Fuse |
Rating |
Symptom when turning on the main switch |
|
---|---|---|---|
115V |
220V - 240V |
||
FU1 |
15A/125V |
8A/250V |
No response. (5V power to the PSU is not supplied.) |
FU2 |
10A/125V |
6.3A/250V |
No response. (5V power to the BICU and controller is not supplied.) |
FU3 |
2A/250V |
1A/250V |
5V power to the scanner heater and tray heater is not supplied. |
FU4 |
1A/250V |
1A/250V |
5V power to the SIO and heater is not supplied. |
FU5 |
5A/250V |
5A/250V |
5V power to the IOB not supplied. |
FU6 |
2A/250V |
2A/125V |
5VS power to the BICU not supplied. |
FU7 |
10A/125V |
10A/125V |
24VS power to the IOB not supplied. |
FU8 |
10A/125V |
10A/125V |
24VS power to the IOB not supplied. |
FU9 |
6.3A/125V |
6.3A/125V |
24V power to the IOB not supplied. |
FU10 |
6.3A/125V |
6.3A/125V |
24V power to the SIO not supplied. |
FU11 |
6.3A/125V |
6.3A/125V |
24V power to the BICU and MB not supplied. |
FU12 |
6.3A/125V |
6.3A/125V |
24V power to the PFU or LCT not supplied. |
FU13 |
6.3A/125V |
6.3A/125V |
24V power to the finisher not supplied. |
FU14 |
5A/250V |
5A/250V |
5V power to the BICU not supplied. |