts the LD duty for the toner consumption mode at the toner density adjustment.

In toner consumption mode, toner is discharged when the detected development gamma values (SP3611-002) exceed the target values (SP3611-006) by more than the specified thresholds (SP3239-009).

020

Consumption Pattern: LD: DUTY: C

*ENG

[0 to 15 / 15 / 1 /step]

Adjusts the LD duty for the toner consumption mode at the toner density adjustment.

In toner consumption mode, toner is discharged when the detected development gamma values (SP3611-003) exceed the target values (SP3611-007) by more than the specified thresholds (SP3239-009).

021

Consumption Pattern: LD: DUTY: Y

*ENG

[0 to 15 / 15 / 1 /step]

Adjusts the LD duty for the toner consumption mode at the toner density adjustment.

In toner consumption mode, toner is discharged when the detected development gamma values (SP3611-004) exceed the target values (SP3611-008) by more than the specified thresholds (SP3239-009).

3044

[Toner Supply Type] Toner Supply Type ([Color])

Selects the toner supply method type.

001

Bk

*ENG

[0 to 3 / 2 / 1/step] Alphanumeric

0: FIXED (with the supply rates stored with SP 3401)

1: PID (Vtref_Fixed)

2: PID (Vtref_Control)

3: Not used

002

M

*ENG

003

C

*ENG

004

Y

*ENG

3045

[Toner End Detection: Set]

Enables/disables the toner alert display on the LCD.

001

ON/OFF

*ENG

[0 or 1 / 0 / 1/step] 0: Detect, 1: Not Detect

3102

[Toner End Recovery]

Adjusts the number of times toner supply is attempted for each color when the TD sensor continues to detect toner end during toner recovery.

001

Repeat: Bk

*ENG

[1 to 20 / 5 / 1 time/step]

002

Repeat: M

*ENG

003

Repeat: C

*ENG

004

Repeat: Y

*ENG

3131

[TE Count m: Display]

Display the number of toner end detections for each color.

001

Bk

*ENG

[0 to 99 / 0 / 1 time/step]

002

M

*ENG

003

C

*ENG

004

Y

*ENG

3201

[TD Sensor: Vt Display]

Display the current voltage of the TD sensor for each color.

001

Current: Bk

*ENG

[0 to 5.5 / 0.01 / 0.01 V/step]

002

Current: M

*ENG

003

Current: C

*ENG

004

Current: Y

*ENG

3211

[Vt Shift: Display/Set]

Adjusts the Vt correction value for each line speed.

Thick 1: Middle speed, Thick 2&Fine: Low speed

001

Thick 1 Shift: Bk

*ENG

[0 to 5 / 0.35 / 0.01 V/step]

002

Thick 1 Shift: M

*ENG

[0 to 5 / 0.33 / 0.01 V/step]

003

Thick 1 Shift: C

*ENG

[0 to 5 / 0.28 / 0.01 V/step]

004

Thick 1 Shift: Y

*ENG

[0 to 5 / 0.29 / 0.01 V/step]

005

Thick 2 & FINE Shift: Bk

*ENG

[0 to 5 / 0.35 / 0.01 V/step]

006

Thick 2 & FINE Shift: M

*ENG

[0 to 5 / 0.33 / 0.01 V/step]

007

Thick 2 & FINE Shift: C

*ENG

[0 to 5 / 0.28 / 0.01 V/step]

008

Thick 2 & FINE Shift: Y

*ENG

[0 to 5 / 0.29 / 0.01 V/step]

009

Mid TCShift: Bk

*ENG

[-0.5 to 0.5 / 0 / 0.01 V/step]

010

Mid TCShift: M

*ENG

011

Mid TCShift: C

*ENG

012

Mid TCShift: Y

*ENG

013

Low TCShift: Bk

*ENG

[-0.5 to 0.5 / 0 / 0.01 V/step]

014

Low TCShift: M

*ENG

015

Low TCShift: C

*ENG

016

Low TCShift: Y

*ENG

3221

[Vtcnt: Display/Set]

Displays or adjusts the current Vtcnt value for each color.

001

Current: Bk

*ENG

[2 to 5 / 3.86 / 0.01 V/step]

002

Current: M

*ENG

003

Current: C

*ENG

004

Current: Y

*ENG

005-008

Displays or adjusts the Vtcnt value for each color at developer initialization. DFU

005

Initial: Bk

*ENG

[2 to 5 / 3.86 / 0.01 V/step]

006

Initial: M

*ENG

007

Initial: C

*ENG

008

Initial: Y

*ENG

3222

[Vtref: Display/Set]

Displays or adjusts the current Vtref value for each color.

001

Current: Bk

*ENG

[0 to 5.5 / 3 / 0.01 V/step]

002

Current: M

*ENG

003

Current: C

*ENG

004

Current: Y

*ENG

005-008

Displays or adjusts the Vtref value for each color at developer initialization. DFU

005

Initial: Bk

*ENG

[0 to 5.5 / 3 / 0.01 V/step]

006

Initial: M

*ENG

007

Initial: C

*ENG

008

Initial: Y

*ENG

009-012

Displays and adjusts Vtref correction by pixel coverage for each color. DFU

009

Pixel Correction: Bk

*ENG

[-5 to 5.5 / 0 / 0.01 V/step]

010

Pixel Correction: M

*ENG

011

Pixel Correction: C

*ENG

012

Pixel Correction: Y

*ENG

3239

[Vtref Correction: Setting]

Adjusts the parameter for Vtref correction at the process control.

001

(+)Consumption: Bk

*ENG

[0 to 1 / 0.05 / 0.01 V/step]

002

(+)Consumption: M

*ENG

003

(+)Consumption: C

*ENG

004

(+)Consumption: Y

*ENG

005

(-)Consumption: Bk

*ENG

006

(-)Consumption: M

*ENG

007

(-)Consumption: C

*ENG

008

(-)Consumption: Y

*ENG

009-012

Threshold for development gamma rank.

009

P Rank 1 Threshold

*ENG

[0 to 2 / 0.2 / 0.1 /step]

010

P Rank 2 Threshold

*ENG

[0 to 2 / 0.05 / 0.1 /step]

011

P Rank 3 Threshold

*ENG

[-2 to 0 / -0.05 / 0.1 /step]

012

P Rank 4 Threshold

*ENG

[-2 to 0 / -0.2 / 0.1 /step]

013-014

Threshold for image density rank on the image transfer belt.

013

T Rank 1 Threshold

*ENG

[-1 to 0 / -0.2 / 0.01 V/step]

014

T Rank 2 Threshold

*ENG

[0 to 1 / 0.2 / 0.01 V/step]

3241

[Background Potential Setting]

001

Coefficient: Bk

*ENG

These are parameters for calculating the charge bias referring to the development bias at process control.

[-1000 to 1000 / 0 / 1 /step]

DC charge bias = Development bias x (1 + 0.001 x these vales) + SP3-241-005 to -008

002

Coefficient: M

*ENG

003

Coefficient: C

*ENG

004

Coefficient: Y

*ENG

005

Offset: Bk

*ENG

These are additional values for calculating the charge bias referring to the development bias at process control.

[0 to 255 / 140 / 1 V/step]

DC charge bias = Development bias x (1 + 0.001 x SP3-241-001 to -004) + these values

006

Offset: M

*ENG

007

Offset: C

*ENG

008

Offset: Y

*ENG

3242

[LD Power Setting]

Adjusts the coefficient for LD power control value at the process control.

001

StdSpd:Coefficient: Bk

*ENG

[-1000 to 1000 / 101 / 1 /step]

002

StdSpd:Coefficient: M

*ENG

[-1000 to 1000 / 62 / 1 /step]

003

StdSpd:Coefficient: C

*ENG

[-1000 to 1000 / 99 / 1 /step]

004

StdSpd:Coefficient: Y

*ENG

[-1000 to 1000 / 74 / 1 /step]

005

StdSpd:Offset: Bk

*ENG

[-1000 to 1000 / 69 / 1 /step]

006

StdSpd:Offset: M

*ENG

[-1000 to 1000 / 95 / 1 /step]

007

StdSpd:Offset: C

*ENG

[-1000 to 1000 / 63 / 1 /step]

008

StdSpd:Offset: Y

*ENG

[-1000 to 1000 / 82 / 1 /step]

009

MidSpd:coef:Bk

*ENG

[-1000 to 1000 / 101 / 1 /step]

010

MidSpd:coef:M

*ENG

[-1000 to 1000 / 62 / 1 /step]

011

MidSpd:coef:C

*ENG

[-1000 to 1000 / 99 / 1 /step]

012

MidSpd:coef:Y

*ENG

[-1000 to 1000 / 74 / 1 /step]

013

MidSpd:offset:Bk

*ENG

[-1000 to 1000 / 69 / 1 /step]

014

MidSpd:offset:M

*ENG

[-1000 to 1000 / 95 / 1 /step]

015

MidSpd:offset:C

*ENG

[-1000 to 1000 / 63 / 1 /step]

016

MidSpd:offset:Y

*ENG

[-1000 to 1000 / 82 / 1 /step]

017

LowSpd:Coef:Bk

*ENG

[-1000 to 1000 / 81 / 1 /step]

018

LowSpd:Coef:M

*ENG

[-1000 to 1000 / 61 / 1 /step]

019

LowSpd:Coef:C

*ENG

[-1000 to 1000 / 86 / 1 /step]

020

LowSpd:Coef:Y

*ENG

[-1000 to 1000 / 67 / 1 /step]

021

LowSpd:offset:Bk

*ENG

[-1000 to 1000 / 82 / 1 /step]

022

LowSpd:offset:M

*ENG

[-1000 to 1000 / 92 / 1 /step]

023

LowSpd:offset:C

*ENG

[-1000 to 1000 / 68 / 1 /step]

024

LowSpd:offset:Y

*ENG

[-1000 to 1000 / 87 / 1 /step]

3251

[Coverage]

These (-001 to -016) are coefficients for SP3-222-009 to -012.

001

Latest Pixel: Bk

*ENG

Displays the latest coverage for each color.

[0 to 9999 / 0 / 1 cm2/step]

002

Latest Pixel: M

*ENG

003

Latest Pixel: C

*ENG

004

Latest Pixel: Y

*ENG

005-008

Displays the average coverage of each color for the Vtref correction.

"Average S" is defined when the number of developed pages does not reach the number specified with SP3251-017.

005

Average S: Bk

*ENG

[0 to 100 / 5 / 0.01 %/step]

006

Average S: M

*ENG

007

Average S: C

*ENG

008

Average S: Y

*ENG

009-012

Displays the average coverage of each color for the Vtref correction.

"Average M" is defined when the number of developed pages does not reach the number specified with SP3251-018.

009

Average M: Bk

*ENG

[0 to 100 / 5 / 0.01 %/step]

010

Average M: M

*ENG

011

Average M: C

*ENG

012

Average M: Y

*ENG

013-016

Displays the average coverage of each color for the Vtref correction.

"Average L" is defined when the number of developed pages does not reach the number specified with SP3-251-019.

013

Average L: Bk

*ENG

[0 to 100 / 5 / 0.01 %/step]

014

Average L: M

*ENG

015

Average L: C

*ENG

016

Average L: Y

*ENG

017-019

Adjusts the threshold for SP3-251-005 to -016.

017

Total Page Setting: S

*ENG

[1 to 100 / 10 / 1 sheet/step]

018

Total Page Setting: M

*ENG

[1 to 500 / 10 / 1 sheet/step]

019

Total Page Setting: L

*ENG

[1 to 999 / 50 / 1 sheet/step]

020-023

Adjusts the threshold for SP3-251-024 to -027.

020

Total Page Setting: S2

*ENG

[1 to 100 / 40 / 1 sheet/step]

021

Total Page Setting: M2

*ENG

[1 to 500 / 10 / 1 sheet/step]

022

Total Page Setting: L2

*ENG

[1 to 999 / 50 / 1 sheet/step]

024-027

Displays the latest coverage ratio for each color.

024

Latest Coverage: Bk

*ENG

[0 to 100 / - / 0.01 %/step]

025

Latest Coverage: M

*ENG

026

Latest Coverage: C

*ENG

027

Latest Coverage: Y

*ENG

028

Displays the threshold of whether to perform developer churning or not.

DevMix Threshold

*ENG

[0 to 100 / 20 / 1 %/step]

3311

[ID Sensor Detection Value: Voffset]

Displays the ID sensor (regular) offset voltage for Vsg adjustments.

001

Voffset reg: Bk

*ENG

[0 to 5 / 0 / 0.01 V/step]

002

Voffset reg: M

*ENG

[0 to 5.5 / 0 / 0.01 V/step]

003

Voffset reg: C

*ENG

004

Voffset reg: Y

*ENG

005-007

Displays the ID sensor (diffusion) offset voltage for Vsg adjustments.

005

Voffset dif: M

*ENG

[0 to 5.5 / 0 / 0.01 V/step]

006

Voffset dif: C

*ENG

007

Voffset dif: Y

*ENG

008-010

Displays the ID sensor offset voltage for Vsg adjustments.

008

Voffset TM (Front)

*ENG

[0 to 5.5 / 0 / 0.01 V/step]

009

Voffset TM (Center)

*ENG

010

Voffset TM (Rear)

*ENG

3321

[Vsg Adjustment: Execution]

010

P/TM Sensor All

-

Execute the ID sensor initialization setting for all sensors

3322

[Vsg Adjustment Result: Vsg]

Displays the result value of the Vsg adjustment for each sensor.

001

Vsg reg: Bk

*ENG

[0 to 5.5 / 0 / 0.01 V/step]

002

Vsg reg: M

*ENG

003

Vsg reg: C

*ENG

004

Vsg reg: Y

*ENG

005

Vsg dif: M

*ENG

006

Vsg dif: C

*ENG

007

Vsg dif: Y

*ENG

008

Vsg TM (Front)

*ENG

009

Vsg TM (Center)

*ENG

010

Vsg TM (Rear)

*ENG

3325

[Vsg Adjustment Result]

Displays the result of the Vsg adjustment.

The displayed numbers mean the result of each sensor (sensor for Front, sensor for Bk, sensor for Cyan, sensor for Center, sensor for Magenta, sensor for Yellow and sensor for Rear).

001

History: Latest

*ENG

[111 to 999 / 999 / 1 /step]

9: Unexpected error

3: Offset voltage error

2: Vsg adjustment value error

1: O.K

002

Result: Latest 1

*ENG

003

Result: Latest 2

*ENG

004

Result: Latest 3

*ENG

005

Result: Latest 4

*ENG

006

Result: Latest 5

*ENG

007

Result: Latest 6

*ENG

008

Result: Latest 7

*ENG

009

Result: Latest 8

*ENG

010

Result: Latest 9

*ENG

3401

[Fixed Supply Mode]

Adjusts the toner supply rate in the fixed toner supply mode.

001

Fixed Rate: Bk

*ENG

[0 to 100 / 5 / 1 %/step]

These SPs are used only when SP3-044 is set to "1".

002

Fixed Rate: M

*ENG

003

Fixed Rate: C

*ENG

004

Fixed Rate: Y

*ENG

3411

[Toner Supply Rate: Display]

Displays the current toner supply rate.

001

Latest: Bk

*ENG

[0 to 100 / - / 1 %/step]

002

Latest: M

*ENG

003

Latest: C

*ENG

004

Latest: Y

*ENG

3421

[Toner Supply Range]

001

Upper Limit: Bk

*ENG

Adjusts the toner supply rate during printing.

[0 to 100 / 100 / 1%/step]

002

Upper Limit: M

*ENG

003

Upper Limit: C

*ENG

004

Upper Limit: Y

*ENG

005

Minimum Supply Time: Bk

*ENG

Adjusts the minimum toner supply time.

[0 to 1000 / 0 / 1 msec/step]

006

Minimum Supply Time: M

*ENG

007

Minimum Supply Time: C

*ENG

008

Minimum Supply Time: Y

*ENG

3501

[Process Control Target M/A]

Adjusts the target M/A.

001

Maximum M/A: Bk

*ENG

[0 to 1 / 0.444 / 0.001 mg/cm2/step]

002

Maximum M/A: M

*ENG

003

Maximum M/A: C

*ENG

004

Maximum M/A: Y

*ENG

3510

[Pixel Adj. Sheet Counter: Display]

Displays the total page counter for each adjustment mode.

001

Potential Control: BW

*ENG

[0 to 2000 / 0 / 1 page/step]

002

Potential Control: FC

*ENG

003

Power ON: BW

*ENG

004

Power ON: FC

*ENG

005

MUSIC: BW

*ENG

006

MUSIC: FC

*ENG

007

Vsg Adj.

*ENG

008

Charge AC Control

*ENG

009

MUSIC: Power ON: BW

*ENG


010

MUSIC: Power ON: FC

*ENG

3511

[Execution Interval: Setting]

Adjusts the threshold for each adjustment mode.

001

Job End: Potential Control: BW

*ENG

[0 to 2000 / 250 / 1 page/step]

002

Job End: Potential Control: FC

*ENG

[0 to 2000 / 100 / 1 page/step]

003

Interrupt: Potential Control: BW

*ENG

[0 to 2000 / 500 / 1 page/step]

004

Interrupt: Potential Control: FC

*ENG

[0 to 2000 / 200 / 1 page/step]

005

Initial: Potential Control: BW

*ENG

[0 to 2000 / 250 / 1 page/step]

006

Initial: Potential Control: FC

*ENG

[0 to 2000 / 100 / 1 page/step]

007

Vsg Adj. Counter

*ENG

[0 to 2000 / 0 / 1 page/step]

008

Charge AC Control Counter

*ENG

019

Environmental Correction

*ENG

[0 or 1 / 1 / 1 /step]

0: Not Correct (OFF), 1: Correct (ON)

020

Gamma Correction

*ENG

[0 or 1 / 1 / 1 /step]

0: Not Correct (OFF), 1: Correct (ON)

021

Non-use Time Correction

*ENG

[0 or 1 / 1 / 1 /step]

0: Not Correct (OFF), 1: Correct (ON)

022

Correction Coefficient 1: JE: BW

*ENG

[0 to 1 / 0.2 / 0.01 page/step]

023

Correction Coefficient 2: JE: BW

*ENG

[0 to 1 / 1 / 0.01/step]

024

Correction Coefficient 1: JE: FC

*ENG

[0 to 1 / 0.5 / 0.01/step]

025

Correction Coefficient 2: JE: FC

*ENG

[0 to 1 / 1 / 0.01/step]

026

Correction Coefficient 1: Interrupt: BW

*ENG

[0 to 1 / 0.1 / 0.01/step]

027

Correction Coefficient 2: Interrupt: BW

*ENG

[0 to 1 / 1 / 0.01/step]

028

Correction Coefficient 1: Interrupt: FC

*ENG

[0 to 1 / 0.25 / 0.01/step]

029

Correction Coefficient 2: Interrupt: FC

*ENG

[0 to 1 / 1 / 0.01/step]

030

Max. Number Correction Threshold

*ENG

[0 to 99 / 5 / 1/step]

031

Max. Number Correction Counter

*ENG

[0 to 255 / 0 / 1/step]

3512

[Image Quality Adj.: Interval]

Adjusts the timing for execution of process control and line position adjustment.

001

During Job

*ENG

[0 to 100 / 30 / 1 page/step]

002

During Stand-by

*ENG

[0 to 100 / 10 / 1 minute/step]

3513

[PCU Motor Stop Time: Bk]

Displays the last time that the PCDU motors stopped.

These are used for process control execution timing.

001

Year

*ENG

[0 to 99 / 0 / 1/step]

002

Month

*ENG

[1 to 12 / 1 / 1/step]

003

Date

*ENG

[1 to 31 / 1 / 1/step]

004

Hour

*ENG

[0 to 23 / 0 / 1/step]

005

Minute

*ENG

[0 to 59 / 0 / 1/step]

3514

[Environmental Display: Job End]

Displays the environmental conditions for the last job.

These are used for process control execution timing.

001

Temperature

*ENG

[-1280 to 1270 / 0 / 0.1°C/step]

002

Relative Humidity

*ENG

[0 to 1000 / - / 0.1%RH/step]

003

Absolute Humidity

*ENG

[0 to 1000 / - / 0.1 g/cm3/step]

3515

[Execution Interval: Display]

Displays the current interval for process control execution.

When the machine calculates the timing for process control, it uses a number of conditions. These are the results after considering all the conditions.

001

Job End: Potential Control: BW

*ENG

[0 to 2000 / 500 / 1 page/step]

002

Job End: Potential Control: FC

*ENG

[0 to 2000 / 200 / 1 page/step]

003

Interrupt: Potential Control: BW

*ENG

[0 to 2000 / 500 / 1 page/step]

004

Interrupt: Potential Control: FC

*ENG

[0 to 2000 / 200 / 1 page/step]

3517

[Blade damage prevention mode]

Adjusts the threshold temperature for preventing the cleaning blade in the transfer belt cleaning unit from being damaged. If the temperature is above this value, toner is applied to the transfer belt at set intervals during the job to prevent the blade from flipping over.

001

Execution Temp. Threshold

*ENG

[0 to 50 / 40 / 1°C/step]

3519

[Toner End Prohibition Setting]

Enables or disables each adjustment at toner near end.

001

Process Control

*ENG

[0 or 1 / 1 / 1/step]

0: Permit (adjustment is done even toner near end condition)

1: Forbid (adjustment is not done at toner near end condition)

002

MUSIC

*ENG

003

TC Adj.

*ENG

3520

[ITB Idling Number]

Specifies the number of the ITB idling rotation for each condition.

001

Temperature: H

*ENG

[0 or 3 / 0 / 1 revolution/step]

002

Temperature: M

*ENG

003

Temperature: L

*ENG

004

Temperature: L: Power ON

*ENG

3521

[Temperature Threshold]

Specifies the threshold temperature for each condition. These settings affect the conditions of SP3-520.

t1: Threshold between L (low temp.) and M (medium temp.)

t2: Threshold between M (medium temp.) and H (high temps)

001

Threshold: t2

*ENG

[20 or 30 / 25 / 1 deg/step]

002

Threshold: t1

*ENG

[0 or 15 / 15 / 1 deg/step]

3522

[Initial Process Control Setting]

Adjusts the threshold for the process control at power on.

When the current condition has changed by more than the values of these SPs when compared with the conditions at the previous operation, the process control at power on is executed.

002

Non-use Time Setting

*ENG

[0 to 1440 / 360 / 1 minute/step]

003

Temperature Range

*ENG

[0 to 99 / 10 / 1°C/step]

004

Relative Humidity Range

*ENG

[0 to 99 / 50 / 1 %RH/step]

005

Absolute Humidity Range

*ENG

[0 to 99 / 6 / 1 g/m3/step]

100

[Rapi_timer]

Time Setting

*ENG

[0 to 255 / 30 / 1 sec/step]

Adjusts the time-out time for the Rapi timer.

3531

[Non-use Time Process Control Setting]

Adjusts the threshold for the process control at stand-by.

When the current condition has changed by more than the values of these SPs when compared with the conditions at the previous operation, the process control at stand-by is executed.

001

Non-use Time Setting

*ENG

[0 to 1440 / 360 / 1 minute/step]

002

Temperature Range

*ENG

[0 to 99 / 10 / 1°C/step]

003

Relative Humidity Range

*ENG

[0 to 99 / 50 / 1 %RH/step]

004

Absolute Humidity Range

*ENG

[0 to 99 / 6 / 1 g/m3/step]

005

Maximum Execution Number

*ENG

Adjusts the maximum execution time for the process control at stand-by.

[0 to 99 / 10 / 1 time/step]

3611

[Development Gamma: Display/Set]

001

Bk (Current)

*ENG

Displays the current development gamma for each color.

[0 to 5 / - / 0.01 mg/cm2/kV /step]

002

M (Current)

*ENG

003

C (Current)

*ENG

004

Y (Current)

*ENG

005

Bk (Target Display)

*ENG

Displays the target development gamma for each color.

[0 to 5 / 0.91 / 0.01 mg/cm2/kV /step]

006

M (Target Display)

*ENG

007

C (Target Display)

*ENG

008

Y (Target Display)

*ENG

009

Bk (Standard Target Set)

*ENG

Displays the standard target development gamma for each color.

[0 to 5 / 0.8 / 0.01 mg/cm2/kV /step]

010

M (Standard Target Set)

*ENG

011

C (Standard Target Set)

*ENG

012

Y (Standard Target Set)

*ENG

013

Environmental Correction

*ENG

Turns on or off the environmental correction for target development gamma.

[0 or 1 / 1 / - ]

0: Not Correct, 1: Correct

014

K (Max Correction)

*ENG

Adjusts the maximum correction value for each color. These SPs are effective only when the setting of SP3-611-013 is set to "1".

[0 to 5 / 0.15 / 0.01 mg/cm2/kv/ step]

015

M (Max Correction)

*ENG

016

C (Max Correction)

*ENG

017

Y (Max Correction)

*ENG

018

K (Max Abs Hum)

*ENG

Adjusts the maximum humidity correction value for each color. These SPs are effective only when the setting of SP3-611-013 is set to "1".

[1 to 99 / 20 / 1 g/m3/step]

019

M (Max Abs Hum)

*ENG

020

C (Max Abs Hum)

*ENG

021

Y (Max Abs Hum)

*ENG

3612

[Vk Display]

Displays Vk for each color.

001

Bk

*ENG

[-300 to 300 / - / 1 V/step]

002

M

*ENG

003

C

*ENG

004

Y

*ENG

3621

[Development DC Control: Display]

Plain: High speed, Thick 1: Middle speed, Thick 2 & FINE: Low speed

Displays the development DC bias adjusted with the process control for each line speed and color.

001

Plain: Bk

*ENG

[0 to 700 / 550 / 1 -V/step]

002

Plain: M

*ENG

003

Plain: C

*ENG

004

Plain: Y

*ENG

005

Thick 1: Bk

*ENG

[0 to 700 / 550 / 1 -V/step]

006

Thick 1: M

*ENG

007

Thick 1: C

*ENG

008

Thick 1: Y

*ENG

009

Thick 2 & FINE: Bk

*ENG

[0 to 700 / 550 / 1 -V/step]

010

Thick 2 & FINE: M

*ENG

011

Thick 2 & FINE: C

*ENG

012

Thick 2 & FINE: Y

*ENG

3631

[Charge DC Control: Display]

Plain: High speed, Thick 1: Middle speed, Thick 2 & FINE: Low speed

Displays the charge DC voltage adjusted with the process control for each line speed and color.

001

Plain: Bk

*ENG

[0 to 2000 / 690 / 1 -V/step]

002

Plain: M

*ENG

003

Plain: C

*ENG

004

Plain: Y

*ENG

005

Thick 1 & FINE: Bk

*ENG

[0 to 2000 / 690 / 1 -V/step]

006

Thick 1 & FINE: M

*ENG

007

Thick 1 & FINE: C

*ENG

008

Thick 1& FINE: Y

*ENG

009

Thick 2 & FINE: Bk

*ENG

[0 to 2000 / 690 / 1 -V/step]

010

Thick 2 & FINE: M

*ENG

011

Thick 2 & FINE: C

*ENG

012

Thick 2 & FINE: Y

*ENG

3641

[Charge AC Control: Display]

Plain: High speed

Displays the charge AC voltage adjusted with the process control for each color.

001

Plain: Bk

*ENG

[0 to 3 / 1.75 / 0.01 kV/step]

002

Plain: M

*ENG

003

Plain: C

*ENG

004

Plain: Y

*ENG

3651

[LD Power Control: Display]

Plain: High speed, Thick 1: Middle speed, Thick 2 & FINE: Low speed

Displays the LD power adjusted for each environment.

001

Plain: Bk

*ENG

[0 to 200 / 100 / 1 %/step]

002

Plain: M

*ENG

003

Plain: C

*ENG

004

Plain: Y

*ENG

005

Thick 1: Bk

*ENG

[0 to 200 / 100 / 1 %/step]

006

Thick 1: M

*ENG

007

Thick 1: C

*ENG

008

Thick 1: Y

*ENG

009

Thick 2 & FINE: Bk

*ENG

[0 to 200 / 100 / 1 %/step]

010

Thick 2 & FINE: M

*ENG

011

Thick 2 & FINE: C

*ENG

012

Thick 2 & FINE: Y

*ENG

3710

[HST Concentration Control: Set]

TD Sensor: Toner Concentration Control Setting

Selects the toner concentration control method by HST memory, which is in the TD sensor.

001

Control Method: Selection

*ENG

[0 or 1 / 1 / - ] 0: Not Use, 1: Use

3711

[HST Concentration Control: Bk]

Displays the factory settings of the black PCDU.

001

Vcnt

*ENG

[0 to 5 / 4 / 0.1 V/step]

002

Vt

*ENG

[0 to 5 / 2.5 / 0.1 V/step]

003

Sensitivity: HL

*ENG

[1.22 to 3.77 / 2.1 / 0.01 V/step]

004

Sensitivity: HM

*ENG

[0 to 2.55 / 1.05 / 0.01 V/step]

005

Sensitivity: ML

*ENG

006

Set Detection

*ENG

[0 to 5 / 1 / 0.1 V/step]

007

Without Developer

*ENG

[0 to 5 / 1.2 / 0.1 V/step]

008

With Developer

*ENG

[0 to 5 / 1.3 / 0.1 V/step]

009

Serial Number 1

*ENG

[0 to 255 / - / 1 V/step]

010

Serial Number 2

*ENG

011

Adjustment: Vt

*ENG

[0 to 5 / 3 / 0.1 V/step]

012

Adjustment: Vtref

*ENG

[0 to 5 / 3 / 0.1 V/step]

013

Adjustment: Vtcnt

*ENG

[0 to 5 / 4 / 0.01 V/step]

014

Adjustment: Gamma

*ENG

[0 to 2.55 / 0 / 0.01 mg/cm2/kV /step]

015

Adjustment: Vcnt Result

*ENG

[0 to 9 / 9 / 1 /step]

3712

[HST Concentration Control: M]

Displays the factory settings of the magenta PCDU.

001

Vcnt

*ENG

[0 to 5 / 4 / 0.1 V/step]

002

Vt

*ENG

[0 to 5 / 2.5 / 0.1 V/step]

003

Sensitivity: HL

*ENG

[1.22 to 3.77 / 2.1 / 0.01 V/step]

004

Sensitivity: HM

*ENG

[0 to 2.55 / 1.05 / 0.01 V/step]

005

Sensitivity: ML

*ENG

006

Set Detection

*ENG

[0 to 5 / 1 / 0.1 V/step]

007

Without Developer

*ENG

[0 to 5 / 1.2 / 0.1 V/step]

008

With Developer

*ENG

[0 to 5 / 1.3 / 0.1 V/step]

009

Serial Number 1

*ENG

[0 to 255 / - / 1 V/step]

010

Serial Number 2

*ENG

011

Adjustment: Vt

*ENG

[0 to 5 / 3 / 0.1 V/step]

012

Adjustment: Vtref

*ENG

[0 to 5 / 3 / 0.1 V/step]

013

Adjustment: Vtcnt

*ENG

[0 to 5 / 4 / 0.01 V/step]

014

Adjustment: Gamma

*ENG

[0 to 2.55 / 0 / 0.01 mg/cm2/kV /step]

015

Adjustment: Vcnt Result

*ENG

[0 to 9 / 9 / 1 /step]

3713

[HST Concentration Control: C]

Displays the factory settings of the cyan PCDU.

001

Vcnt

*ENG

[0 to 5 / 4 / 0.1 V/step]

002

Vt

*ENG

[0 to 5 / 2.5 / 0.1 V/step]

003

Sensitivity: HL

*ENG

[1.22 to 3.77 / 2.1 / 0.01 V/step]

004

Sensitivity: HM

*ENG

[0 to 2.55 / 1.05 / 0.01 V/step]

005

Sensitivity: ML

*ENG

006

Set Detection

*ENG

[0 to 5 / 1 / 0.1 V/step]

007

Without Developer

*ENG

[0 to 5 / 1.2 / 0.1 V/step]

008

With Developer

*ENG

[0 to 5 / 1.3 / 0.1 V/step]

009

Serial Number 1

*ENG

[0 to 255 / - / 1 V/step]

010

Serial Number 2

*ENG

011

Adjustment: Vt

*ENG

[0 to 5 / 3 / 0.1 V/step]

012

Adjustment: Vtref

*ENG

[0 to 5 / 3 / 0.1 V/step]

013

Adjustment: Vtcnt

*ENG

[0 to 5 / 4 / 0.01 V/step]

014

Adjustment: Gamma

*ENG

[0 to 2.55 / 0 / 0.01 mg/cm2/kV /step]

015

Adjustment: Vcnt Result

*ENG

[0 to 9 / 9 / 1 /step]

3714

[HST Concentration Control: Y]

Displays the factory settings of the yellow PCDU.

001

Vcnt

*ENG

[0 to 5 / 4 / 0.1 V/step]

002

Vt

*ENG

[0 to 5 / 2.5 / 0.1 V/step]

003

Sensitivity: HL

*ENG

[1.22 to 3.77 / 2.1 / 0.01 V/step]

004

Sensitivity: HM

*ENG

[0 to 2.55 / 1.05 / 0.01 V/step]

005

Sensitivity: ML

*ENG

006

Set Detection

*ENG

[0 to 5 / 1 / 0.1 V/step]

007

Without Developer

*ENG

[0 to 5 / 1.2 / 0.1 V/step]

008

With Developer

*ENG

[0 to 5 / 1.3 / 0.1 V/step]

009

Serial Number 1

*ENG

[0 to 255 / - / 1 V/step]

010

Serial Number 2

*ENG

011

Adjustment: Vt

*ENG

[0 to 5 / 3 / 0.1 V/step]

012

Adjustment: Vtref

*ENG

[0 to 5 / 3 / 0.1 V/step]

013

Adjustment: Vtcnt

*ENG

[0 to 5 / 4 / 0.01 V/step]

014

Adjustment: Gamma

*ENG

[0 to 2.55 / 0 / 0.01 mg/cm2/kV /step]

015

Adjustment: Vcnt Result

*ENG

[0 to 9 / 9 / 1 /step]

3800

[Toner Collection Bottle Full Detection]

Displays/ adjusts the toner collection bottle detection settings. These SPs are used for NRS.

001

Condition

*CTL

[0 to 4 / 0 / 1 /step]

002

Detection Times

*CTL

[0 to 50 / - / 1 /step]

003

Print Page After Near Full

*CTL

[0 to 1000 / 0 / 1 sheet/step]

004

Pixel Count After Near Full

*CTL

[0 to 200000 / - / 1 cm2/step]

005

Pixel Count After Replacement

*CTL

Displays the pixel counter after replacement of toner collection bottle.

[0 to 200000 / - / 1 cm2/step]

008

Coefficient

*ENG

[0.5 to 1.5 / 1 / 0.1 /step]

011

Notice Setting

*ENG

Enables or disables the calling for @Remote.

[0 or 1 / 1 / - ]

0: Enable @Remote calling

1: Disable @Remote calling

NOTE:

If the toner collection bottle has been replaced before the machine detects used toner near full when this setting is set to "0", the machine cannot detect toner collection bottle near full. In that case, set SP3-902-017 to "1".

012

Day Threshold: Toner Collection bottle:NF

*ENG

[1 to 30 / 5 / 1 day/step]

Sets the threshold days for the near-full display. The near-full of the toner collection bottle is displayed after the toner collection full sensor has detected the actuator in the toner collection bottle.

013

Total:Toner Collection Bottle

*ENG

Displays the total amount of the used toner.

[0 to 999999999 / - / 1]

014

Mechanism Full Detection Date

*ENG

Displays the date of the full detection fot the toner collection bottle.

3900

[Waste Toner Full Detection]

Turns toner collection bottle full detection on or off.

001

ON/OFF Setting

*ENG

[0 or 1 / 1 / - ]

0: OFF, 1: ON

3901

[New PCU Detection]

Turns new PCDU detection on or off.

001

ON/OFF Setting

*ENG

[0 or 1 / 1 / - ]

0: OFF, 1: ON

3902

[Manual New Unit Set]

Turns the new unit detection flag for each PM unit on or off.
The use of these counters is explained in the PM section and in the relevant parts of section 3 (Replacement and Adjustment).

001

Development Unit: Bk

*ENG

[0 or 1 / 0 / - ]

0: OFF, 1: ON

002

Development Unit: Y

*ENG

003

Development Unit: C

*ENG

004

Development Unit: M

*ENG

005

Developer: Bk

*ENG

[0 or 1 / 0 / - ]

0: OFF, 1: ON

006

Developer: Y

*ENG

007

Developer: C

*ENG

008

Developer: M

*ENG

009

PCU (Drum Unit): Bk

*ENG

[0 or 1 / 0 / - ]

0: OFF, 1: ON

010

PCU (Drum Unit): Y

*ENG

011

PCU (Drum Unit): C

*ENG

012

PCU (Drum Unit): M

*ENG

013

Image Transfer Unit

*ENG

[0 or 1 / 0 / - ]

0: OFF, 1: ON

Do not use 3902-013 if you only change the cleaning unit.

3902-015: This is for the image transfer belt cleaning unit.

014

Fusing Unit

*ENG

015

Cleaning Unit

*ENG

016

Paper Transfer Unit

*ENG

017

Toner Collection Bottle

*ENG

018

Fusing Roller (Heating Roller)

*ENG

[0 or 1 / 0 / - ]

0: OFF, 1: ON

"Fusing Roller" is designated as "Heating Roller" in this manual.

019

Pressure Roller