Top Page > Main Chapters > Troubleshooting > Process Control Error Conditions > Process Control Self-Check Result > Vsg Adjustment Result
Vsg Adjustment Result
SP3-325-001 to -010 (Vsg Adjustment Result)
No. |
Result |
Description |
Possible Causes/Action |
1 |
O.K |
Vsg adjustment is correctly done. |
- |
2 |
ID sensor adjustment error |
Vsg cannot be adjusted within 4.0 ±0.5V. |
Dirty ID sensor (toner, dust, or foreign material)
Dirty transfer belt
Scratched image transfer belt
Defective ID sensor
Poor connection
Defective IOB
Clean the ID sensor.
Check the belt cleaning. Clean or replace the transfer belt.
Replace the image transfer belt.
Replace the ID sensor.
Check the connection.
Replace the IOB board.
|
3 |
ID sensor output error |
ID sensor output is more than "Voffset Threshold" (SP3-324-004) |
Defective ID sensor
Poor connection
Defective IOB
Replace the ID sensor.
Check the connection.
Replace the IOB board.
|
9 |
Vsg Adjustment error |
Vsg adjustment has not been completed. |
Retry SP3-321-010. |