No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
816 |
CTL D |
Energy saving I/O sub-system error |
The energy saving I/O sub-system detects an error. |
||
|
||
Replace the controller board. |
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
||
---|---|---|---|---|
819 |
CTL C |
Fatal kernel error |
||
Due to a control error, a RAM overflow occurred during system processing. One of the following messages was displayed on the operation panel. |
||||
[0x5032] |
HAIC-P2 error |
Replace controller firmware |
||
[0x5245] |
vm_pageout: VM is full |
|||
[0x5355] |
L2 status time out |
|||
[554C] |
USB error |
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
820 |
CTL D |
Self-diagnostics error: CPU [XXXX]: Detailed error code |
[0612] |
Cut-in in ASIC occurs. |
|
|
||
Replace the controller board. |
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
833 |
CTL C |
Self-diagnostic error 8: Engine I/F ASIC |
[0F30] [0F31] |
|
|
Replace the BICU. |
||
[0F41] |
|
|
Replace the BICU |
||
[50B1] |
Could not initialize or read the bus connection. |
|
|
||
Replace the mother board |
||
[50B2] |
Value of the SSCG register is incorrect. |
|
|
||
Replace the mother board |
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
851 |
CTL B |
IEEE1394 interface error |
The 1394 interface is unusable. |
||
|
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
853 |
CTL B |
Wireless LAN card not detected |
The wireless LAN card is not detected before communication is established, though the wireless LAN board is detected. |
||
|
||
Check the connection. |
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
854 |
CTL B |
Wireless LAN/Bluetooth card not detected |
The wireless LAN/Bluetooth card is not detected after communication is established, but the wireless LAN board is detected. |
||
|
||
Check the connection. |
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
855 856 |
CTL B |
Wireless LAN/Bluetooth card error |
An error is detected in the wireless LAN/Bluetooth card. |
||
|
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
857 |
CTL B |
USB interface error |
The USB interface cannot be used due to a driver error. |
||
|
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
|
---|---|---|---|
858 |
CTL C |
HDD Encryption unit error 1 |
|
A serious error occurs when data is encrypted to update an encryption key with the HDD encryption unit. |
|||
[0] |
Encryption key acquisition error: The controller fails to get a new encryption key. |
||
|
|||
[1] |
Encryption key setting for HDD error: The controller fails to copy a new encryption key to the HDD. |
||
|
|||
[2] |
NVRAM data encryption error 1: An error occurs while the NVRAM data is encrypted. |
||
|
|||
[30] |
NVRAM data encryption error 2: An error occurs before the NVRAM data is encrypted. |
||
|
|||
[31] |
Other error: A serious error occurs while the data is encrypted. |
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
|
---|---|---|---|
859 |
CTL C |
HDD Encryption unit error 2 |
|
A serious error occurs when the HDD data is encrypted to update an encryption key with the HDD encryption unit. |
|||
[8] |
HDD check error: The HDD is not correctly installed. |
||
|
|||
[9] |
Power failure during the data encryption: The data encryption (NVRAM and HDD) has not been completed. |
||
|
|||
[10] |
Data read/write error: The DMAC error is detected twice or more. |
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
860 |
CTL B |
HDD: Initialization error |
The controller detects that the hard disk fails. |
||
|
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
861 |
CTL D |
HDD: Reboot error |
The HDD does not become ready within 30 seconds after the power is supplied to the HDD. |
||
|
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
863 |
CTL D |
HDD: Read error |
The data stored in the HDD cannot be read correctly. |
||
|
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
864 |
CTL D |
HDD: CRC error |
While reading data from the HDD or storing data in the HDD, data transmission fails. |
||
|
||
Replace the HDD. |
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
865 |
CTL D |
HDD: Access error |
An error is detected while operating the HDD. |
||
|
||
Replace the HDD. |
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
866 |
CTL B |
SD card authentication error |
A correct license is not found in the SD card. |
||
|
||
Store correct data in the SD card. |
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
867 |
CTL D |
SD card error |
The SD card is ejected from the slot. |
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
868 |
CTL D |
SD card access error
|
An error report is sent from the SD card reader.
|
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
870 |
CTL B |
Address book error |
An error is detected in the data copied to the address book over a network. |
||
|
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
872 |
CTL B |
HDD mail data error |
An error is detected in the HDD at machine initialization. |
||
|
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
873 |
CTL B |
HDD mail transfer error |
An error is detected in the HDD at machine initialization. |
||
|
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
874 |
CTL D |
Delete All error 1: HDD |
An error is detected while all of the HDD or NVRAM are formatted physically by the Data Overwrite Security Unit (D377). |
||
|
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
875 |
CTL D |
Delete All error 2: Data area |
An error is detected while all of the HDD or NVRAM are formatted logically by the Data Overwrite Security Unit (D377). |
||
|
||
Turn the main switch off/on and try the operation again |
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
876 |
CTL D |
Log Data Error |
An error was detected in the handling of the log data at power on or during machine operation. This can be caused by switching the machine off while it is operating. |
||
-001 |
Log Data Error 1 |
|
|
||
Initialize the HDD with SP5832-004. |
||
-002 |
Log Data Error 2 |
|
|
||
|
||
-003 |
Log Data Error 3 |
|
|
||
|
||
-004 |
Log Data Error 4 |
|
|
||
Initialize the HDD with SP5832-004. |
||
-005 |
Log Data Error 5 |
|
|
||
|
||
-099 |
Log Data Error 99 |
|
|
||
Ask your supervisor. |
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
877 |
CTL D |
HDD Data Overwrite Security SD card error |
The 'all delete' function cannot be executed but the Data Overwrite Security Unit (D377) is installed and activated. |
||
|
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
|
---|---|---|---|
878 |
CTL D |
TPM system authentication error |
|
The system firmware is not authenticated by TPM (security chip). |
|||
Replace the controller board. |
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
880 |
CTL D |
File format converter error |
The file format converter does not respond. |
||
|
||
Replace the file format converter. |