Address | Color | LED Status |
---|---|---|
LED1 | Red | Lit: Emergency stop has occurred. Unlit: Emergency stop has not occurred. |
LED2 | Yellow | Lit: Internal warning has occurred. Unlit: Internal warning has not occurred. |
LED9 | Green | Lit: IC17 PLL lock complete Unlit: IC17 PLL lock incomplete |
LED10 | Orange | Lit: +5V ON Unlit: OFF |
LED11 | Orange | Lit: +3.3V ON Unlit: OFF |
LED12 | Orange | Lit: OFF Unlit: +24VS ON |
LED13 | Orange | Lit: OFF Unlit: +24VH ON |
LED14 | Orange | Lit: OFF Unlit: +35V ON |
LED15 | Green | Lit: IC17, 21 Configuration incomplete Unlit: IC17, 21 Configuration complete |
LED16 | Green | Lit: IC17 CLK Input OK Unlit: IC17 CLK Input NG |
LED17 | Orange | Lit: +35V_VCOM ON Unlit: OFF |
LED18 | Orange | Lit: +35VH ON Unlit: OFF |
Fuse condition
Name | Rating | Connected to | When fuse is blown | |
---|---|---|---|---|
Cause | Error display | |||
FU1 | 0.3A | CN106-111 | Print Head malfunction, Ground fault of ribbon cable | SC display |
FU2 | 0.5A | PCB (REG5) | PCB malfunction | SC display |
FU3 | 0.75A | Carriage cooling fan 1, 3 | PCB malfunction, Fan malfunction, Ground fault of a cable | SC display |
FU4 | 0.75A | Carriage cooling fan 2 | PCB malfunction, Fan malfunction, Ground fault of a cable | SC display |
FU5 | 4A | PCB 5V | PCB malfunction, Carriage hardware malfunction, Ground fault of a cable | SC display |
FU6 | 0.5A | PCB (IC12) | PCB malfunction | SC display |
FU7 | 0.75A | CN110 | PCB malfunction, Print Head malfunction, Ground fault of ribbon cable | SC display |
FU8 | 0.75A | CN108 | PCB malfunction, Print Head malfunction, Ground fault of ribbon cable | SC display |
FU9 | 0.75A | CN106 | PCB malfunction, Print Head malfunction, Ground fault of ribbon cable | SC display |
FU10 | 0.75A | CN116 | PCB malfunction, Supply solenoid 1/2 malfunction, Ground fault of a cable | SC display |
FU11 | 0.75A | CN116 | PCB malfunction, Supply solenoid 3/4 malfunction, Ground fault of a cable | SC display |
FU12 | 0.5A | CN112, CN106-111 | PCB malfunction, Print Head malfunction, Ground fault of ribbon cable | SC display |
FU13 | 7A | CN111 | PCB malfunction, Print Head malfunction, Ground fault of ribbon cable | SC display |
FU14 | 7A | CN111 | PCB malfunction, Print Head malfunction, Ground fault of ribbon cable | SC display |
FU15 | 7A | CN110 | PCB malfunction, Print Head malfunction, Ground fault of ribbon cable | SC display |
FU16 | 7A | CN110 | PCB malfunction, Print Head malfunction, Ground fault of ribbon cable | SC display |
FU17 | 7A | CN109 | PCB malfunction, Print Head malfunction, Ground fault of ribbon cable | SC display |
FU18 | 7A | CN109 | PCB malfunction, Print Head malfunction, Ground fault of ribbon cable | SC display |
FU19 | 0.5A | PCB (REG10) | PCB malfunction | SC display |
FU20 | 0.5A | PCB (REG7) | PCB malfunction | SC display |
FU21 | 0.65A | PCB (IC19) | PCB malfunction | SC display |
FU22 | 0.5A | PCB (REG1) | PCB malfunction | SC display |
FU23 | 0.5A | PCB (REG18) | PCB malfunction | SC display |
FU24 | 7A | CN106 | PCB malfunction, Print Head malfunction, Ground fault of ribbon cable | SC display |
FU25 | 7A | CN106 | PCB malfunction, Print Head malfunction, Ground fault of ribbon cable | SC display |
FU26 | 7A | CN107 | PCB malfunction, Print Head malfunction, Ground fault of ribbon cable | SC display |
FU27 | 7A | CN107 | PCB malfunction, Print Head malfunction, Ground fault of ribbon cable | SC display |
FU28 | 7A | CN108 | PCB malfunction, Print Head malfunction, Ground fault of ribbon cable | SC display |
FU29 | 7A | CN108 | PCB malfunction, Print Head malfunction, Ground fault of ribbon cable | SC display |
FU30 | 0.5A | PCB (IC102) | PCB malfunction | SC display |
FU31 | 0.65A | CN118 | CMOS image sensor malfunction, Ground fault of a cable | SC display |
FU32 | 0.65A | CN112,113,120,121 | Carriage rising sensor/Carriage jam sensor/Carriage LED/Paper edge sensor/Main scan encoder sensor malfunction, Ground fault of a cable | SC display |
FU33 | 0.65A | CN117 | Supply sensor (DFSB) malfunction 1 to 3, Ground fault of a cable | SC display |
FU34 | 0.65A | CN117 | Supply sensor (DFSB) malfunction 4 to 6, Ground fault of a cable | SC display |