A: Leading edge registration
Use A3/DLT paper to make a temporary test chart as shown above.
Put the temporary test chart on the ARDF. Then make a copy from one of the feed stations.
Check the registration. Check the leading edge and side-to-side registration. Adjust the following SP modes if necessary.
Standard: 4.2 ± 2 mm for the leading edge registration, 2 ± 1 mm for the side-to-side registration. Use the following SP modes to adjust if necessary.
SP Code |
What It Does |
Adjustment Range |
---|---|---|
SP6-006-001 |
Side-to-Side Regist: Front |
± 3.0 mm |
SP6-006-003 |
Leading Edge Registration |
± 5.0 mm |
SP6-006-005 |
Buckle: Duplex Front |
± 3.0 mm |
SP6-006-006 |
Buckle: Duplex Rear |
± 2.5 mm |
SP6-006-007 |
Rear Edge Erase (Trailing Edge) |
± 10.0 mm |