Output the SBU test pattern with SP4-807-001 to make sure the scanner SBU control operates correctly. The SBU test pattern prints out after you have set the SP mode settings and pressed the start key.
The CCD on the SBU board may be defective if the copy is abnormal and the SBU test pattern is normal.
The followings can be the cause if the copy is normal and the SBU test pattern is abnormal:
The harness may not be correctly connected between the SBU and the BICU.
The BICU or SBU board may be defective.