Skip header
 

Before removing the old laser optics housing unit

Do the following settings before removing the laser optics housing unit. These are adjustments for skew adjustment motors in the laser optics housing unit.

  1. Plug in and turn on the main power switch of the copier.

  2. Enter the SP mode.

  3. Execute SP2220-001 to clear the L2 lens positioning motor setting for Magenta.

  4. Execute SP2220-002 to clear the L2 lens positioning motor setting for Cyan.

  5. Execute SP2220-003 to clear the L2 lens positioning motor setting for Yellow.

  6. Exit the SP mode.

  7. Turn off the main power switch and disconnect the power cord of the copier.