The cure heater [A] consists of two infrared heaters which heat the surface of the media with infrared rays. The temperatures of both heaters are controlled uniformly. The reflector [B] reflects the infrared rays of the cure heater so that the media is heated by both the direct rays and reflected rays. The reflector also prevents the infrared rays from directly hitting the external covers. The dry curing fans [C] eject heat and vapor from the inside of the machine and cools the reflector.

  • Thermopile [D]
    Detects the temperature of the surface of the media to control the heater temperature.
  • Thermistor [E]/Thermostat [F]
    Detects the temperature of the reflector. When the temperature is 100 °C or higher, the thermostat breaks and physically turns off the power of the heater. This makes the possibility of fuming from the media as little as possible.

    SP No.NameDefaultRange
    SP1-108-001Cure Heater Upper Limit: Limit Temperature67 °C50 - 80 °C

Target Temperature

The target temperature of each heater is controlled by the RIP or SP. The machine compares the temperature detected by the thermopile and the target temperature, and controls the temperature by turning the heater ON/OFF.

  • Target temperature
    Post heater (2) + A °C
  • SP setting

    Temperature SettingSP No.NameDefaultRange
    A*1SP1-100-009Cure Heater Temp. Setting: Cure Heater Temp. Setting0 °C25 °C

    *1 Temperature is kept at the temperature specified by the RIP which is given priority. It is kept at the temperature specified in SP mode when the RIP does not specify the temperature.