No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
900 |
CTL D |
Electric counter error |
Abnormal data in the counters. |
||
|
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
910 |
CTL D |
External Controller Error 1 |
911 |
External Controller Error 2 |
|
912 |
External Controller Error 3 |
|
913 |
External Controller Error 4 |
|
914 |
External Controller Error 5 |
|
- |
- |
The external controller alerted the machine about an error. |
- |
- |
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
919 |
CTL D |
External Controller Error 6 |
While EAC (External Application Converter), the conversion module, was operating normally, the receipt of a power line interrupt signal from the FLUTE serial driver was detected, or BREAK signal from the other station was detected. |
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
920 |
CTL D |
Printer application error |
An error is detected in the printer application program. |
||
|
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
921 |
CTL D |
Printer font error |
A necessary font is not found in the SD card. |
||
|
||
Check that the SD card has the correct data. |
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
990 |
CTL D |
Software performance error |
The software makes an unexpected operation. |
||
|
||
|
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
991 |
CTL C |
Software continuity error |
The software has attempted to perform an unexpected operation. However, unlike SC 990, the object of the error is continuity of the software. |
||
|
||
This SC is not displayed on the LCD (logging only). |
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
992 |
CTL D |
Undefined error |
Defective software program |
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
994 |
CTL C |
Operation panel management records exceeded |
An error occurred because the number of records exceeded the limit for images managed in the service layer of the firmware. This can occur if there if there are too many application screens open on the operation panel. |
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
995 |
D |
CPM setting error |
-001 |
|
|
|
||
-002 |
|
|
|
||
-003 |
|
|
|
||
-004 |
|
|
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
997 |
CTL B |
Application function selection error
|
|
||
|
No. |
Type |
Details (Symptom, Possible Cause, Troubleshooting Procedures) |
---|---|---|
998 |
CTL D |
Application start error |
No applications start within 60 seconds after the power is turned on. |
||
|
||
|
Note 1
If a problem always occurs in a specific condition (for example. printer driver setting, image file), the problem may be caused by a software error. In this case, the following data and information needs to be sent back to your product specialist. Please understand that it may take some time to get a reply on how to solve the problem, because in some cases the design staff in Japan must analyze the data.
Symptom / Possible Causes / Action taken
Summary sheet (SP mode "Printer SP", SP1-004 [Print Summary])
SMC - All (SP5-990-001)
SMC - Logging (SP5-990-004)
Printer driver settings used when the problem occurs
All data displayed on the screen (SC code, error code, and program address where the problem is logged.)
Image file which causes the problem, if possible