Skip header
 

Installing the DF Handle

b862i509.jpg

  1. Attach the holder [A] to the scanner right cover (Tapping Screw - M3x12: x 2).

    • At first, secure the screw at the rear side (away from the operation panel) temporarily and then at the front side temporarily. After that, secure them fully.

    b862i513.jpg

  2. Install the bushing: 6MM [B] in the inside of the handle unit.

  3. Attach the handle unit to the stud bracket on the left side of the ADF.

    b862i510.jpg

  4. In the outside of the handle unit, install the bushing - M6 [C] first, and then the spacer [D].

    b862i514.jpg

  5. Secure the handle unit with a screw ( x 1: M3x8).

    b862i511.jpg

  6. Clean the handle unit with alcohol. Then attach the stud decal [E] at the location that was cleaned.

    b862i503.jpg

  7. Attach the handle bracket [F] at the front right side on the bottom of the ADF unit (Tapping Screw [Self Binding] x 2: M3x12).

  8. Close the ADF unit.

    b862i504.jpg

  9. Attach the hinge stoppers (left [G] and right [H]) to the left and right hinges (Tapping screw x 2: M4x8 each).

    b862i505.jpg

  10. Clean the front side of the duplex unit with alcohol. Then attach the operation decal [I] at the location that was cleaned.

    b862i506.jpg

  11. Check the operation of the handle unit [J].