Skip header
 

Energy Save Effectiveness

SP 8941 (Machine Status) keeps a record of the amount of time that the machine spends in each mode.

With this data, and the power consumption values from the specifications, we can estimate the amount of energy that is used by the machine.

This should only be used as a reference value, because the power consumption specifications are measured in a controlled environment with a constant power supply.

To get an exact measurement at the customers site, a watt meter must be used to measure the actual energy consumed.

To use SP8941 to calculate the energy consumed:

Here is an example calculation.

Machine

Condition

SP8941:

Machine Status

Time at Start (min.)

_01.png

Time at End (min.)

_02.png

Running time (hour)

(_02.png-_01.png)/60 = _03.png

Power consumption Spec. (W)

_04.png

Power consumption (KWH)

(_03.pngx_04.png)/1000 = _05.png

Operating

001: Operating Time

21089.0

21386.0

5.0

1081.8

5.35

_02.png

Stand by

(Ready)

002: Standby Time

306163.0

308046.0

31.4

214.0

6.72

_03.png

Energy save (Panel off)

003: Energy Save Time

71386.0

75111.0

62.1

214.0

13.29

_04.png

Low power

004: Low Power Time

154084.0

156340.0

37.6

146.0

5.49

_05.png

Off/Sleep

005: Off Mode Time

508776.0

520377.0

193.4

7.0

1.35

Total _06.png

32.20