What You Need
PartsQ'tyNote
Displacement liquid cartridge8 
Ink replacement jigs8 
Tubes4Only used in case of 4C+W -> 4C
Sealing materials for channel4Only used in case of 4C -> 4C+W
Cleaning When Changing the Color

The Flow of Full Auto Cleaning

No. 
1Set 4C cartridges, a flushing cartridge, a cleaning cartridge, and then turn the power on.
2Empty the waste ink bottle.
3Set the waste ink count to 0. (SP7-962-012)
4

Press full auto cleaning. (SP2-100-003)

To execute the SP, select "7" for all heads. 

5Remove the cartridge.
6Set the jig used for discharging liquid, set the cartridge again, and then close the cartridge lock.
7

Discharge the filling liquid. (SP2-012-002)

To execute the SP, select "7" for all heads. 

8Remove the jig used for discharging liquid.
9Set the displacement liquid cartridge, and then close the cartridge lock.
10

Fill the liquid. (SP2-012-003)

To execute the SP, select "7" for all heads.

11Remove the cartridge.
12Set the jig used for discharging liquid, set the cartridge again, and then close the cartridge lock.
13

Discharge liquid again. (SP2-012-002)

To execute the SP, select "7" for all heads. 

14Remove the jig used for discharging liquid.
15Set the displacement liquid cartridge, and then close the cartridge lock.
16

Fill the liquid again. (SP2-012-003)

To execute the SP, select "7" for all heads.

17

Rewrite the air purge flag. (SP2-012-004)

To execute the SP, select "7" for all heads. 

18Open the front cover, open the air purge port of H1, set the tray, and then close the front cover.
19

Perform air purge for H1. (SP2-012-005)

To execute the SP, select "1" for head 1.

20Open the front cover, close the air purge port of H1, remove the tray, and then close the front cover.
21

Perform head cleaning for H1. (SP2-010-001)

To execute the SP, select "1" for head 1.

22Open the front cover, open the air purge port of H2, set the tray, and then close the front cover.
23

Perform air purge for H2. (SP2-012-005)

To execute the SP, select "2" for head 2.

24Open the front cover, close the air purge port of H2, remove the tray, and then close the front cover.
25

Perform head cleaning for H2. (SP2-010-001)

To execute the SP, select "2" for head 2.

26Open the front cover, open the air purge port of H3, set the tray, and then close the front cover.
27

Perform air purge for H3. (SP2-012-005)

To execute the SP, select "4" for head 3.

28Open the front cover, close the air purge port of H3, remove the tray, and then close the front cover.
29

Perform head cleaning for H3. (SP2-010-001)

To execute the SP, select "4" for head 3.

When you cannot perform this procedure normally, refer to "Troubleshooting Information When Performing Initial Filling and Full Auto Cleaning".