ConditionResolution
Execute Filling Liquid Extraction 1 (SP2-012-002) cannot be executed.Make sure that ink cartridges with the ink replacement jigs are set and the lock lever fully rises.
Executing "7" in SP2-012-002 is failed.Make sure that the lock lever of ink cartridges rises.
Execute Ink Filling (SP2-012-003) cannot be executed.Check the all eight ink cartridges are set.
Executing "7" in SP2-012-003 is failed.

Make sure that ink cartridges are inserted correctly and the lock lever of ink cartridges rises.

Execute Air Purge (Operating) (SP2-012-005) cannot be executed.Make sure that the port cover opens, and then retry Execute Air Purge (Flag Rewriting) (SP2-012-004).
Executing "1 or 2 or 4" in SP2-012-005 is failed.

Make sure that ink cartridges are inserted correctly.

Make sure that the lock lever of ink cartridges rises.

Make sure that the port cover opens.

Fully Automated Cleaning (SP2-100-003) cannot be executed.Make sure that the content of waste ink bottle is 0 %.
Proceeding sequence has stopped. (For example, front cover open)

Do the procedure according to the proceed administration.

If air purge needs to do, execute Execute Air Purge (Flag Rewriting) (SP2-012-004).

Waste ink bottle has become full.Repeatedly sequence failure results in many waste ink counts. Adjust the waste ink quantity to the amount you check visually.
Missing nozzle cannot be solved.Refer to "Requests for Daily Care and Maintenance", User Manual.
Run out of flushing liquid is displayed.Make sure that the lock lever of ink cartridges rises.
An error occurs while discharging the filling liquid or filling the ink.Make sure that the lock lever of ink cartridges rises.