Skip header
 

Recovery procedure for no replacement preparation of laser optics housing unit

If you did not do the procedure in ‘Before removing the old laser optics housing’ before removing the old laser optics housing unit, you must do the following.

  1. Turn off the main power switch and disconnect the power cord of the copier.

  2. Remove the left cover and harness cover bracket (see the following "Removing the old laser optics housing unit")

    d088r610.jpg

  3. Disconnect the harness [A] of the skew correction motor.

  4. Do steps 1 to 7 of "Before removing the old laser optics housing unit".

  5. Connect the harness [A] and reinstall the harness bracket and left cover.

  6. Plug in and turn on the main power switch.