After Executing SP2-111-003
Result: "1" in SP2-194-007
Result: "2" or "3" (Line pattern detection failure) in SP2-194-010, -011, -012
Test pattern check |
Possible cause/Countermeasure |
---|---|
White image, Abnormal image, Low density |
|
Normal image, but with color registration errors |
|
After Executing SP2-111-003
Result: "1" in SP2-194-007
One of results: "5" (Out of adjustable range) in SP2-194-010, -011, -012.
Test pattern check |
Possible cause/Countermeasure |
---|---|
The main scan registrations of M, C, Y are shifted by more than ±15 mm from the main scan registration of K. |
|
The sub scan registrations of M, C, Y are shifted by more than ±20 mm from the sub scan registration of K. |
|
The main scan registration is shifted by more than ±0.66 mm, but only at the central area of the image on the output. |
|
The skew for M, C, Y is more than ±0.75 mm from the main scan registration of K |
|
Others |
|
After Executing SP2-111-003
Result: "1" in SP2-194-007
Result: "0" in SP2-194-010, -011, -012.
Test pattern check |
Possible cause/Countermeasure |
---|---|
Do SP2-111-001 or -002. |
After Executing SP2-111-001
Result: "1" in SP2-194-007
Result: "2" or "3" (Line pattern detection failure) in SP2-194-010, -011, -012
Test pattern check |
Possible cause/Countermeasure |
---|---|
White image, Abnormal image, Low density |
|
Normal image, but with color registration errors |
|
After Executing SP2-111-001
Result: "1" in SP2-194-007
Result: "5" (Out of adjustable range) in SP2-194-010, -011, -012
Test pattern check |
Possible cause/Countermeasure |
---|---|
Low image density on the output |
Do the forced process control (SP3-011-001) or supply some toner (SP3-015-xxx). |
The main scan registrations of M, C, Y are shifted by more than ±1.4 mm from the main scan registration of K. |
|
The sub scan registrations of M, C, Y are shifted by more than ±1.4mm from the sub scan registration of K. |
|
The main scan registration is shifted by more than ±0.66 mm, but only at the central area of the image on the output. |
|
The skew for M, C, Y is more than ± 0.75 mm from the main scan registration of K. – at the end of the scan line? |
|
Others |
|
After Executing SP2-111-001
Result: "0" in SP2-194-007
Result: No color registration errors in SP2-194-010, -011, -012
Test pattern check |
Possible cause/Countermeasure |
---|---|
The main scan registration of K is shifted. |
Adjust the value with SP2-101-001. |
The main scan length of K is shifted. |
Adjust the value with SP2-185-001. |
After Executing SP2-111-001
Result: "0" in SP2-194-007
Result: Color registration errors in SP2-194-010, -011, -012
Test pattern check |
Possible cause/Countermeasure |
---|---|
Low image density on the output |
Do the forced process control (SP3-011-001) or supply some toner (SP3-015-xxx). |
The main scan registration is shifted, but only at the central area of the image on the output. |
|
The main scan registrations of M, C, Y are shifted. |
|
The sub scan registrations of M, C, Y are shifted. |
|
The skew of M, C, Y is different. |
|
The sub scan lines are shifted. Shifted lines appear cyclically. |
|