Adjustment after replacing the gear unit

Do the following procedures after replacing the gear unit.

  1. Turn on the main power switch.

  2. Enter "System SP" in the SP mode.

  3. Do “Amplitude Control" with SP1-902-001.

  4. Check the result of the Amplitude Control with SP1-902-002.

    0: Success, 2: Failure due to no sampling data,

    3: Failure due to insufficient number of pattern detections

    When the result of this adjustment is "2" or "3":

    • Check that all the PCUs are correctly set and that the image transfer belt unit is correctly set.

    • Do "Amplitude Control " again after checking the PCUs and image transfer belt unit.

    When the result is still "2" or "3" after checking the PCUs and image transfer belt unit:

    • Check that the gear unit is installed correctly.

  5. Exit the SP mode.