1. Remove the screw [B] and loosen the screw [C] to move the media holding lever [A] towards the inside of the main unit.

    Since the screw [B] is a stepped screw, be careful not to reattach the wrong screw.

  2. Attach the brackets [B] to the left and right side of post heater [A]. (TAPPING SCREW:ROUND POINT:3X6)
    • Right side
    • Left side
  3. Attach the cure heater [A] to the main unit.
  4. Set the cure heater to the main unit by inserting the positioning pins [A] of the main unit into the pinholes of the cure heater.
    • Right side
    • Left side

      When attaching the cure heater to the main unit, make sure to prevent harnesses from being caught between them.

      After attaching the cure heater, check if harnesses are caught.

  5. Fix the cure heater. (TAPPING SCREW:4X8)
  6. Remove the tape [A] from the harnesses.

  7. Set the clamp attached to the harness to the hole [A], connect the connectors, and then route the harnesses as shown below.

    If the harness on the right side of the cure heater is slackened, set the clamp [A] to the hole [B] to fix the harness.

  8. Attach the right side plate [A] and the left side plate [B] to the cure heater. (TAPPING SCREW Round Point 3X6)

    Attach the right side plate and the left side plate to each position correctly because they are different in shape.