Skip header
 

Image Transfer Belt Cleaning Unit

  1. If you will install a new belt cleaning unit, then set SP 3902-015 to 1.

    Note

    • If you do this, then the machine will reset the PM counter for the belt cleaning unit automatically, after you turn the power on again.

    • Do not use SP3902-015 or 013 if you replace the complete ITB unit.

  2. Turn off the main power switch.

  3. Open the right door.

  4. Open the front door.

  5. Open the drum positioning plate. (_point.png PCDU)

    b222r541.png

  6. Loosen the screw [A].

  7. Turn the lock lever [B] clockwise

  8. Pull out the image transfer belt cleaning unit [C].