Initial operation setting value: This setting manages the state of the machine and determines the machine operation when the machine is powered on.

SP2-012-001

Condition

Operation

0

Normal

The machine performs auto maintenance.

1

When starting the initial filling

Auto maintenance does not start. This value is changed to 4 automatically when you execute SP2-012-002.

4

During initial filling

Auto maintenance does not start. This value is changed to 0 automatically when the last cleaning is completed.

5

During full auto cleaning

Auto maintenance does not start. Only a filling liquid cartridge can be installed. This value is changed to 9 when the last cleaning is completed.

6

During replacing print heads

Auto maintenance does not start. This value is changed to 6 by executing SP reset when you replace the print head, and then changed to 0 when the long air purge is completed.

9

Shipping

Auto maintenance does not start. This value is set when the machine is shipped.