This PCB works as the controller of the machine's printer functions and engine.

LED status
AddressColorLED status
LED1Yellow greenFlashing: Engine is functioning normally.
Unlit/Lit: Other than the above
LED3RedLit: +5 VX input
Unlit: Other than the above
LED4RedLit: +5 V input
Unlit: Other than the above
LED5Yellow greenLit: +3.3 V input
Unlit: Other than the above
LED6RedLit: +5 VE input
Unlit: Other than the above
LED7Yellow greenLit: Other than the described below.
Unlit: CTL is functioning normally.
Fuse condition
NameRatingConnected toWhen fuse is blown
CauseError display
FU10.5AREG1 (+5V -> +3.3V)PCB malfunctionSC display
FU20.5AIC19:DCDC (+5V -> +1.2V)PCB malfunctionSC display
FU31ACN217
Connected to SDCU (Vodka)
PCB malfunction, Ground fault of a cable-
FU41ACN216
Connected to SDCU (HORUS)
PCB malfunction
Ground fault of a cable
-
FU50.5AIC25:DCDC (+5V -> +1.1V)PCB malfunctionSC display
FU61.5ACN216
Connected to SDCU (HORUS)
PCB malfunction
Ground fault of a cable
-
FU70.5AIC34:Power IC for DDR3PCB malfunctionSC display
FU80.5AIC46:DCDC (+5 VX -> +1.8VE)PCB malfunctionMachine does not start normally, operation panel frozen
FU90.5AIC43: Power IC for DDR4PCB malfunctionMachine does not start normally, operation panel frozen
FU101.5ACN214
Connected to the operation panel
PCB malfunction, Ground fault of a cableOperation panel does not work
FU110.5AIC48:DCDC (+5V -> 1.8V)PCB malfunctionSC display
FU120.5AIC49:Power switch IC (+5VX -> +5VE)PCB malfunctionMachine does not start normally, operation panel frozen
FU130.5AREG2 (+5V -> +2.5V)PCB malfunctionSC display
FU140.65AREG3 (+5VX -> +2.5VE)PCB malfunctionMachine does not start normally, operation panel frozen
FU150.65AIC58:DCDC (+5VX -> 1.05VE)PCB malfunctionMachine does not start normally, operation panel frozen
FU161.5APCB (Reset circuit etc.)PCB malfunctionSC display
FU171.5AIC40
IC114:Reset IC
Power controller IC
PCB malfunctionMachine does not start normally
FU180.5AIC64:DCDC (+5VX -> 1.0VE)PCB malfunctionMachine does not start normally, operation panel frozen
FU190.5AREG4 (+5VX -> +3.3VE)PCB malfunctionMachine does not start normally, operation panel frozen
FU200.75ACN201
Connected to SD card
PCB malfunctionSD card is not recognized.
FU210.5ACN218
Carriage Home Position Sensor
Sub Scan Encoder Sensor
PCB malfunction, Ground fault of a cable, Sensor/switch malfunctionSC display, Cover open/close condition not recognized