7401 |
[Total SC Counter] |
||
Displays the number of SC codes detected. |
|||
001 |
SC Counter |
*CTL |
[0 to 9999 / 0 / 1/step ] |
7403 |
[SC History] |
||
Logs the SC codes detected. The 10 most recently detected SC Codes are not displayed on the screen, but can be seen on the SMC (logging) outputs. |
|||
001 |
Latest |
*CTL |
- |
002 |
Latest 1 |
||
003 |
Latest 2 |
||
004 |
Latest 3 |
||
005 |
Latest 4 |
||
006 |
Latest 5 |
||
007 |
Latest 6 |
||
008 |
Latest 7 |
||
009 |
Latest 8 |
||
010 |
Latest 9 |
7502 |
[Total Paper Jam Counter] |
||
Displays the total number of jams detected. |
|||
001 |
Total Jam |
* CTL |
[0 to 9999 / 0 / 1 sheet/step ] |
7503 |
[Total Original Jam Counter] |
||
Displays the total number of original jams. |
|||
001 |
Original Jam counter |
*CTL |
[0 to 9999 / 0 / 1 original/step ] |
7504 |
[Paper Jam Location] ON: On check, OFF: Off Check |
||
Displays the number of jams according to the location where jams were detected. NOTE: The LCT is counted as the 3rd feed station. |
|||
001 |
At Power On |
*CTL |
For details, ( |
003 |
Tray 1: ON |
*CTL |
|
004 |
Tray 2: ON |
*CTL |
|
005 |
Tray 3: ON |
*CTL |
|
006 |
Tray 4: ON |
*CTL |
|
007 |
LCT : ON |
*CTL |
|
008 |
Bypass: ON |
*CTL |
|
009 |
Duplex: ON |
*CTL |
|
011 |
Vertical Transport 1: ON |
*CTL |
|
012 |
Vertical Transport 2: ON |
*CTL |
|
013 |
Bank: Transport Sn1 |
*CTL |
For details, ( |
014 |
Bank: Transport Sn2 |
*CTL |
|
017 |
Registration: ON |
*CTL |
|
018 |
Fusing Entrance: ON |
*CTL |
|
019 |
Fusing Exit: ON |
*CTL |
|
020 |
Paper Exit: ON |
*CTL |
|
021 |
Bridge Exit: ON |
*CTL |
|
022 |
Bridge Transport: ON |
*CTL |
|
024 |
Junction Gate Sensor : On |
*CTL |
|
025 |
Duplex Exit: ON |
*CTL |
For details, ( |
026 |
Duplex Entrance: ON (Out) |
*CTL |
|
027 |
Duplex Entrance: ON (Out) |
*CTL |
|
051 |
Vertical Transport 1: Off |
*CTL |
|
052 |
Vertical Transport 2: Off |
*CTL |
|
053 |
Bank Transport 1: Off |
*CTL |
|
054 |
Bank Transport 2: Off |
*CTL |
|
057 |
Registration Sensor: Off |
*CTL |
|
058 |
LCT Feed Sensor : Off |
||
060 |
Paper Exit Off |
*CTL |
|
061 |
Bridge Exit: Off |
*CTL |
|
062 |
Bridge Transport: Off |
*CTL |
|
064 |
Junction Gate Sensor : Off |
*CTL |
For details, ( |
065 |
Duplex Exit: Off |
*CTL |
|
066 |
Duplex Entrance: Off (In) |
*CTL |
|
067 |
Duplex entrance : Off (Out) |
*CTL |
|
100 |
Finisher Entrance: KIN |
*CTL |
|
101 |
Finisher Shift Tray Exit: KIN |
*CTL |
|
102 |
Finisher Staple: KIN |
*CTL |
|
103 |
Finisher Exit: KIN |
*CTL |
|
105 |
Finisher Tray Lift Motor: KIN |
*CTL |
|
106 |
Finisher Jogger Motor: KIN |
*CTL |
|
107 |
Finisher Shift Motor: KIN |
*CTL |
|
108 |
Finisher Staple Motor: KIN |
*CTL |
|
109 |
Finisher Exit Motor: KIN |
*CTL |
|
191 |
Finisher Entrance: EUP |
*CTL |
For details, ( |
192 |
Finisher Proof Exit: EUP |
*CTL |
|
193 |
Finisher Shift Tray Exit: EUP |
*CTL |
|
194 |
Finisher Stapler Exit: EUP |
*CTL |
|
195 |
Finisher Exit: EUP |
*CTL |
|
198 |
Finisher Folder: EUP |
*CTL |
|
199 |
Finisher Tray Motor: EUP |
*CTL |
|
200 |
Finisher Jogger Motor: EUP |
*CTL |
|
201 |
Finisher Shift Motor: EUP |
*CTL |
|
202 |
Finisher Staple Moving Motor: EUP |
*CTL |
|
203 |
Finisher Staple Motor: EUP |
*CTL |
|
204 |
Finisher Folder Motor: EUP |
*CTL |
|
206 |
Finisher Punch Motor: EUP |
*CTL |
7505 |
[Original Jam Detection] |
||
Displays the total number of original jams by location. |
|||
001 |
At Power On |
*CTL |
- |
003 |
Skew Correction: On |
||
004 |
Registration Sensor: On |
||
005 |
Original Exit Sensor: On |
||
053 |
Skew Correction: Off |
||
054 |
Registration Sensor: Off |
||
055 |
Original Exit Sensor: Off |
7506 |
[Jam Count by Paper Size] |
||
Displays the number of jams according to the paper size. |
|||
005 |
A4 LEF |
*CTL |
[0 to 9999 / 0 / 1 sheet/step ] |
006 |
A5 LEF |
*CTL |
|
014 |
B5 LEF |
*CTL |
|
038 |
LT LEF |
*CTL |
|
044 |
HLT LEF |
*CTL |
|
132 |
A3 SEF |
*CTL |
[0 to 9999 / 0 / 1 sheet/step ] |
133 |
A4 SEF |
*CTL |
|
134 |
A5 SEF |
*CTL |
|
141 |
B4 SEF |
*CTL |
|
142 |
B5 SEF |
*CTL |
|
160 |
DLT SEF |
*CTL |
|
164 |
LG SEF |
*CTL |
|
166 |
LT SEF |
*CTL |
|
172 |
HLT SEF |
*CTL |
|
255 |
Others |
*CTL |
[0 to 9999 / 0 / 1 sheet/step ] |
7507 |
[Plotter Jam History] |
||
Displays the 10 most recently detected paper jams. |
|||
001 |
Latest |
*CTL |
- |
002 |
Latest 1 |
||
003 |
Latest 2 |
||
004 |
Latest 3 |
||
005 |
Latest 4 |
||
006 |
Latest 5 |
||
007 |
Latest 6 |
||
008 |
Latest 7 |
||
009 |
Latest 8 |
||
010 |
Latest 9 |
7508 |
[Original Jam History] |
||
Displays the 10 most recently detected original jams. |
|||
001 |
Latest |
*CTL |
- |
002 |
Latest-1 |
||
003 |
Latest-2 |
||
004 |
Latest-3 |
||
005 |
Latest-4 |
||
006 |
Latest-5 |
||
007 |
Latest-6 |
||
008 |
Latest-7 |
||
009 |
Latest-8 |
||
010 |
Latest-9 |
7624 |
Part Replacement Operation ON/OFF |
|
Selects the PM maintenance for each part. |
||
001 |
K Drum Unit |
[0 or 1 / 1 -] 0: Not PM maintenance 1: PM maintenance |
002 |
M Drum Unit |
|
003 |
C Drum Unit |
|
004 |
Y Drum Unit |
|
005 |
K Dev Unit |
|
006 |
M Dev Unit |
|
007 |
C Dev Unit |
|
008 |
Y Dev Unit |
|
009 |
K Developer |
|
010 |
M Developer |
|
011 |
C Developer |
|
012 |
Y Developer |
|
013 |
ITB Unit |
[0 or 1 / 1 -] 0: Not PM maintenance 1: PM maintenance |
014 |
Belt Cleaning Unit |
|
015 |
Fusing Unit |
|
016 |
PTR Unit |
|
017 |
Waste Toner Bottle |
|
018 |
Fusing Roller |
|
019 |
Pressure Roller |
7801 |
[ROM No/ Firmware Version] |
||
255 |
Engine |
*CTL |
Displays all versions and ROM numbers in the machine. |
7803 |
[PM Counter Display] (Page, Unit, [Color]) |
||||||
Displays the number of sheets printed for each current maintenance unit. PM counters click up based on the number of A4 (LT) LEF size sheets printed. Therefore, the A3 (DLT) Double Count is activated. The Double Count cannot be deactivated. When a unit is replaced, the machine automatically detects that the new unit is installed. Then, the current PM counter value is automatically moved to the PM Counter - Previous (SP7-906-1 to 10) and is reset to “0”. The total number of sheets printed with the last unit replaced can be checked with SP7-906-1 to 10. NOTE: The LCT is counted as the 3rd feed station. |
|||||||
001 |
Paper |
*CTL |
- |
||||
002 |
Page: K Drum Unit |
*ENG |
- |
||||
003 |
Page: M Drum Unit |
||||||
004 |
Page: C Drum Unit |
||||||
005 |
Page: Y Drum Unit |
||||||
006 |
Page: K Dev Unit |
||||||
007 |
Page: M Dev Unit |
||||||
008 |
Page: C Dev Unit |
||||||
009 |
Page: Y Dev Unit |
||||||
010 |
Page: K Developer |
*ENG |
- |
||||
011 |
Page: M Developer |
||||||
012 |
Page: C Developer |
||||||
013 |
Page: Y Developer |
||||||
014 |
Page: ITB Unit |
||||||
015 |
Page: Belt Cleaning Unit |
||||||
016 |
Page: Fusing Unit |
||||||
017 |
Page: PTR Unit |
||||||
018 |
Page: Toner Collection Bottle |
||||||
019 |
Page: Fusing Roller (Heating Roller) |
||||||
020 |
Page: Pressure Roller |
||||||
Displays the number of revolutions of motors or clutches for each current maintenance unit. [ 0 to 9999999 / 0 / 1 revolution/step ] When a unit is replaced, the machine automatically detects that the new unit is installed. Then, the current PM counter value is automatically moved to the PM Counter - Previous (SP7-906-11 to 20) and is reset to “0”. The total number of revolutions made with the last unit replaced can be checked with SP7-906-11 to 20. |
|||||||
031 |
Rotation: K Drum Unit |
*ENG |
[0 to 999999999 / - / 1 mm/step ] |
||||
032 |
Rotation: M Drum Unit |
||||||
033 |
Rotation: C Drum Unit |
||||||
034 |
Rotation: Y Drum Unit |
||||||
035 |
Rotation: K Dev Unit |
||||||
036 |
Rotation: M Dev Unit |
||||||
037 |
Rotation: C Dev Unit |
||||||
038 |
Rotation: Y Dev Unit |
||||||
039 |
Rotation: K Developer |
||||||
040 |
Rotation: M Developer |
||||||
041 |
Rotation: C Developer |
||||||
042 |
Rotation: Y Developer |
||||||
043 |
Rotation: ITB Unit |
*ENG |
[0 to 999999999 / - / 1 mm/step ] |
||||
044 |
Rotation: Cleaning Unit |
*ENG |
|||||
045 |
Rotation: Fusing Unit |
*ENG |
|||||
046 |
Rotation: PTR Unit |
*ENG |
|||||
047 |
Measurement: Toner Collection bottle |
*ENG |
|||||
048 |
Rotation: Fusing Roller (Heating Roller) |
*ENG |
|||||
049 |
Rotation: Pressure Roller |
*ENG |
|||||
Displays the value given by the following formula: (Current revolution Target revolution) 100. This shows how much of the unit’s expected lifetime has been used up. The Rotation% counter is based on rotations, not prints. If the number of rotations reaches the limit, the machine enters the end condition for that unit. If the print count lifetime is reached first, the machine also enters the end condition, even though the R% counter is still less than 100%. |
|||||||
061 |
Rotation (%): K Drum Unit |
*ENG |
[0 to 255 / - / 1 %/step] |
||||
062 |
Rotation (%): M Drum Unit |
||||||
063 |
Rotation (%): C Drum Unit |
||||||
064 |
Rotation (%): Y Drum Unit |
||||||
065 |
Rotation (%): K Dev Unit |
||||||
066 |
Rotation (%): M Dev Unit |
||||||
067 |
Rotation (%): C Dev Unit |
||||||
068 |
Rotation (%): Y Dev Unit |
||||||
069 |
Rotation (%): K Developer |
||||||
070 |
Rotation (%): M Developer |
||||||
071 |
Rotation (%): C Developer |
||||||
072 |
Rotation (%): Y Developer |
||||||
073 |
Rotation (%): ITB Unit |
*ENG |
[0 to 255 / - / 1 %/step] |
||||
074 |
Rotation (%): Cleaning Unit |
||||||
075 |
Rotation (%): Fusing Unit |
||||||
076 |
Rotation (%): PTR Unit |
||||||
077 |
Measurement (%): Toner Collection bottle |
||||||
078 |
Rotation (%): Fusing Roller (Heating Roller) |
||||||
079 |
Rotation (%): Pressure Roller |
||||||
Displays the value given by the following formula: (Current printouts Target printouts) 100. This shows how much of the unit’s expected lifetime has been used up. The Page% counter is based on printouts, not revolutions. If the number of printouts reaches the limit, the machine enters the end condition for that unit. If the revolution count lifetime is reached first, the machine also enters the end condition, even though the Page% counter is still less than 100%. |
|||||||
091 |
Page (%): K PCU (Drum Unit) |
*ENG |
[0 to 255 / - / 1 %/step] |
||||
092 |
Page (%): M PCU (Drum Unit) |
||||||
093 |
Page (%): C PCU (Drum Unit) |
||||||
094 |
Page (%): Y PCU (Drum Unit) |
||||||
095 |
Page (%): K Dev Unit |
||||||
096 |
Page (%): M Dev Unit |
||||||
097 |
Page (%): C Dev Unit |
||||||
098 |
Page (%): Y Dev Unit |
||||||
099 |
Page (%): K Developer |
*ENG |
[0 to 255 / - / 1 %/step] |
||||
100 |
Page (%): M Developer |
||||||
101 |
Page (%): C Developer |
||||||
102 |
Page (%): Y Developer |
||||||
103 |
Page (%): ITB Unit |
||||||
104 |
Page (%): Cleaning Unit |
||||||
105 |
Page (%): Fusing Unit |
||||||
106 |
Page (%): PTR Unit |
||||||
107 |
Page (%): Fusing Roller (Heating Roller) |
||||||
108 |
Page (%): Pressure Roller |
7804 |
[PM Counter Reset] PM Counter Clear (Unit, [Color]) |
||
Clears the PM counter. Press the Enter key after the machine asks “Execute?”, which will store the PM counter value in SP7-906 (PM Counter - Previous) and reset the value of the current PM counter (SP7-803) to “0”. |
|||
002 |
PCU (Drum Unit): Bk |
- |
- |
003 |
PCU (Drum Unit): M |
- |
- |
004 |
PCU (Drum Unit): C |
- |
- |
005 |
PCU (Drum Unit): Y |
- |
- |
006 |
PCU (Drum Unit): All |
- |
- |
007 |
Development Unit: Bk |
- |
- |
008 |
Development Unit: M |
- |
- |
009 |
Development Unit: C |
- |
- |
010 |
Development Unit: Y |
- |
- |
011 |
Development Unit: All |
- |
- |
012 |
Developer: Bk |
- |
- |
013 |
Developer: M |
- |
- |
014 |
Developer: C |
- |
- |
015 |
Developer: Y |
- |
- |
016 |
Developer: All |
- |
- |
017 |
ITB Unit |
- |
- |
018 |
Cleaning Unit |
- |
- |
019 |
Fusing Unit |
- |
- |
020 |
PTR Unit |
- |
- |
021 |
Toner Collection Bottle |
- |
- |
023 |
Fusing Roller(Heating Roller) |
- |
- |
024 |
Pressure Roller |
- |
- |
100 |
All |
- |
- |
7807 |
[SC/Jam Counter Reset] |
||
Clears the counters related to SC codes and paper jams. |
|||
001 |
SC/Jam Clear |
- |
- |
7832 |
[Self-Diagnose Result Display] |
||
Displays the result of the diagnostics. |
|||
001 |
Diag. Result |
*CTL |
- |
7835 |
[ACC Counter] |
||
001 |
Copy ACC |
*CTL |
Displays the ACC exectuion times for each mode. |
002 |
Printer ACC |
*CTL |
7836 |
Total Memory Size |
Displays the memory capacity of the controller system. |
7852 |
[DF Scan Glass Dust Check Counter] |
||
Counts the number of occurrences (0 to 65,535) when dust was detected on the scanning glass of the ADF or resets the dust detection counter. Counting is done only if SP4-020-1 (ADF Scan Glass Dust Check) is switched on. |
|||
001 |
Dust Detection Counter |
*CTL |
[0 to 9999 / - / 1 /step] |
002 |
Dust Detection Clear Counter |
*CTL |
[0 to 9999 / - / 1 /step] |
7853 |
[Replacement Counter] |
||
Displays the PM parts replacement number. |
|||
001 |
K Drum Unit |
*CTL |
[0 to 255 / - / 1 /step] |
002 |
M Drum Unit |
*CTL |
|
003 |
C Drum Unit |
*CTL |
|
004 |
Y Drum Unit |
*CTL |
|
005 |
K Dev Unit |
*CTL |
|
006 |
M Dev Unit |
*CTL |
|
007 |
C Dev Unit |
*CTL |
|
008 |
Y Dev Unit |
*CTL |
|
009 |
K Developer |
*CTL |
|
010 |
M Developer |
*CTL |
|
011 |
C Developer |
*CTL |
|
012 |
Y Developer |
*CTL |
|
013 |
ITB Unit |
*CTL |
[0 to 255 / - / 1 /step] |
014 |
Belt Cleaning Unit |
*CTL |
|
015 |
Fusing Unit |
*CTL |
|
016 |
PTR Unit |
*CTL |
|
017 |
Toner Collection Bottle |
*CTL |
|
018 |
Fusing Roller(Heating Roller) |
*CTL |
|
019 |
Pressure Roller |
*CTL |
7855 |
[Coverage Range] |
||
Sets the color coverage threshold. Coverage rate = Coverage per page / A4 full coverage (dots) x 100 There are three coverage counters: Color 1, Color 2, and Color 3
The total numbers of printouts (BW printing plus color printing) for each coverage range are displayed with the following SPs.
|
|||
001 |
Coverage Range 1 |
*CTL |
[1 to 200 / 5 /1] |
002 |
Coverage Range 2 |
*CTL |
[1 to 200 / 20 /1] |
7906 |
[Prev. Unit PM Counter] |
||||
(Page or Rotations, Unit, [Color]), Dev.: Development Unit |
|||||
Displays the number of sheets printed with the previous maintenance units. |
|||||
001 |
Page: K Drum Unit |
*ENG |
[0 to 9999999 / 0 / 1 page/step ] |
||
002 |
Page: M Drum Unit |
||||
003 |
Page: C Drum Unit |
||||
004 |
Page: Y Drum Unit |
||||
005 |
Page: K Dev Unit |
||||
006 |
Page: M Dev Unit |
||||
007 |
Page: C Dev Unit |
||||
008 |
Page: Y Dev Unit |
||||
009 |
Page: K Developer |
||||
010 |
Page: M Developer |
||||
011 |
Page: C Developer |
||||
012 |
Page: Y Developer |
||||
013 |
Page: ITB Unit |
*ENG |
[0 to 9999999 / 0 / 1 page/step ] |
||
014 |
Page: Cleaning Unit |
||||
015 |
Page: Fusing Unit |
||||
016 |
Page: PTR Unit |
||||
017 |
Page: Toner Collection Bottle |
||||
018 |
Fusing Roller (Heating Roller) |
||||
019 |
Pressure Roller |
||||
Displays the number of revolutions for motors or clutches in the previous maintenance units. |
|||||
031 |
Rotation: K Drum Unit |
*ENG |
[0 to 9999999 / 0 / 1 mm/step ] |
||
032 |
Rotation: M Drum Unit |
||||
033 |
Rotation: C Drum Unit |
||||
034 |
Rotation: Y Drum Unit |
||||
035 |
Rotation: K Dev Unit |
||||
036 |
Rotation: M Dev Unit |
||||
037 |
Rotation: C Dev Unit |
||||
038 |
Rotation: Y Dev Unit |
||||
039 |
Rotation: K Developer |
||||
040 |
Rotation: M Developer |
||||
041 |
Rotation: C Developer |
||||
042 |
Rotation: Y Developer |
||||
043 |
Rotation: ITB Unit |
*ENG |
[0 to 9999999 / 0 / 1 mm/step ] |
||
044 |
Rotation: Cleaning Unit |
||||
045 |
Rotation: Fusing Unit |
||||
046 |
Rotation: PTR Unit |
||||
047 |
Measurement: Toner Collection bottle |
||||
048 |
Rotation: Fusing Roller (Heating Roller) |
||||
049 |
Rotation: Pressure Roller |
||||
Displays the number of sheets printed with the previous maintenance unit or toner cartridge. |
|||||
061 |
Rotation (%): K Drum Unit |
*ENG |
[0 to 255 / 0 / 1 %/step ] |
||
062 |
Rotation (%): M Drum Unit |
||||
063 |
Rotation (%): C Drum Unit |
||||
064 |
Rotation (%): Y Drum Unit |
||||
065 |
Rotation (%): K Dev Unit |
||||
066 |
Rotation (%): M Dev Unit |
||||
067 |
Rotation (%): C Dev Unit |
||||
068 |
Rotation (%): Y Dev Unit |
||||
069 |
Rotation (%): K Developer |
*ENG |
[0 to 255 / 0 / 1 %/step ] |
||
070 |
Rotation (%): M Developer |
||||
071 |
Rotation (%): C Developer |
||||
072 |
Rotation (%): Y Developer |
||||
073 |
Rotation (%): ITB Unit |
||||
074 |
Rotation (%): Cleaning Unit |
||||
075 |
Rotation (%): Fusing Unit |
||||
076 |
Rotation (%): PTR Unit |
||||
077 |
Measurement (%): Toner Collection bottle |
||||
078 |
Rotation: Fusing Roller (Heating Roller) |
||||
079 |
Rotation: Pressure Roller |
||||
Displays the value given by the following formula: (Current count Yield count) x 100, where “Current count” is the current values in the counter for the part, and “Yield count” is the recommended yield. |
|||||
091 |
Page (%): K Drum Unit |
*ENG |
[0 to 255 / 0 / 1 %/step ] |
||
092 |
Page (%): M Drum Unit |
||||
093 |
Page (%): C Drum Unit |
||||
094 |
Page (%): Y Drum Unit |
||||
095 |
Page (%): K Dev Unit |
||||
096 |
Page (%): M Dev Unit |
||||
097 |
Page (%): C Dev Unit |
||||
098 |
Page (%): Y Dev Unit |
||||
099 |
Page (%): K Developer |
||||
100 |
Page (%): M Developer |
||||
101 |
Page (%): C Developer |
||||
102 |
Page (%): Y Developer |
||||
103 |
Page (%): ITB Unit |
*ENG |
[0 to 255 / 0 / 1 %/step ] |
||
104 |
Page (%): Cleaning Unit |
||||
105 |
Page (%): Fusing Unit |
||||
106 |
Page (%): PTR Unit |
||||
107 |
Page (%): Fusing Roller (Heating Roller) |
||||
108 |
Page (%): Pressure Roller |
7931 |
[Toner Bottle Bk] |
||
Displays the toner bottle information for Bk. |
|||
001 |
Machine Serial ID |
*ENG |
|
002 |
Cartridge Ver |
||
003 |
Brand ID |
||
004 |
Area ID |
||
005 |
Product ID |
||
006 |
Color ID |
||
007 |
Maintenance ID |
||
008 |
New Product Information |
||
009 |
Recycle Counter |
||
010 |
Date |
||
011 |
Serial No. |
||
012 |
Toner Remaining |
||
013 |
EDP Code |
||
014 |
End History |
||
015 |
Refill Information |
||
016 |
Attachment: Total Counter |
||
017 |
Attachment: Color Counter |
||
018 |
End: Total Counter |
||
019 |
End: Color Counter |
||
020 |
Attachment Date |
||
021 |
End Date |
7932 |
[Toner Bottle M] |
||
Displays the toner bottle information for M. |
|||
001 |
Machine Serial ID |
*ENG |
- |
002 |
Cartridge Ver |
||
003 |
Brand ID |
||
004 |
Area ID |
||
005 |
Product ID |
||
006 |
Color ID |
||
007 |
Maintenance ID |
||
008 |
New Product Information |
||
009 |
Recycle Counter |
||
010 |
Date |
||
011 |
Serial No. |
||
012 |
Toner Remaining |
*ENG |
- |
013 |
EDP Code |
||
014 |
End History |
||
015 |
Refill Information |
||
016 |
Attachment: Total Counter |
||
017 |
Attachment: Color Counter |
||
018 |
End: Total Counter |
||
019 |
End: Color Counter |
||
020 |
Attachment Date |
||
021 |
End Date |
7933 |
[Toner Bottle C] |
||
Displays the toner bottle information for C. |
|||
001 |
Machine Serial ID |
*ENG |
- |
002 |
Cartridge Ver |
||
003 |
Brand ID |
||
004 |
Area ID |
||
005 |
Product ID |
||
006 |
Color ID |
||
007 |
Maintenance ID |
||
008 |
New Product Information |
||
009 |
Recycle Counter |
||
010 |
Date |
||
011 |
Serial No. |
||
012 |
Toner Remaining |
*ENG |
- |
013 |
EDP Code |
||
014 |
End History |
||
015 |
Refill Information |
||
016 |
Attachment: Total Counter |
||
017 |
Attachment: Color Counter |
||
018 |
End: Total Counter |
||
019 |
End: Color Counter |
||
020 |
Attachment Date |
||
021 |
End Date |
7934 |
[Toner Bottle Y] |
||
Displays the toner bottle information for Y. |
|||
001 |
Machine Serial ID |
*ENG |
- |
002 |
Cartridge Ver |
||
003 |
Brand ID |
||
004 |
Area ID |
||
005 |
Product ID |
||
006 |
Color ID |
||
007 |
Maintenance ID |
||
008 |
New Product Information |
||
009 |
Recycle Counter |
||
010 |
Date |
||
011 |
Serial No. |
||
012 |
Toner Remaining |
*ENG |
- |
013 |
EDP Code |
||
014 |
End History |
||
015 |
Refill Information |
||
016 |
Attachment: Total Counter |
||
017 |
Attachment: Color Counter |
||
018 |
End: Total Counter |
||
019 |
End: Color Counter |
||
020 |
Attachment Date |
||
021 |
End Date |
7935 |
[Toner Bottle Log 1: Bk] |
||
001 |
Serial No. |
*ENG |
Displays the toner bottle information log 1 for Bk. |
002 |
Attachment Date |
||
003 |
Attachment: Total Counter |
||
004 |
Refill Information |
||
011 |
Serial No. |
*ENG |
Displays the toner bottle information log 2 for Bk. |
012 |
Attachment Date |
||
013 |
Attachment: Total Counter |
||
014 |
Refill Information |
||
021 |
Serial No. |
*ENG |
Displays the toner bottle information log 3 for Bk. |
022 |
Attachment Date |
||
023 |
Attachment: Total Counter |
||
024 |
Refill Information |
||
031 |
Serial No. |
*ENG |
Displays the toner bottle information log 4 for Bk. |
032 |
Attachment Date |
||
033 |
Attachment: Total Counter |
||
034 |
Refill Information |
||
041 |
Serial No. |
*ENG |
Displays the toner bottle information log 5 for Bk. |
042 |
Attachment Date |
||
043 |
Attachment: Total Counter |
||
044 |
Refill Information |
7936 |
[Toner Bottle Log 1: M] |
||
001 |
Serial No. |
*ENG |
Displays the toner bottle information log 1 for M. |
002 |
Attachment Date |
||
003 |
Attachment: Total Counter |
||
004 |
Refill Information |
||
011 |
Serial No. |
*ENG |
Displays the toner bottle information log 2 for M. |
012 |
Attachment Date |
||
013 |
Attachment: Total Counter |
||
014 |
Refill Information |
||
021 |
Serial No. |
*ENG |
Displays the toner bottle information log 3 for M. |
022 |
Attachment Date |
||
023 |
Attachment: Total Counter |
||
024 |
Refill Information |
||
031 |
Serial No. |
*ENG |
Displays the toner bottle information log 4 for M. |
032 |
Attachment Date |
||
033 |
Attachment: Total Counter |
||
034 |
Refill Information |
||
041 |
Serial No. |
*ENG |
Displays the toner bottle information log 5 for M. |
042 |
Attachment Date |
||
043 |
Attachment: Total Counter |
||
044 |
Refill Information |
7937 |
[Toner Bottle Log 1: C] |
||
001 |
Serial No. |
*ENG |
Displays the toner bottle information log 1 for C. |
002 |
Attachment Date |
||
003 |
Attachment: Total Counter |
||
004 |
Refill Information |
||
011 |
Serial No. |
*ENG |
Displays the toner bottle information log 2 for C. |
012 |
Attachment Date |
||
013 |
Attachment: Total Counter |
||
014 |
Refill Information |
||
021 |
Serial No. |
*ENG |
Displays the toner bottle information log 3 for C. |
022 |
Attachment Date |
||
023 |
Attachment: Total Counter |
||
024 |
Refill Information |
||
031 |
Serial No. |
*ENG |
Displays the toner bottle information log 4 for C. |
032 |
Attachment Date |
||
033 |
Attachment: Total Counter |
||
034 |
Refill Information |
||
041 |
Serial No. |
*ENG |
Displays the toner bottle information log 5 for C. |
042 |
Attachment Date |
||
043 |
Attachment: Total Counter |
||
044 |
Refill Information |
7938 |
[Toner Bottle Log 1: Y] |
||
001 |
Serial No. |
*ENG |
Displays the toner bottle information log 1 for Y. |
002 |
Attachment Date |
||
003 |
Attachment: Total Counter |
||
004 |
Refill Information |
||
011 |
Serial No. |
*ENG |
Displays the toner bottle information log 2 for Y. |
012 |
Attachment Date |
||
013 |
Attachment: Total Counter |
||
014 |
Refill Information |
||
021 |
Serial No. |
*ENG |
Displays the toner bottle information log 3 for Y. |
022 |
Attachment Date |
||
023 |
Attachment: Total Counter |
||
024 |
Refill Information |
||
031 |
Serial No. |
*ENG |
Displays the toner bottle information log 4 for Y. |
032 |
Attachment Date |
||
033 |
Attachment: Total Counter |
||
034 |
Refill Information |
||
041 |
Serial No. |
*ENG |
Displays the toner bottle information log 5 for Y. |
042 |
Attachment Date |
||
043 |
Attachment: Total Counter |
||
044 |
Refill Information |
7950 |
[Unit Replacement Date] |
||
Displays the replacement date of each PM unit. |
|||
001 |
Image Transfer Belt |
*ENG |
- |
002 |
Cleaning Unit |
||
003 |
Paper Transfer Unit |
||
004 |
Fusing Unit |
||
005 |
Toner Collection Bottle |
||
006 |
K PCU (Drum Unit) |
||
007 |
M PCU (Drum Unit) |
||
008 |
C PCU (Drum Unit) |
||
009 |
Y PCU (Drum Unit) |
||
010 |
Fusing Roller (Heating Roller) |
||
011 |
Pressure Roller |
7951 |
[Remaining Day Counter] |
||
Displays the remaining unit life of each PM unit. |
|||
001 |
Page: K Drum Unit |
*ENG |
[0 to 255 / 255 / 1 day/step] |
002 |
Page: M Drum Unit |
||
003 |
Page: C Drum Unit |
||
004 |
Page: Y Drum Unit |
||
005 |
Page: K Dev Unit |
||
006 |
Page: M Dev Unit |
||
007 |
Page: C Dev Unit |
||
008 |
Page: Y Dev Unit |
||
009 |
Page: K Developer |
||
010 |
Page: M Developer |
||
011 |
Page: C Developer |
||
012 |
Page: Y Developer |
||
013 |
Page: ITB Unit |
*ENG |
[0 to 255 / 255 / 1 day/step] |
014 |
Page: Cleaning Unit |
||
015 |
Page: Fusing Unit |
||
016 |
Page: PTR Unit |
||
017 |
Page: Fusing Roller (Heating Roller) |
||
018 |
Page: Pressure Roller |
||
031 |
Rotation: K Drum Unit |
*ENG |
[0 to 255 / 255 / 1 day/step] |
032 |
Rotation: M Drum Unit |
||
033 |
Rotation: C Drum Unit |
||
034 |
Rotation: Y Drum Unit |
||
035 |
Rotation: K Dev Unit |
||
036 |
Rotation: M Dev Unit |
||
037 |
Rotation: C Dev Unit |
||
038 |
Rotation: Y Dev Unit |
||
039 |
Rotation: K Developer |
||
040 |
Rotation: M Developer |
||
041 |
Rotation: C Developer |
||
042 |
Rotation: Y Developer |
||
043 |
Rotation: ITB Unit |
*ENG |
[0 to 255 / 255 / 1 day/step] |
044 |
Rotation: Cleaning Unit |
||
045 |
Rotation: Fusing Unit |
||
046 |
Rotation: PTR Unit |
||
047 |
Measurement: Toner Collection bottle |
||
048 |
Rotation: Fusing Roller (Heating Roller) |
||
049 |
Rotation: Pressure Roller |
7952 |
[PM Yield Setting] |
||
Adjusts the unit yield of each PM unit. |
|||
001 |
Rotation: ITB Unit |
*CTL |
[0 to 999999999 / 256597000 / 1 mm/step] |
002 |
Rotation: Cleaning Unit |
*CTL |
[0 to 999999999 / 128299000 / 1 mm/step] |
003 |
Rotation: Fusing Unit |
*CTL |
[0 to 999999999 / 155595000 / 1 mm/step] |
004 |
Rotation: Paper Transfer Unit |
*CTL |
[0 to 999999999 / 192448000/ 1 mm/step] |
011 |
Page: ITB Unit |
*CTL |
[0 to 999999 / 320000 / 1 sheet/step] |
012 |
Page: Cleaning Unit |
*CTL |
[0 to 999999 / 160000 / 1 sheet/step] |
013 |
Page: Fusing Unit |
*CTL |
[0 to 999999 / 160000 / 1 sheet/step] |
014 |
Page: Paper Transfer Unit |
*CTL |
[0 to 999999 / 240000/ 1 sheet/step] |
021 |
Day: K Drum Unit |
*CTL |
Adjusts the threshold day for the near end fro each PM unit. [1 to 30 / 15 / 1 day/step] These threshold days are used for @Remote alarms. |
022 |
Day: M Drum Unit |
||
023 |
Day: C Drum Unit |
||
024 |
Day: Y Drum Unit |
||
025 |
Day: K Dev Unit |
||
026 |
Day: M Dev Unit |
||
027 |
Day: C Dev Unit |
||
028 |
Day: Y Dev Unit |
||
029 |
Day: K Developer |
||
030 |
Day: M Developer |
||
031 |
Day: C Developer |
||
032 |
Day: Y Developer |
||
033 |
Day: ITB Unit |
*CTL |
Adjusts the threshold day for the near end fro each PM unit. [1 to 30 / 15 / 1 day/step] These threshold days are used for @Remote alarms. |
034 |
Day:Cleaning Unit |
||
035 |
Day: Fusing Unit |
||
036 |
Day: PTR Unit |
||
037 |
Day: Toner Collection Botte |
||
038 |
Rotation: PCU (Drum Unit): Bk |
*CTL |
[0 to 999999999 / 0 / 1 mm/step] |
039 |
Rotation: PCU (Drum Unit): M |
||
040 |
Rotation: PCU (Drum Unit): C |
||
041 |
Rotation: PCU (Drum Unit): Y |
||
042 |
Rotation: Development Unit: Bk |
*CTL |
[0 to 999999999 / 0 / 1 mm/step] |
043 |
Rotation: Development Unit: M |
||
044 |
Rotation: Development Unit: C |
||
045 |
Rotation: Development Unit: Y |
||
046 |
Rotation: Developer: Bk |
*CTL |
[0 to 999999999 / 0 / 1 mm/step] |
047 |
Rotation: Developer: M |
||
048 |
Rotation: Developer: C |
||
049 |
Rotation: Developer: Y |
||
050 |
Page: PCU (Drum Unit): Bk |
*CTL |
[0 to 999999 / 0 / 1 sheet/step] |
051 |
Page: PCU (Drum Unit): M |
||
052 |
Page: PCU (Drum Unit): C |
||
053 |
Page: PCU (Drum Unit): Y |
||
054 |
Page: Development Unit: Bk |
*CTL |
[0 to 999999 / 0 / 1 sheet/step] |
055 |
Page: Development Unit: M |
||
056 |
Page: Development Unit: C |
||
057 |
Page: Development Unit: Y |
||
058 |
Page: Developer: Bk |
*CTL |
[0 to 999999 / 0 / 1 sheet/step] |
059 |
Page: Developer: M |
||
060 |
Page: Developer: C |
||
061 |
Page: Developer: Y |
7953 |
[Operation Env. Log: PCU: Bk] |
||
Displays the PCDU rotation distance in each specified operation environment. T: Temperature (C), H: Relative Humidity (%) |
|||
001 |
T<=0 |
*CTL |
[0 to 99999999 / - / 1 mm/step] |
002 |
0<T<=5:0<=H<30 |
||
003 |
0<T<=5: 30<=H<70 |
||
004 |
0<T<=5: 70<=H<=100 |
||
005 |
5<T<15: 0<=H<30 |
||
006 |
5<T<15: 30<=H<55 |
||
007 |
5<T<15: 55<=H<80 |
||
008 |
5<T<15: 80<=H<=100 |
||
009 |
15<=T<25: 0<=H<30 |
||
010 |
15<=T<25: 30<=H<55 |
||
011 |
15<=T<25: 55<=H<80 |
*CTL |
[0 to 99999999 / - / 1 mm/step] |
012 |
15<=T<25: 80<=H<=100 |
||
013 |
25<=T<30: 0<=H<30 |
||
014 |
25<=T<30: 55<=H<55 |
||
015 |
25<=T<30: 55<=H<80 |
||
016 |
25<=T<30: 80<=H<=100 |
||
017 |
30<=T: 0<=H<30 |
||
018 |
30<=T: 30<=H<55 |
||
019 |
30<=T: 55<=H<80 |
||
020 |
30<=T: 80<=H<=100 |
7954 |
[Operation Env. Log Clear] |
||
Clears the operation environment log. |
|||
001 |
- |
7955 |
Fusing Stop |
||
001 |
Near End: Page |
- |
[1 to 999999 / 318000 / 1 sheet/step] |
Displays the threshold sheet for the heating roller near end. |
|||
002 |
End: Page |
- |
[1 to 999999 / 330000 / 1 sheet/step] |
Displays the threshold sheet for the heating roller end. |
|||
003 |
Near End: Rotation |
- |
[0 to 999999999 / 999999999 / 1 mm/step] |
Displays the threshold distance for the heating roller near end. |
|||
004 |
End: Rotation |
- |
[0 to 999999999 / 999999999 / 1 mm/step] |
Displays the threshold distance for the heating roller end. |