1. Remove the cure heater. (Cure Heater)
  2. Remove the post heater. (Post Heater)
  3. Remove the post guide plate. (Post Guide Plate)
  4. Remove the pre-heater. (Pre-heater)
    Remove the fixing screws of the platen adjustment bracket (Front side) [A].
    Loosen the screw [B] with a ratchet driver.
  5. Remove the fixing screws of the platen adjustment bracket (Rear side) [A].
    Loosen the screw [B] with a ratchet driver.
  6. Remove the ground cable [A].
  7. Open the print heater [A], and then disconnect the connectors and release the clamps.
    Remove the print heater [A].
  8. Remove the brackets [A] from the print heater [B].

    • The height of each bracket is adjusted in the factory setting.

      When removing brackets, assign number to each bracket and write them in the brackets so that each bracket can be reattached at the same position and direction.

    • When attaching the brackets, Make sure to use the screw [A] for the middle position of the bracket because the screw type is different from others.